Purpose of Review Robotic assistance systems for diagnosis and therapy have become technically mature and widely available. Thus, they play an increasingly important role in patient care. This paper provides an overview of the general concepts of robotically assisted surgical systems, briefly revisiting historical and current developments in the surgical robotics market and discussing current focus areas of research. Comprehensiveness cannot be achieved in this format, but besides the general overview, references to further readings and more comprehensive reviews with regard to particular aspects are given. Therefore, the work at hand is considered as an introductory paper into the topic and especially addresses investigators, researchers, medical device manufacturers, and clinicians, who are new to this field. Recent Findings The current research in Robotically Assisted Surgical Systems (RASS) increasingly uses established robotic platforms. To minimize the patient trauma while optimizing the dexterity of the surgeon, miniaturized instruments and semi-autonomous assistance functions are developed. To provide the surgeon with all necessary information in an adequate manner, novel imaging sensors as well as techniques for multimodal sensory feedback and augmented reality are investigated. The Surgical Data Science applies data management and processing approaches including machine learning on medical data to provide optimal, individualized and contextual support to the surgeon. Summary Robotic systems will significantly influence future patient care. Since they must fulfill manifold medical, technical, regulatory and economic requirements, their development calls for a close, active and interdisciplinary cooperation between stakeholders from hospitals, industry and science.
Minimally invasive robotic surgery copes with some disadvantages for the surgeon of minimally invasive surgery while preserving the advantages for the patient. Most commercially available robotic systems are telemanipulated with haptic input devices. The exploitation of the haptics channel, e.g., by means of Virtual Fixtures, would allow for an individualized enhancement of surgical performance with contextual assistance. However, it remains an open field of research as it is non-trivial to estimate the task context itself during a surgery. In contrast, surgical training allows to abstract away from a real operation and thus makes it possible to model the task accurately. The presented approach exploits this fact to parameterize Virtual Fixtures during surgical training, proposing a Shared Control Parametrization Engine that retrieves procedural context information from a Digital Twin. This approach accelerates a proficient use of the robotic system for novice surgeons by augmenting the surgeon’s performance through haptic assistance. With this our aim is to reduce the required skill level and cognitive load of a surgeon performing minimally invasive robotic surgery. A pilot study is performed on the DLR MiroSurge system to evaluate the presented approach. The participants are tasked with two benchmark scenarios of surgical training. The execution of the benchmark scenarios requires basic skills as pick, place and path following. The evaluation of the pilot study shows the promising trend that novel users profit from the haptic augmentation during training of certain tasks.
Purpose The robotic system CoFlex for kidney stone removal via flexible ureteroscopy (fURS) by a single surgeon (solo surgery, abbreviated SSU) is introduced. It combines a versatile robotic arm and a commercially available ureteroscope to enable gravity compensation and safety functions like virtual walls. The haptic feedback from the operation site is comparable to manual fURS, as the surgeon actuates all ureteroscope DoF manually. Methods The system hardware and software as well as the design of an exploratory user study on the simulator model with non-medical participants and urology surgeons are described. For each user study task both objective measurements (e.g., completion time) and subjective user ratings of workload (using the NASA-TLX) and usability (using the System Usability Scale SUS) were obtained. Results CoFlex enabled SSU in fURS. The implemented setup procedure resulted in an average added setup time of 341.7 ± 71.6 s, a NASA-TLX value of 25.2 ± 13.3 and a SUS value of 82.9 ± 14.4. The ratio of inspected kidney calyces remained similar for robotic (93.68 %) and manual endoscope guidance (94.74 %), but the NASA-TLX values were higher (58.1 ± 16.0 vs. 48.9 ± 20.1) and the SUS values lower (51.5 ± 19.9 vs. 63.6 ± 15.3) in the robotic scenario. SSU in the fURS procedure increased the overall operation time from 1173.5 ± 355.7 s to 2131.0 ± 338.0 s, but reduced the number of required surgeons from two to one. Conclusions The evaluation of CoFlex in a user study covering a complete fURS intervention confirmed the technical feasibility of the concept and its potential to reduce surgeon working time. Future development steps will enhance the system ergonomics, minimize the users’ physical load while interacting with the robot and exploit the logged data from the user study to optimize the current fURS workflow.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.