A reduction of the inner diameter of the hollow fibers in high-flux dialyzers may result in a significant increase of the blood compartment resistance. In turn, this results in increased rates of internal filtration and backfiltration. The practical effect in clinical dialysis is demonstrated on middle molecules. While, in fact, the clearances for small solutes such as urea and creatinine are not affected, the clearances of larger solutes such as vitamin B12 or inulin increase significantly (P < 0.01).
Ultrafiltration and pressure profiles in hollow fiber dialyzers with different hydraulic permeabilities have been investigated with a new scintigraphic method. Radiolabelled albumin macroaggregates, used as a nondiffusible marker molecule, were added to the blood in an in vitro circuit and circulated through cuprophan and polysulphon dialyzers. Since the marker molecule was too big to cross the dialysis membrane, its changes in concentration were assumed to occur in response to the variation of the blood water content (filtration or back-filtration). These changes in concentration, recorded by a gamma camera, were evaluated to establish the cumulative values of filtration and back-filtration and their relevant profiles along the length of the dialyzer. The achieved data were compared with the experimental values of ultrafiltration empirically measured and with the theoretical values predicted by a classic linear method. Two conditions were analyzed: A) the minimal filtration rate necessary to avoid back-filtration (critical filtration); and B) the condition of zero net filtration in which filtration equals back-filtration. The nuclear method proved to be extremely precise in predicting the ultrafiltration values and significantly more precise than the linear method, especially for the highly permeable dialyzer. The reason for that probably depends on the non-linear pressure and ultrafiltration profile observed with the scintigraphic pattern of the dialyzer. Viscosity changes and local variations in blood flow may in fact interfere with the pressure drop inside the hollow fibers and result in such a complex behavior. The other interesting aspect of this method is the possibility of accurate measurement of the amount of back-filtration that wouldn't be possible with simple calculations. In conclusion, the complex nature of the phenomena regulating the water fluxes in hollow fiber dialyzers requires more complex calculation than a simple linear model to achieve an accurate range of predictability.
In lung cancer, triggering procedures increase the signal to noise ratio. The increase in SUV determined by gating is very variable, but generally relevant. This could lead to an SUV values cut-off revision, and may have an impact on smaller lesions detection.
Background: Inadequate removal of molecules between 5 and 50 KDa may cause long-term complication in chronic hemodialysis. Medium cut-off (MCO) is a new class of membranes with enhanced sieving properties and negligible albumin loss. MCO membrane makes it possible to perform expanded hemodialysis (HDx), a technique based on high internal filtration (IF).The present study is designed to quantify IF in 2 MCO dialyzers (Theranova 400 and 500, Baxter, Deerfield, USA) using a nuclear imaging technique previously validated. Methods: Blood and dialysate compartment pressure drop along with transmembrane pressure; they were measured in a closed in vitro circuit with human blood (blood flow [QB] = 300 and 400 mL/min; dialysate flow 500 mL/min; net ultrafiltration rate 0 mL/min). A non-diffusible marker molecule (albumin macro-aggregates labeled with 99Tc metastable) was injected in the blood compartment and nuclear emission was recorded by a gamma camera. Relative variations in the concentration of the marker molecule along the length of the filter were used to calculate local cross filtration. Results: Based on marker concentration profiles, IF was estimated. For Theranova 400, IF were 29.7 and 41.6 mL/min for QB of 300 and 400 mL/min. For Theranova 500, IF were 31.6 and 53.1 mL/min for QB of 300 and 400 mL/min respectively. Conclusions: MCO membrane provides significant amounts of IF due to the particular combination between hydraulic permeability of the membrane and reduced inner diameter of the fibers. High IF combined with enhanced sieving profile of MCO membrane leads to improved removal of a wider spectrum of uremia retention molecules in HDx, without requiring complex equipment.
This approach suggests that changes in design of the dialyzer may affect its performance. The use of internal filtration is suggested to improve convection and dialyzer efficiency for larger solutes without the requirement for high volumes of replacement fluid, as is the case for current hemodiafiltration techniques.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.