In six German Shepherds dogs, GnRH agonist implants (Deslorelin) were inserted subcutaneously one month after histological confirmation of benign prostatic hyperplasia (BPH). Prostatic volume (PV), characteristics of ejaculate, serum testosterone concentrations and Doppler parameters of prostatic and subcapsular arteries were detected at different time intervals, for 6 month. The prostatic volume showed a significantly reduction starting at day 37. The decrease in sperm concentration, motility and increase in morphological abnormal sperm were observed from day 22 to day 37, when it was no longer possible to obtain the ejaculate. The values of peak systolic velocity and end-diastolic velocity in prostatic and subcapsular arteries showed from day 11 a gradual decrease, significant at day 22 until day 37 and reaching the lowest values at day 52 until the end of observation. The power Doppler pixel intensity of both arteries showed a gradual decrease from day 5 until day 52. In particular, a significant decrease was observed for both arteries from day 11. Testosterone serum concentration decreased to undetectable levels by day 11 until the end of the observations. All these Doppler parameters and testosterone values were positively correlated with the prostatic volume. Furthermore, testosterone values were positively correlated with peak systolic velocity, end diastolic velocity and pixel numbers. The use of implants containing GnRH analogues, even in asymptomatic subjects, is effective for the control of BPH and the application of Doppler exam of prostatic blood flow represent an non-invasive tool for monitoring the response of medical treatment.
This study was carried out with the objectives to test the differences in the haemodynamic characteristics of the prostatic artery in normal and benign prostatic hyperplasia (BPH)-affected dogs using Doppler ultrasonography. In sixteen male German shepherd dogs, prostatic volume was detected and prostatic biopsy was performed. The prostatic artery blood flow parameters determined were as follows: peak systolic velocity (PSV), end diastolic velocity (EDV), Resistive Index (RI) and Pulsatility Index. The power Doppler mode was used for colour flow mapping of the prostatic artery. In PW mode at marginal locations, the waveforms recorded showed a continuous pattern typical of the high-resistance vessels, while in subcapsular locations, the waveforms recorded were continuous characteristic of the low-resistance vessel. Peak systolic velocity and EDV in both locations were significantly higher in BPH group (p < 0.001) than normal group (p < 0.05). Pixel number in BPH group in both locations was significantly higher (p < 0.05) compared to the normal group. This study shows that Doppler ultrasonography represents a valid and non-invasive method for the characterization of the blood flow in the prostatic artery in dogs affected with BPH. Moreover, statistically significant differences of blood flow velocities in prostatic artery in normal and BPH-affected dogs were detected. The RI was not able to differentiate normal dogs from dogs affected by BPH and therefore is not a parameter usable for diagnostic purposes, while Power Doppler could represent an additional diagnostic tool.
The aim of this work was to evaluate the hemodynamic changes in the utero-placental arterial vessels in rabbits (Orictolagus cuniculus) throughout pregnancy as well as those in the umbilical cord, aorta, and caudal vena cava of fetuses to establish their normal reference ranges for systolic peak velocity (SPV), end diastolic velocity (EDV), pulsatility index (PI), and resistance index (RI). The blood flow waveforms were monitored every 4 d in 10 rabbits from Day 10 of pregnancy onward by means of color and pulsed wave Doppler ultrasonography using a 5.5-7.5 MHz microconvex transabdominal probe. The utero-placental blood flow was characterized by steep increases and decrease in the SPV with a slow diastolic wave and relatively high EDV, whereas that of the umbilical artery was discontinuous until Day 22 of pregnancy, when a diastolic waveform was also detectable. From Day 10 to 22 of pregnancy, the fetal aorta blood flow was discontinuous, but thereafter a diastolic peak was measurable. The blood flow of the fetal caudal vena cava was characterized by a systolic peak followed by a small diastolic peak. Throughout the gestation, the SPV and the EDV of maternal and fetal vessels increased (alpha<0.05), whereas the PI and the RI decreased (alpha<0.05), except for the utero-placental vessels. This work confirms that the rabbit could also be a valid experimental animal model to study, by Doppler ultrasonography, functional hemodynamic changes of the fetuses and placenta vessels in both normal and pathophysiologic conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.