By combining quartz crystal microbalance with dissipation monitoring (QCM-D) and surface plasmon resonance (SPR), the organic mass, water content, and corresponding protein film structure of fibrinogen adsorbed to acrylic polymeric substrates with varying polymer chain flexibility was investigated. Albumin and immunoglobulin G were included as reference proteins. For fibrinogen, the QCM-D model resulted in decreased adsorbed mass with increased polymer chain flexibility. This stands in contrast to the SPR model, in which the adsorbed mass increased with increased polymer chain flexibility. As the QCM-D model includes the hydrodynamically coupled water, we propose that on the nonflexible polymer significant protein conformational change with water incorporation in the protein film takes place. Fibrinogen maintained a more native conformation on the flexible polymer, probably due to polymer chain rearrangement rather than protein conformational change. In comparison with immunoglobulin G and albumin, polymer chain flexibility had only minor impact on adsorbed mass and protein structure. Understanding the adsorption and corresponding conformational change of a protein together with the mutual rearrangement of the polymer chain upon adsorption not only has implications in biomaterial science but could also increase the efficacy of molecular imprinted polymers (MIPs).
In this study we analyzed the blood compatibility of bacterial cellulose (BC) as a new biosynthetic material for use as a vascular graft. As reference materials we used expanded polytetrafluoroethylene (ePTFE) and poly(ethylene terephthalate) (PET) vascular grafts. These materials are in clinical use today. Tubes with inner diameters of both 4 (not PET) and 6 mm were tested. Heparin-coated PVC tubes (hepPVC) were used as a negative control. Platelet consumption and thrombin-antithrombin complex (TAT) were used as parameters of coagulation and for complement activation, sC3a and sC5b-9 were used. The investigated parameters were measured after 1-h exposure to freshly drawn human blood supplemented with a low dose of heparin in a Chandler loop system. The results showed that BC exhibits no significant difference in platelet consumption, as compared with PET (6 mm), ePTFE and hepPVC. The PET material consumed more platelets than any of the other materials. The TAT generation for 4 mm tubes was not significantly different between BC and the other materials. For 6 mm tubes, however, differences were observed between hepPVC and PET (p < 0.0001); BC and hepPVC (p = 0.0016); ePTFE and PET (p < 0.0001); BC and ePTFE (p = 0.0029); BC and PET (p = 0.0141). Surprisingly, considering the low platelet consumption, the complement activation parameters (sC3a and sC5b-9) were much higher for BC, as compared with the other materials for both 4 and 6 mm tubes.
Bacterial cellulose (BC) is a polysaccharide produced by Acetobacter Xylinum bacteria with interesting properties for arterial grafting and vascular tissue engineering including high-burst pressure, high-water content, high crystallinity, and an ultrafine highly pure fibrous structure similar to that of collagen. Given that compliance mismatch is one of the main factors contributing to the development of intimal hyperplasia in vascular replacement conduits, an in depth investigation of support mechanical properties of BC is required to further supporting its use in cardiovascular-grafting applications. The aim of this study was to mechanically characterize BC and also study its potential to accommodate vascular cells. To achieve these aims, inflation tests and uniaxial tensile tests were carried out on BC samples. In addition, dynamic compliance tests were conducted on BC tubes, and the results were compared to that of arteries, saphenous vein, expanded polytetrafluoroethylene, and Dacron grafts. BC tubes exhibited a compliance response similar to human saphenous vein with a mean compliance value of 4.27 × 10(-2) % per millimeter of mercury over the pressure range of 30-120 mmHg. In addition, bovine smooth muscle cells and endothelial cells were cultured on BC samples, and histology and fluorescent imaging analysis were carried out showing good adherence and biocompatibility. Finally, a method to predict the mechanical behavior of BC grafts in situ was established, whereby a constitutive model for BC was determined and used to model the BC tubes under inflation using finite element analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.