Background Fall-related injuries exert an enormous health burden on older adults in long-term care (LTC). Softer landing surfaces, such as those provided by low-stiffness “compliant” flooring, may prevent fall-related injuries by decreasing the forces applied to the body during fall impact. Our primary objective was to assess the clinical effectiveness of compliant flooring at preventing serious fall-related injuries among LTC residents. Methods and findings The Flooring for Injury Prevention (FLIP) Study was a 4-year, randomized superiority trial in 150 single-occupancy resident rooms at a single Canadian LTC site. In April 2013, resident rooms were block randomized (1:1) to installation of intervention compliant flooring (2.54 cm SmartCells) or rigid control flooring (2.54 cm plywood) covered with identical hospital-grade vinyl. The primary outcome was serious fall-related injury over 4 years that required an emergency department visit or hospital admission and a treatment procedure or diagnostic evaluation in hospital. Secondary outcomes included minor fall-related injury, any fall-related injury, falls, and fracture. Outcomes were ascertained by blinded assessors between September 1, 2013 and August 31, 2017 and analyzed by intention to treat. Adverse outcomes were not assessed. During follow-up, 184 residents occupied 74 intervention rooms, and 173 residents occupied 76 control rooms. Residents were 64.3% female with mean (SD) baseline age 81.7 (9.5) years (range 51.1 to 104.6 years), body mass index 25.9 (7.7) kg/m 2 , and follow-up 1.64 (1.39) years. 1,907 falls were reported; 23 intervention residents experienced 38 serious injuries (from 29 falls in 22 rooms), while 23 control residents experienced 47 serious injuries (from 34 falls in 23 rooms). Compliant flooring did not affect odds of ≥1 serious fall-related injury (12.5% intervention versus 13.3% control, odds ratio [OR]: 0.98, 95% CI: 0.52 to 1.84, p = 0.950) or ≥2 serious fall-related injuries (5.4% versus 7.5%, OR: 0.74, 95% CI: 0.31 to 1.75, p = 0.500). Compliant flooring did not affect rate of serious fall-related injuries (0.362 versus 0.422 per 1,000 bed nights, rate ratio [RR]: 1.04, 95% CI: 0.45 to 2.39, p = 0.925; 0.038 versus 0.053 per fall, RR: 0.81, 95% CI: 0.38 to 1.71, p = 0.560), rate of falls with ≥1 serious fall-related injury (0.276 versus 0.303 per 1,000 bed nights, RR: 0.97, 95% CI: 0.52 to 1.79, p = 0.920), or time to first serious fall-related injury (0.237 versus 0.257, hazard ratio [HR]: 0.92, 95% CI: 0.52 to 1.62, p = 0.760). Compliant flooring did not affect any secondary outcome in this study. Study limitations included the following: findings were specific to 2.54 cm SmartCells compliant flooring installed in LTC resident rooms, standard fall and injury prevention interventions were in us...
ABSTRACT:The relationships between non-contact anterior cruciate ligament injuries and the underlying biomechanics are still unclear, despite large quantities of academic research. The purpose of this research was to study anterior cruciate ligament strain during jump landing by investigating its correlation with sagittal plane kinetic/kinematic parameters and by creating an empirical model to estimate the maximum strain. Whole-body kinematics and ground reaction forces were measured from seven subjects performing single leg jump landing and were used to drive a musculoskeletal model that estimated lower limb muscle forces. These muscle forces and kinematics were then applied on five instrumented cadaver knees using a dynamic knee simulator system. Correlation analysis revealed that higher ground reaction force, lower hip flexion angle and higher hip extension moment among others were correlated with higher peak strain (p < 0.05). Multivariate regression analyses revealed that intrinsic anatomic factors account for most of the variance in strain. Among the extrinsic variables, hip and trunk flexion angles significantly contributed to the strain. The empirical relationship developed in this study could be used to predict the relative strain between jumps of a participant and may be beneficial in developing training programs designed to reduce an athlete's risk of injury. Keywords: ACL; muscle force; musculoskeletal modeling; risk factor; knee injuryDespite the large quantity of research available on non-contact anterior cruciate ligament (ACL) injuries, the contributing factors and their relative contribution to the injury is still under debate. 1 This is in part due to the difficulty of measuring ACL strain in vivo 2 and inability to relate the ACL strain to the possible contributing factors. Unless the relationships between body kinematics, muscle forces and ACL strain is understood, the mechanism of ACL injury will remain unclear. Understanding the mechanics behind these injuries is crucial for injury prevention. Injuries may be prevented if screening and training programs are created for athletes who display at-risk mechanics. [3][4][5] Sagittal plane factors have been identified as important contributors to ACL injury mechanisms. [6][7][8] In addition to these extrinsic biomechanical factors, ACL strain is also dependent on a number of intrinsic anatomic factors such as tibial slope, 9,10 femoral notch width, 11 and ACL size. 12 Although these factors are known correlates with ACL strain, the relative contribution of extrinsic biomechanical and intrinsic anatomical factors is unknown.Pioneering efforts have been made to understand the relationship between knee kinematics, kinetics and ACL strain by surgically placing strain gauges on ligaments in live participants. 13 However, for ethical reasons, such approaches have not been extended to activities that are dynamic in nature. Numerical modelling approaches have been used to address this gap [14][15][16] ; however, model validation is complicated by the lack...
Introduction Hip protectors represent a promising strategy for preventing fall-related hip fractures. However, clinical trials have yielded conflicting results due, in part, to lack of agreement on techniques for measuring and optimizing the biomechanical performance of hip protectors as a prerequisite to clinical trials. Methods In November 2007, the International Hip Protector Research Group met in Copenhagen to address barriers to the clinical effectiveness of hip protectors. This paper represents an evidence-based consensus statement from the group on recommended methods for evaluating the biomechanical performance of hip protectors. Results and conclusions The primary outcome of testing should be the percent reduction (compared with the unpadded condition) in peak value of the axial compressive force applied to the femoral neck during a simulated fall on the greater trochanter. To provide reasonable results, the test system should accurately simulate the pelvic anatomy, and the impact velocity (3.4 m/s), pelvic stiffness (acceptable range: 39–55 kN/m), and effective mass of the body (acceptable range: 22–33 kg) during impact. Given the current lack of clear evidence regarding the clinical efficacy of specific hip protectors, the primary value of biomechanical testing at present is to compare the protective value of different products, as opposed to rejecting or accepting specific devices for market use.
A participatory ergonomics programme was implemented in an automotive parts manufacturing factory. An ergonomics change team was formed composed of members from management and the organized labour union. It was hypothesized that the physical change projects implemented as part of this process would result in decreased worker exposures to peak and cumulative physical demands and reduced worker perceptions of physical effort and pain severity. A quasi-experimental design was employed, utilizing a sister plant in the corporation as a referent group. A longitudinal questionnaire approach was used to document pre-post changes in worker perceptions. In general, the physical change projects were rated as improvements by workers and were successful at reducing peak and/or cumulative mechanical exposures. However, there were few systematic changes in perceived effort or pain severity levels. Explanations include the confounding effects of differential production rate and staffing changes at the intervention and referent plants and/or insufficient overall intervention intensity due to a relatively short intervention period, plant and team ambivalence towards the process and the low overall impact on exposure of the particular changes implemented.
BackgroundCompliant flooring, broadly defined as flooring systems or floor coverings with some level of shock absorbency, may reduce the incidence and severity of fall-related injuries in older adults; however, a lack of synthesized evidence may be limiting widespread uptake.MethodsInformed by the Arksey and O’Malley framework and guided by a Research Advisory Panel of knowledge users, we conducted a scoping review to answer: what is presented about the biomechanical efficacy, clinical effectiveness, cost-effectiveness, and workplace safety associated with compliant flooring systems that aim to prevent fall-related injuries in healthcare settings? We searched academic and grey literature databases. Any record that discussed a compliant flooring system and at least one of biomechanical efficacy, clinical effectiveness, cost-effectiveness, or workplace safety was eligible for inclusion. Two independent reviewers screened and abstracted records, charted data, and summarized results.ResultsAfter screening 3611 titles and abstracts and 166 full-text articles, we included 84 records plus 56 companion (supplementary) reports. Biomechanical efficacy records (n = 50) demonstrate compliant flooring can reduce fall-related impact forces with minimal effects on standing and walking balance. Clinical effectiveness records (n = 20) suggest that compliant flooring may reduce injuries, but may increase risk for falls. Preliminary evidence suggests that compliant flooring may be a cost-effective strategy (n = 12), but may also result in increased physical demands for healthcare workers (n = 17).ConclusionsIn summary, compliant flooring is a promising strategy for preventing fall-related injuries from a biomechanical perspective. Additional research is warranted to confirm whether compliant flooring (i) prevents fall-related injuries in real-world settings, (ii) is a cost-effective intervention strategy, and (iii) can be installed without negatively impacting workplace safety. Avenues for future research are provided, which will help to determine whether compliant flooring is recommended in healthcare environments.
Prophylactic knee brace could reduce the strain in the anterior cruciate ligament of high-risk subjects during drop-landing through altered muscle firing pattern associated with brace wear. This could help reduce the anterior cruciate ligament injury risk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.