Pressurized distensible tubes are subject to aneurysms. Aneurysm inception will take place at a location along the tube when a critical pressure, relative to tube wall thickness at that location, is reached. Parents will recognise the existence of critical pressure when endeavouring to inflate a party balloon. Another example of aneurysm is the thoracic aortic aneurysm corresponding to
The theoretical treatise of the companion paper produced three distinct approaches of increasing complexity. Just as the presented theory is equally applicable to other medical, scientific or engineering applications, so the systematic numerical investigation now reported is relevant to these fields of study. An independently developed finite element analysis (FEA) solution is used to show that the commercial package selected provides critical pressure predictions of a consistent order of magnitude. The FEA sensitivity analysis considers five distinct elements with up to seven alternative strain-energy functions and different combinations of uniaxial, equi-biaxial and pure shear data sets to identify the effect on critical pressure prediction and overall behaviour of a pressurised distensible tube. This represents the most comprehensive comparative study available in the open literature. For a selected strain-energy function the impact of the variation of length to initial radius and wall thickness to initial radius are investigated. Thereafter it is demonstrated that these two ratios rather than actual dimensions are the driving factors behind pressurised tube behaviour.
A new anisotropic viscoelastic model is developed for application to the aortic valve (AV). The directional dependency in the mechanical properties of the valve, arising from the predominantly circumferential alignment of collagen fibres, is accounted for in the form of transverse isotropy. The rate dependency of the valve's mechanical behaviour is considered to stem from the viscous (η) dissipative effects of the AV matrix, and is incorporated as an explicit function of the deformation rate (trueλ˙). Model (material) parameters were determined from uniaxial tensile deformation tests of porcine AV specimens at various deformation rates, by fitting the model to each experimental dataset. It is shown that the model provides an excellent fit to the experimental data across all different rates and satisfies the condition of strict local convexity. Based on the fitting results, a nonlinear relationship between η and trueλ˙ is established, highlighting a ‘shear-thinning’ behaviour for the AV with increase in the deformation rate. Using the model and these outcomes, the stress–deformation curves of the AV tissue under physiological deformation rates in both the circumferential and radial directions are predicted and presented. To verify the predictive capabilities of the model, the stress–deformation curves of AV specimens at an intermediate deformation rate were estimated and validated against the experimental data at that rate, showing an excellent agreement. While the model is primarily developed for application to the AV, it may be applied without the loss of generality to other collagenous soft tissues possessing a similar structure, with a single preferred direction of embedded collagen fibres.
This paper is concerned with proposing a suitable structurally motivated strain energy function, denoted by Weelastin network, for modeling the deformation of the elastin network within the aortic valve (AV) tissue. The AV elastin network is the main noncollagenous load-bearing component of the valve matrix, and therefore, in the context of continuum-based modeling of the AV, the Weelastin network strain energy function would essentially serve to model the contribution of the "isotropic matrix." To date, such a function has mainly been considered as either a generic neo-Hookean term or a general exponential function. In this paper, we take advantage of the established structural analogy between the network of elastin chains and the freely jointed molecular chain networks to customize a structurally motivated Weelastin network function on this basis. The ensuing stress-strain (force-stretch) relationships are thus derived and fitted to the experimental data points reported by (Vesely, 1998, "The Role of Elastin in Aortic Valve Mechanics," J. Biomech., 31, pp. 115-123) for intact AV elastin network specimens under uniaxial tension. The fitting results are then compared with those of the neo-Hookean and the general exponential models, as the frequently used models in the literature, as well as the "Arruda-Boyce" model as the gold standard of the network chain models. It is shown that our proposed Weelastin network function, together with the general exponential and the Arruda-Boyce models provide excellent fits to the data, with R2 values in excess of 0.98, while the neo-Hookean function is entirely inadequate for modeling the AV elastin network. However, the general exponential function may not be amenable to rigorous interpretation, as there is no structural meaning attached to the model. It is also shown that the parameters estimated by the Arruda-Boyce model are not mathematically and structurally valid, despite providing very good fits. We thus conclude that our proposed strain energy function Weelastin network is the preferred choice for modeling the behavior of the AV elastin network and thereby the isotropic matrix. This function may therefore be superimposed onto that of the anisotropic collagen fibers family in order to develop a structurally motivated continuum-based model for the AV.
The application of a newly proposed generalised neo-Hookean strain energy function to the inflation of incompressible rubber-like spherical and cylindrical shells is demonstrated in this paper. The pressure ($P$ P ) – inflation ($\lambda $ λ or $v$ v ) relationships are derived and presented for four shells: thin- and thick-walled spherical balloons, and thin- and thick-walled cylindrical tubes. Characteristics of the inflation curves predicted by the model for the four considered shells are analysed and the critical values of the model parameters for exhibiting the limit-point instability are established. The application of the model to extant experimental datasets procured from studies across 19th to 21st century will be demonstrated, showing favourable agreement between the model and the experimental data. The capability of the model to capture the two characteristic instability phenomena in the inflation of rubber-like materials, namely the limit-point and inflation-jump instabilities, will be made evident from both the theoretical analysis and curve-fitting approaches presented in this study. A comparison with the predictions of the Gent model for the considered data is also demonstrated and is shown that our presented model provides improved fits. Given the simplicity of the model, its ability to fit a wide range of experimental data and capture both limit-point and inflation-jump instabilities, we propose the application of our model to the inflation of rubber-like materials.
Nanoparticulate technologies have revolutionized drug delivery allowing for passive and active targeting, altered biodistribution, controlled drug release (temporospatial or triggered), enhanced stability, improved solubilization capacity, and a reduction in dose and adverse effects. However, their manufacture remains immature, and challenges exist on an industrial scale due to high batch-to-batch variability hindering their clinical translation. Lipid-based nanomedicines remain the most widely approved nanomedicines, and their current manufacturing methods remain discontinuous and face several problems such as high batch-to-batch variability affecting the critical quality attributes (CQAs) of the product, laborious multistep processes, need for an expert workforce, and not being easily amenable to industrial scale-up involving typically a complex process control. Several techniques have emerged in recent years for nanomedicine manufacture, but a paradigm shift occurred when microfluidic strategies able to mix fluids in channels with dimensions of tens of micrometers and small volumes of liquid reagents in a highly controlled manner to form nanoparticles with tunable and reproducible structure were employed. In this review, we summarize the recent advancements in the manufacturing of lipid-based nanomedicines using microfluidics with particular emphasis on the parameters that govern the control of CQAs of final nanomedicines. The impact of microfluidic environments on formation dynamics of nanomaterials, and the application of microdevices as platforms for nanomaterial screening are also discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.