Unilateral tinnitus resulting from single-sided deafness can be treated with electrical stimulation via a CI. The outcomes of this pilot study demonstrate a new method for treatment of tinnitus in select subjects, perhaps an important new indication for cochlear implantation.
Background: While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL. Methods: This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada. Results: A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable. Conclusion: A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
Due to technological progress, videoconference interviews have become more and more common in personnel selection. Nevertheless, even in recent studies, interviewees received lower performance ratings in videoconference interviews than in face-to-face (FTF) interviews and interviewees held more negative perceptions of these interviews. However, the reasons for these differences are unclear. Therefore, we conducted an experiment with 114 participants to compare FTF and videoconference interviews regarding interview performance and fairness perceptions and we investigated the role of social presence, eye contact, and impression management for these differences. As in other studies, ratings of interviewees’ performance were lower in the videoconference interview. Differences in perceived social presence, perceived eye contact, and impression management contributed to these effects. Furthermore, live ratings of interviewees’ performance were higher than ratings based on recordings. Additionally, videoconference interviews induced more privacy concerns but were perceived as more flexible. Organizations should take the present results into account and should not use both types of interviews in the same selection stage.
Objective. To compare hearing and speech understanding between a new, nonskin penetrating Baha system (Baha Attract) to the current Baha system using a skin-penetrating abutment. Methods. Hearing and speech understanding were measured in 16 experienced Baha users. The transmission path via the abutment was compared to a simulated Baha Attract transmission path by attaching the implantable magnet to the abutment and then by adding a sample of artificial skin and the external parts of the Baha Attract system. Four different measurements were performed: bone conduction thresholds directly through the sound processor (BC Direct), aided sound field thresholds, aided speech understanding in quiet, and aided speech understanding in noise. Results. The simulated Baha Attract transmission path introduced an attenuation starting from approximately 5 dB at 1000 Hz, increasing to 20–25 dB above 6000 Hz. However, aided sound field threshold shows smaller differences and aided speech understanding in quiet and in noise does not differ significantly between the two transmission paths. Conclusion. The Baha Attract system transmission path introduces predominately high frequency attenuation. This attenuation can be partially compensated by adequate fitting of the speech processor. No significant decrease in speech understanding in either quiet or in noise was found.
Background: Clinical indicators are powerful tools to quantify the safety and quality of patient care. Their validity is often unclear and definitions extremely heterogeneous. As part of the International Standardised Endpoints in Perioperative Medicine (StEP) initiative, this study aimed to derive a set of standardised and valid clinical outcome indicators for use in perioperative clinical trials. Methods: We identified clinical indicators via a systematic review of the anaesthesia and perioperative medicine literature (PubMed/OVID, EMBASE, and Cochrane Library). We performed a three-stage Delphi consensus-gaining process that involved 54 clinicianeresearchers worldwide. Indicators were first shortlisted and the most suitable definitions for evaluation of quality and safety interventions determined. Indicators were then assessed for validity, reliability, feasibility, and clarity. Results: We identified 167 clinical outcome indicators. Participation in the three Delphi rounds was 100% (n¼13), 68% (n¼54), and 85% (n¼ 6), respectively. A final list of eight outcome indicators was generated: surgical site infection at 30 days, stroke within 30 days of surgery, death within 30 days of coronary artery bypass grafting, death within 30 days of
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.