Extracorporeal membrane oxygenation (ECMO) is used in critical care to manage patients with severe respiratory and cardiac failure. ECMO brings blood from a critically ill patient into contact with a non-endothelialized circuit which can cause clotting and bleeding simultaneously in this population. Continuous systemic anticoagulation is needed during ECMO. The membrane oxygenator, which is a critical component of the extracorporeal circuit, is prone to significant thrombus formation due to its large surface area and areas of low, turbulent, and stagnant flow. Various surface coatings, including but not limited to heparin, albumin, poly(ethylene glycol), phosphorylcholine, and poly(2-methoxyethyl acrylate), have been developed to reduce thrombus formation during ECMO. The present work provides an up-to-date overview of anti-thrombogenic surface coatings for ECMO, including both commercial coatings and those under development. The focus is placed on the coatings being developed for oxygenators. Overall, zwitterionic polymer coatings, nitric oxide (NO)-releasing coatings, and lubricant-infused coatings have attracted more attention than other coatings and showed some improvement in in vitro and in vivo anti-thrombogenic effects. However, most studies lacked standard hemocompatibility assessment and comparison studies with current clinically used coatings, either heparin coatings or nonheparin coatings. Moreover, this review identifies that further investigation on the thrombo-resistance, stability and durability of coatings under rated flow conditions and the effects of coatings on the function of oxygenators (pressure drop and gas transfer) are needed. Therefore, extensive further development is required before these new coatings can be used in the clinic.
All human cells are coated by a surface layer of proteoglycans, glycosaminoglycans (GAGs) and plasma proteins, called the glycocalyx. The glycocalyx transmits shear stress to the cytoskeleton of endothelial cells, maintains a selective permeability barrier, and modulates adhesion of blood leukocytes and platelets. Major components of the glycocalyx, including syndecans, heparan sulfate, and hyaluronan, are shed from the endothelial surface layer during conditions including ischaemia and hypoxia, sepsis, atherosclerosis, diabetes, renal disease, and some viral infections. Studying mechanisms of glycocalyx damage in vivo can be challenging due to the complexity of immuno-inflammatory responses which are inextricably involved. Previously, both static as well as perfused in vitro models have studied the glycocalyx, and have reported either imaging data, assessment of barrier function, or interactions of blood components with the endothelial monolayer. To date, no model has simultaneously incorporated all these features at once, however such a model would arguably enhance the study of vasculopathic processes. This review compiles a series of current in vitro models described in the literature that have targeted the glycocalyx layer, their limitations, and potential opportunities for further developments in this field.
Retroperitoneal haemorrhage is a rare but potentially life-threatening event. It may occur either spontaneously or secondary to percutaneous vascular access procedures, trauma, or ruptured aortic, iliac, or mesenteric aneurysms. As a result, the clinical presentation is variable. Computed tomography and/or angiography are vital for diagnosis. Management may range from conservative treatment for stable patients to emergency laparotomy or embolization for catastrophic haemorrhage. Direct percutaneous puncture of a deep intra-abdominal pseudoaneurysm is an accepted but infrequently performed technique due to a number of diagnostic and technical challenges. We describe the successful percutaneous transabdominal angioembolization of a superior mesenteric artery rupture in a 77-year-old woman with a large retroperitoneal haematoma. This was performed after a conventional femoral transarterial approach was unsuccessful.
Limb ischemia is a major complication associated with peripheral venoarterial extracorporeal membrane oxygenation (VA‐ECMO). The high velocity jet from arterial cannulae can cause “sandblasting” injuries to the arterial endothelium, with the potential risk of distal embolization and end organ damage. The aim of this study was to identify, for a range of clinically relevant VA‐ECMO cannulae and flow rates, any regions of peak flow velocity on the aortic wall which may predispose to vascular injury, and any regions of low‐velocity flow which may predispose to thrombus formation. A silicone model of the aortic and iliac vessels was sourced and the right external iliac artery was cannulated. Cannulae ranged from 15 to 21 Fr in size. Simulated steady state ECMO flow rates were instituted using a magnetically levitated pump (CentriMag pump). Adaptive particle image velocimetry was performed for each cannula at 3, 3.5, 4, and 4.5 L/min. For all cannulae, in both horizontal and vertical side hole orientations, the peak velocity on the aortic wall ranged from 0.3 to 0.45 m/s, and the regions of lowest velocity flow were 0.05 m/s. The magnitude of peak velocity flow on the aortic wall was not different between a single pair versus multiple pairs of side holes. Maximum velocity flow on the aortic wall occurred earlier at a lower pump flow rate in the vertical orientation of distal side holes compared to a horizontal position. The presence of multiple paired side holes was associated with fewer low‐velocity flow regions, and some retrograde flow, in the distal abdominal aorta compared to cannulae with a single pair of side holes. From this in vitro visualization study, the selection of a cannula design with multiple versus single pairs of side holes did not change the magnitude of peak velocity flow delivered to the vessel wall. Cannulae with multiple side holes were associated with fewer regions of low‐velocity flow in the distal abdominal aorta. Further in vivo studies, and ideally clinical data would be required to assess any correlation of peak velocity flows with incidence of vascular injury, and any low‐velocity flow regions with incidence of thrombosis.
Introduction Heart transplantation (HTx) is the primary therapy for end‐stage heart failure. For HTx, donor hearts are typically preserved on ice in a cooler (devoid of oxygen), termed cold static storage (CSS). CSS beyond 4 hrs increases the risk of primary graft dysfunction (PGD), the leading cause of early death post‐HTx. Hypothermic ex vivo perfusion (HEVP) of donor hearts allows oxygen delivery during preservation, and we hypothesise, may safely extend donor heart preservation time without increasing PGD risk. We sought to compare post‐HTx recipient survival, cardiac contractility, mitochondrial function, and injury following donor heart preservation by CSS (2 hrs) or HEVP (2 and 8 hrs). Methods Brain death was induced in donor sheep for 24 hrs, hearts were then preserved by a) CSS for 2 hrs (n=8), b) HEVP for 2 hrs (n=6), or c) HEVP for 8 hrs (n=7). Orthotopic HTx was performed in matched recipients, with progressive hemodynamic management and monitoring for 6 hrs post‐HTx. Recipient cardiac function was assessed by echocardiography, and troponin I levels were measured in plasma. Mitochondrial function, in vitro contractile responses to noradrenaline (trabeculae), and histopathological changes were determined in cardiac tissue collected at end‐study. Results All HEVP recipients survived to 6 hrs post‐HTx, compared to 6/8 CSS recipients. HEVP (2 and 8 hrs) recipients required less vasoactive support for adequate hemodynamic function, and exhibited reduced blood lactate levels compared to CSS. Post‐HTx cardiac function and troponin I levels were comparable between groups over time, however improved contractile responses to noradrenaline were observed in isolated trabeculae from 2 and 8 hr HEVP hearts. Cardiac mitochondrial function was similar between all groups, except for the 2 hrs HEVP left ventricle, where greater improvements in mitochondrial membrane potential generation were observed. Regardless of preservation technique, histological scores revealed widespread cardiac injury (e.g. myocytolysis and neutrophil infiltration). Conclusion Donor heart preservation by HEVP shows promising post‐HTx outcomes in comparison to CSS in a sheep HTx model. HEVP can be safely extended up to 8 hrs, without compromising post‐HTx recipient survival, cardiac contractile or mitochondrial function. HEVP may assist in overcoming limitations in preservation time associated with HTx, without increasing PGD risk. The Australian Non‐Ischemic Heart Preservation (NIHP) trial is currently assessing extended HEVP in clinical HTx (ACTRN12620000595910p).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.