Visualization of the SSN with US is better in the supraclavicular region as compared with the supraspinous fossa. The anatomic dissections confirmed that our novel supraclavicular SSN block technique is accurate.
We developed a geospatial model that calculates ambient high-frequency electromagnetic field (HF-EMF) strengths of stationary transmission installations such as mobile phone base stations and broadcast transmitters with high spatial resolution in the order of 1 m. The model considers the location and transmission patterns of the transmitters, the three-dimensional topography, and shielding effects by buildings. The aim of the present study was to assess the suitability of the model for exposure monitoring and for epidemiological research. We modeled time-averaged HF-EMF strengths for an urban area in the city of Basel as well as for a rural area (Bubendorf). To compare modeling with measurements, we selected 20 outdoor measurement sites in Basel and 18 sites in Bubendorf. We calculated Pearson's correlation coefficients between modeling and measurements. Chance-corrected agreement was evaluated by weighted Cohen's kappa statistics for three exposure categories. Correlation between measurements and modeling of the total HF-EMF strength was 0.67 (95% confidence interval (CI): 0.33-0.86) in the city of Basel and 0.77 (95% CI: 0.46-0.91) in the rural area. In both regions, kappa coefficients between measurements and modeling were 0.63 and 0.77 for the total HF-EMF strengths and for all mobile phone frequency bands. First evaluation of our geospatial model yielded substantial agreement between modeling and measurements. However, before the model can be applied for future epidemiologic research, additional validation studies focusing on indoor values are needed to improve model validity.
Most QST measurements have acceptable reliability in patients with chronic low back pain.
Although prevalent in chronic pain, generalized central hypersensitivity is not present in every patient. An individual assessment is therefore required in order to detect altered pain processing. The broad basic knowledge about central hypersensitivity now needs to be translated into concrete clinical consequences, so that patients can be offered an individually tailored mechanism-based treatment.
Using differential display, we isolated DDC-4, a secreted frizzled-related protein (sFRP), which is induced in the physiological apoptosis of hormonally regulated, reproductive tissues such as mammary gland, prostate, corpus luteum and uterus. The role of this gene in apoptosis was studied in animals overexpressing ectopic DDC-4/sFRP-4. Transgenic mice bearing the DDC-4/sFRP-4 cDNA under the control of the MMTV-LTR promoter showed lactational insufficiency and many apoptotic cells in the alveoli between day 19 of pregnancy and day 4 of lactation as demonstrated by TUNEL reaction and the presence of activated caspase-3. We performed a PKB/Akt kinase assay and studied several of its substrates using phosphorylation-specific antibodies to show reduced phosphorylation in PKB/Akt itself, as well as in glycogen synthetase kinase-3b (GSK-3b), BAD, and Forkhead. Taken together, our results show a role for DDC-4/sFRP-4 in abrogating an epithelial cell survival pathway at the onset of mammary gland involution.
Diffuse noxious inhibitory control (DNIC) is described as one possible mechanism of acupuncture analgesia. This study investigated the analgesic effect of acupuncture without stimulation compared to nonpenetrating sham acupuncture (NPSA) and cold-pressor-induced DNIC. Forty-five subjects received each of the three interventions in a randomized order. The analgesic effect was measured using pressure algometry at the second toe before and after each of the interventions. Pressure pain detection threshold (PPDT) rose from 299 kPa (SD 112 kPa) to 364 kPa (SD 144), 353 kPa (SD 135), and 467 kPa (SD 168) after acupuncture, NPSA, and DNIC test, respectively. There was no statistically significant difference between acupuncture and NPSA at any time, but a significantly higher increase of PPDT in the DNIC test compared to acupuncture and NPSA. PPDT decreased after the DNIC test, whereas it remained stable after acupuncture and NPSA. Acupuncture needling at low pain stimulus intensity showed a small analgesic effect which did not significantly differ from placebo response and was significantly less than a DNIC-like effect of a painful noninvasive stimulus.
SummaryThe aim of this prospective clinical study was to evaluate the location of paravertebral catheters that were placed using the classical landmark puncture technique and to correlate the distribution of contrast dye injected through the catheters with the extent of somatic block. Paravertebral catheter placement was attempted in 31 patients after video-assisted thoracic surgery. In one patient, an ultrasound-guided approach was chosen after failed catheter placement using the landmark method. A fluoroscopic examination in two planes using contrast dye was followed by injection of local anaesthetic and subsequent clinical testing of the extent of the anaesthetised area. In nine patients (29%), spread of contrast dye was not seen within the paravertebral space as intended. Misplaced catheters were in the epidural space (three patients), in the erector spinae musculature (five patients), and in the pleural space (one patient). There was also a discrepancy between the radiological findings and the observed distribution of loss of sensation. We have demonstrated an unacceptably high misplacement rate of paravertebral catheters using the landmark method. Additional research is required to compare the efficacy and safety of continuous paravertebral block using ultrasound-guided techniques or surgical inserted catheters.
Background: Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasoundguided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Methods: Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement , and chance-independent agreement ⌽ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. Results: One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), was 0.74 (0.64-0.83), and ⌽ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Conclusions: Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.