The unification of the theory of relativity and quantum mechanics is a long-standing challenge in contemporary physics. Experimental techniques in quantum optics have only recently reached the maturity required for the investigation of quantum systems under the influence of non-inertial motion, such as being held at rest in gravitational fields, or subjected to uniform accelerations. Here, we report on experiments in which a genuine quantum state of an entangled photon pair is exposed to a series of different accelerations. We measure an entanglement witness for g-values ranging from 30 mg to up to 30 g—under free-fall as well on a spinning centrifuge—and have thus derived an upper bound on the effects of uniform acceleration on photonic entanglement.
This paper focuses on exploring ways to improve the performance of LiDAR imagers through fog. One of the known weaknesses of LiDAR technology is the lack of tolerance to adverse environmental conditions, such as the presence of fog, which hampers the future development of LiDAR in several markets. Within this paper, a LiDAR unit is designed and constructed to be able to apply temporal and polarimetric discrimination for detecting the number of signal photons received with detailed control of its temporal and spatial distribution under co-polarized and cross-polarized configurations. The system is evaluated using different experiments in a macro-scale fog chamber under controlled fog conditions. Using the complete digitization of the acquired signals, we analyze the natural light media response, to see that due to its characteristics it could be directly filtered out. Moreover, we confirm that there exists a polarization memory effect, which, by using a polarimetric cross-configuration detector, allows improvement of object detection in point clouds. These results are useful for applications related to computer vision, in fields like autonomous vehicles or outdoor surveillance where many variable types of environmental conditions may be present.
Whole eye visualization and morphometry are of high relevance in clinical practice. However, most standard ophthalmic OCT instruments are dedicated either to retinal or to anterior segment imaging. We demonstrate a swept source optical coherence tomography system (SS-OCT) that images both the whole anterior segment and the retina alternately using a single source and detector. A pilot population was imaged with the proof of concept prototype. We demonstrate the clinical potential of whole eye OCT screening for the description and early detection of relevant clinical features in the anterior segment and retina of several patients.
In recent times, there has been a surge of interest in LiDAR imaging systems, particularly in outdoor terrestrial applications associated with computer vision. However, a significant hurdle preventing their widespread implementation lies in their limited tolerance for adverse weather conditions, such as fog. To address this challenge, researchers have explored the capability of polarization in improving detection capabilities in such media. This paper explores the potential of LiDAR technology to obtain polarized images through fog and investigates the impact of fog on object detection using digitized temporal signals and point clouds. The study utilizes a LiDAR-polarized imaging system using circular polarization, which has been shown to enhance image contrast in highly-dispersive media. The analysis of the polarimetric information of the backscattered light signal in fog reveals its influence on object detection and evaluates the range difference between orthogonal polarimetric channels: coplanar and cross-configuration. The results demonstrate that cross-configuration detection provides larger range and more detailed point clouds compared to coplanar configuration, particularly benefiting metallic objects, for the same foggy conditions. By utilizing circularly polarized incident light and cross-configuration detection, the LiDAR system can improve the signal-to-noise ratio by filtering out the co-polarized fog responses. However, the range of the system may be reduced compared to nonpolarized detection. Overall, our findings indicate that utilizing a cross-polarization detection setup can effectively reduce the impact of fog backscatter while preserving the return signal from objects of interest in the majority of cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.