BACKGROUND AND PURPOSE:Growing evidence of the relationship between poor antiplatelet response and occurrence of clinical events elicited the need of monitoring the response which has not been part of our daily practice. We present our initial experience with a new point-of-care antiplateletfunction test (VerifyNow assay) in neurointerventional procedures.
BACKGROUND AND PURPOSE: Low-profile self-expandable stents were recently introduced for the treatment of wide-neck intracranial aneurysms. This study investigated the initial and midterm clinical and angiographic results of LEO Baby stent-assisted coiling in the treatment of wide-neck intracranial aneurysms.
BACKGROUND AND PURPOSE:Various techniques and materials have been used for the endovascular treatment of craniofacial high-flow arteriovenous vascular malformations, because their rarity precludes standardization of their treatment. The aim of this retrospective review is to assess Onyx as the primary embolic agent in the treatment of these vascular malformations.
Heat therapies such as hyperthermia and thermoablation are very promising approaches in the treatment of cancer. Compared with available hyperthermia modalities, magnetic fluid hyperthermia ͑MFH͒ yields better results in uniform heating of the deeply situated tumors. In this approach, fluid consisting of superparamagnetic particles ͑magnetic fluid͒ is delivered to the tumor. An alternating ͑ac͒ magnetic field is then used to heat the particles and the corresponding tumor, thereby ablating it. However, one of the most serious shortcomings of this technique is the unwanted heating of the healthy tissues. This results from the magnetic fluid diffusion from the tumor to the surrounding tissues or from incorrect localization of the fluids in the target tumor area. In this study, the authors demonstrated that by depositing appropriate static ͑dc͒ magnetic field gradients on the alternating ͑ac͒ magnetic fields, focused heating of the magnetic particles can be achieved. A focused hyperthermia system was implemented by using two types of coils: dc and ac coils. The ac coil generated the alternating magnetic field responsible for the heating of the magnetic particles; the dc coil was used to superimpose a static magnetic field gradient on the alternating magnetic field. In this way, focused heating of the particles was obtained in the regions where the static field was dominated by the alternating magnetic field. In vitro experiments showed that as the magnitude of the dc solenoid currents was increased from 0 to 1.8 A, the specific absorption rate ͑SAR͒ of the superparamagnetic particles 2 cm apart from the ac solenoid center decreased by a factor of 4.5, while the SAR of the particles at the center was unchanged. This demonstrates that the hyperthermia system is capable of precisely focusing the heat at the center. Additionally, with this approach, shifting of the heat focus can be achieved by applying different amounts of currents to individual dc solenoids. In vivo experiments were performed with adult rats, where magnetic fluids were injected percutaneously into the tails ͑with homogeneous fluid distribution inside the tails͒. Histological examination showed that, as we increased the dc solenoid current from 0.5 to 1.8 A, the total burned volume decreased from 1.6 to 0.2 cm 3 verifying the focusing capability of the system. The authors believe that the studies conducted in this work show that MFH can be a much more effective method with better heat localization and focusing abilities.
We present the long-term clinical and angiographic follow-up results of 100 consecutive intracranial aneurysms treated with Onyx liquid embolic system (MTI, Irvine, Calif.), either alone or combined with an adjunctive stent, in a single center. A total of 100 aneurysms in 94 patients were treated with endosaccular Onyx packing. Intracranial stenting was used adjunctively in 25 aneurysms including 19 during initial treatment and 6 during retreatment. All aneurysms except two were located in the internal carotid artery. Of the 100 aneurysms, 35 were giant or large/wide-necked, and 65 were small. Follow-up angiography was performed in all 91 surviving patients (96 aneurysms) at 3 and/or 6 months. Follow-up angiography was performed at 1, 2, 3, 4 and 5 years in 90, 41, 26, 6 and 2 patients, respectively. Overall, aneurysm recanalization was observed in 12 of 96 aneurysms with follow-up angiography (12.5%). All 12 were large or giant aneurysms, resulting in a 36% recanalization rate in the large and giant aneurysm group. One aneurysm out of 25 treated with the combination of a stent and Onyx showed recanalization. There was also no recanalization in the follow-up of small internal carotid artery aneurysms treated with balloon assistance only. At final follow-up, procedure- or device-related permanent neurological morbidity was present in eight patients (8.3%). There were two procedure-related and one disease-related (subarachnoid hemorrhage) deaths (mortality 3.2%). Delayed spontaneous asymptomatic occlusion of the parent vessel occurred in two patients, detected on routine follow-up. Onyx provides durable aneurysm occlusion with parent artery reconstruction resulting in perfectly stable 1-year to 5-year follow-up angiography both in small aneurysms treated with balloon assistance only (0% recanalization rate) and large or giant aneurysms treated with stent and Onyx combination (4% recanalization rate). Endosaccular Onyx packing with balloon assistance may not be adequate for stable long-term results in those with a large or giant aneurysm. However, the recanalization rate of 36% in these aneurysms is better than the reported results with other techniques, i.e., coils with or without adjunctive bare stents.
A complex case of carotid-cavernous fistula was treated transvenously by injection of ethyl vinyl alcohol co-polymer into the cavernous sinus after an unsuccessful embolization attempt with detachable coils and liquid adhesive agents. There were no complications. At 3 months the patient's symptoms had resolved completely, and a control angiogram revealed persistent occlusion. The physical properties of ethyl vinyl alcohol polymer justify further investigation of this agent for the treatment of carotid-cavernous fistula.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.