Electrospray ionization (ESI) is a dynamic process that, when coupled with mass spectrometry (MS), serves as an invaluable tool for analysis of biomolecules. Our group, as well as others, has observed that there is a bias in signal intensity for one strand of a PCR amplicon over the complementary strand in an ESI mass spectrum. In this report, we have investigated the contributions of hydrophobicity and free energy of solvation to relative signal intensities in ESI-MS spectra of nucleic acids. We developed approaches for predicting which strand of the PCR amplicon will be the most intense: one based on a rate equation for calculating ion flux using values from the literature for hydrophobicity and free energy of solvation and the other based on the percentage of the relatively hydrophilic guanines present in the strand. A trend in signal intensity for deoxyribonucleotide triphosphates, oligonucleotides, and PCR amplicons was observed that was consistent with our model. On the basis of the observation that increased hydrophobicity correlates with greater signal intensity, we selectively enhanced the signal intensity of a 20-mer with the addition of an alkyl chain to the 5' terminus, which subsequently improved the limit of detection to 1 nM, an improvement by 1 order of magnitude. This was extended to a 53-bp PCR amplicon by modifying one primer with the hydrophobic moiety, which resulted in a 16% increase in signal intensity. We capitalized on this result to determine allele frequencies from pooled DNA for single-nucleotide polymorphisms down to 1%.
ORCID IDs: 0000-0002-5392-0076 (J.P.W.); 0000-0001-7120-4690 (Y.-C.L.); 0000-0002-3021-3942 (J.D.); 0000-0002-7152-9601 (V.L.C.)As a step toward predictive modeling of flux through the pathway of monolignol biosynthesis in stem differentiating xylem of Populus trichocarpa, we discovered that the two 4-coumaric acid:CoA ligase (4CL) isoforms, 4CL3 and 4CL5, interact in vivo and in vitro to form a heterotetrameric protein complex. This conclusion is based on laser microdissection, coimmunoprecipitation, chemical cross-linking, bimolecular fluorescence complementation, and mass spectrometry. The tetramer is composed of three subunits of 4CL3 and one of 4CL5. 4CL5 appears to have a regulatory role. This protein-protein interaction affects the direction and rate of metabolic flux for monolignol biosynthesis in P. trichocarpa. A mathematical model was developed for the behavior of 4CL3 and 4CL5 individually and in mixtures that form the enzyme complex. The model incorporates effects of mixtures of multiple hydroxycinnamic acid substrates, competitive inhibition, uncompetitive inhibition, and self-inhibition, along with characteristic of the substrates, the enzyme isoforms, and the tetrameric complex. Kinetic analysis of different ratios of the enzyme isoforms shows both inhibition and activation components, which are explained by the mathematical model and provide insight into the regulation of metabolic flux for monolignol biosynthesis by protein complex formation.
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) has rapidly established a prominent role in proteomics because of its unparalleled resolving power, sensitivity and ability to achieve high mass measurement accuracy (MMA) simultaneously. However, space-charge effects must be quantitatively, routinely, and confidently corrected because they are known to profoundly influence MMA. We argue that the most effective way to account for space-charge effects is to introduce an internal mass calibrant (IMC) using a dual electrospray ionization (ESI) source where the IMC is added from a separate ESI emitter. The major disadvantage of our initial dual ESI source to achieve high MMA, and arguably the only one, was the time required to switch between the analyte emitter and IMC emitter (i.e., >300 ms). While this "switching time" was acceptable for direct infusion experiments, it did not lend itself to high-throughput applications or when conducting on-line liquid separations. In this report, we completely redesigned the dual ESI source and demonstrate several key attributes. First, the new design allows for facile alignment of ESI emitters, undetectable vibration, and the ability to extend to multiple emitters. Second, the switching time was reduced to <50 ms, which allowed the analyte and IMC to be accumulated "simultaneously" in the external ion reservoir and injected as a single ion packet into the ion cyclotron resonance cell, eliminating the need for a separate accumulation and ion injection event for the IMC. Third, by using a high concentration of the IMC, the residence time on this emitter could be reduced to approximately 80 ms, allowing for more time spent accumulating analyte ions of significantly lower concentration. Fourth, multiplexed on-line separations can be carried out providing increased throughput. Specifically, the new dual ESI source has demonstrated its ability to produce a stable ion current over a 45-min time period at 7 T resulting in mass accuracies of 1.08 ppm +/- 0.11 ppm (mean +/- confidence interval of the mean at 95% confidence; N = 160). In addition, the analysis of a tryptic digest of apomyoglobin by nanoLC-dual ESI-FT-ICR afforded an average MMA of -1.09 versus -74.5 ppm for externally calibrated data. Furthermore, we demonstrate that the amplitude of a peptide being electrosprayed at 25 nM can be linearly increased, ultimately allowing for dynamic analyte/IMC abundance modulation. Finally, we demonstrate that this source can reliably be used for multiplexing measurements from two (eventually more) flow streams.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.