Nowadays, the use of implanted devices is a well-acknowledged practice in the field of orthopaedic and dental surgery. Scientific research and clinical experience suggest that the successful exploitation of these devices mainly depends on osseointegration, considered as both anatomical congruency and load-bearing capacity. Indeed, the osseointegration process is influenced by a wide range of factors: anatomical location, implant size and design, surgical procedure, loading effects, biological fluids, age and sex, and, in particular, surface characteristics. For this reason, several attempts have been aimed at modifying implant surface composition and morphology to optimise implant-to-bone contact and improve integration. Preliminary interactions between implanted materials and biological environment are deemed to be governed by the surface properties; they control the amount and quality of cell adhesion on the surface and, consequently, cell/tissue growth. Thus, surface properties govern new bone tissue formation and implant osseointegration. This paper reviews the state of art in the field of physical, chemical and biochemical treatments commonly used on Ti-based biomaterials for the production of biomedical devices. In particular, roughness characteristics due to physical and chemical techniques are investigated; the development of biologically active surfaces by means of biochemical functionalisation is also considered.
Xenogeneic pericardium-based substitutes are employed for several surgical indications after chemical shielding, limiting their biocompatibility and therapeutic durability. Adverse responses to these replacements might be prevented by tissue decellularization, ideally removing cells and preserving the original extracellular matrix (ECM). The aim of this study was to compare the mostly applied pericardia in clinics, i.e., bovine and porcine tissues, after their decellularization, and obtain new insights for their possible surgical use. Bovine and porcine pericardia were submitted to TRICOL decellularization, based on osmotic shock, detergents and nuclease treatment. TRICOL procedure resulted in being effective in cell removal and preservation of ECM architecture of both species’ scaffolds. Collagen and elastin were retained but glycosaminoglycans were reduced, significantly for bovine scaffolds. Tissue hydration was varied by decellularization, with a rise for bovine pericardia and a decrease for porcine ones. TRICOL significantly increased porcine pericardial thickness, while a non-significant reduction was observed for the bovine counterpart. The protein secondary structure and thermal denaturation profile of both species’ scaffolds were unaltered. Both pericardial tissues showed augmented biomechanical compliance after decellularization. The ECM bioactivity of bovine and porcine pericardia was unaffected by decellularization, sustaining viability and proliferation of human mesenchymal stem cells and endothelial cells. In conclusion, decellularized bovine and porcine pericardia demonstrate possessing the characteristics that are suitable for the creation of novel scaffolds for reconstruction or replacement: differences in water content, thickness and glycosaminoglycans might influence some of their biomechanical properties and, hence, their indication for surgical use.
Mammalian pericardia are currently used for the production of percutaneous prosthetic heart valves. The characteristics of biological tissues largely influence the durability of prosthetic devices used in the percutaneous approach and in traditional surgery, too. This paper reviews methodologies employed to assess and compare mechanical properties of pericardial patches from different mammalian species in order to identify the biomaterials adequate for manufacturing prosthetic heart valves.
The development of viable and functional tissue-engineered heart valves (TEHVs) is a challenge that, for almost two decades, the scientific community has been committed to face to create life-lasting prosthetic devices for treating heart valve diseases. One of the main drawbacks of tissue-based commercial substitutes, xenografts and homografts, is their lack of viability, and hence failure to grow, repair, and remodel. In adults, the average bioprostheses life span is around 13 years, followed by structural valve degeneration, such as calcification; in pediatric, mechanical valves are commonly used instead of biological substitutes, as in young patients, the mobilization of calcium, due to bone remodeling, accelerates the calcification process. Moreover, neither mechanical nor bioprostheses are able to follow children's body growth. Cell seeding and repopulation of acellular heart valve scaffolds, biological and polymeric, appears as a promising way to create a living valve. Biomechanical stimuli have significant impact on cell behavior including in vitro differentiation, and physiological hemodynamic conditioning has been found to promote new tissue development. These concepts have led scientists to design bioreactors to mimic the in vivo environment of heart valves. Many different types of somatic and stem cells have been tested for colonizing both the surface and the core of the valve matrix but controversial results have been achieved so far.
A fundamental goal in the field of implantology is the design of innovative devices suitable for promoting implant-to-tissue integration. This result can be achieved by means of surface modifications aimed at optimizing tissue regeneration. In the framework of oral and orthopedic implantology, surface modifications concern both the optimization of titanium/titanium alloy surface roughness and the attachment of biochemical factors able to guide cellular adhesion and/or growth. This article focuses on the covalent attachment of two different adhesive peptides to rough titanium disks. The capability of biomimetic surfaces to increase osteoblast adhesion and the specificity of their biological activity due to the presence of cell adhesion signal-motif have also been investigated. In addition, surface analyses by profilometry, X-ray photoelectron spectroscopy, and time of flight-secondary ion mass spectrometry have been carried out to investigate the effects and modifications induced by grafting procedures.
Bladder cancer (BC) is among the most common malignancies in the world and a relevant cause of cancer mortality. BC is one of the most frequent causes for bladder removal through radical cystectomy, the gold-standard treatment for localized muscle-invasive and some cases of high-risk, non-muscle-invasive bladder cancer. In order to restore urinary functionality, an autologous intestinal segment has to be used to create a urinary diversion. However, several complications are associated with bowel-tract removal, affecting patients’ quality of life. The present study project aims to develop a bio-engineered material to simplify this surgical procedure, avoiding related surgical complications and improving patients’ quality of life. The main novelty of such a therapeutic approach is the decellularization of a porcine small intestinal submucosa (SIS) conduit to replace the autologous intestinal segment currently used as urinary diversion after radical cystectomy, while avoiding an immune rejection. Here, we performed a preliminary evaluation of this acellular product by developing a novel decellularization process based on an environmentally friendly, mild detergent, i.e., Tergitol, to replace the recently declared toxic Triton X-100. Treatment efficacy was evaluated through histology, DNA, hydroxyproline and elastin quantification, mechanical and insufflation tests, two-photon microscopy, FTIR analysis, and cytocompatibility tests. The optimized decellularization protocol is effective in removing cells, including DNA content, from the porcine SIS, while preserving the integrity of the extracellular matrix despite an increase in stiffness. An effective sterilization protocol was found, and cytocompatibility of treated SIS was demonstrated from day 1 to day 7, during which human fibroblasts were able to increase in number and strongly organize along tissue fibres. Taken together, this in vitro study suggests that SIS is a suitable candidate for use in urinary diversions in place of autologous intestinal segments, considering the optimal results of decellularization and cell proliferation. Further efforts should be undertaken in order to improve SIS conduit patency and impermeability to realize a future viable substitute.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.