The present results show that older adults who are self-reported as non-white, with one or more teeth in the oral cavity and with poor/very poor self-assessed oral health have lower SOC scores.
The use of mandibular overdentures (MO) for the rehabilitation of totally edentulous individuals with limited bone availability is widespread and has proven clinical success. Narrow diameter implants (NDI) are available on the market as MO retainers to solve problems related to limited bone availability and bone thickness, providing a low-cost, minimally invasive treatment option. This technique evolved over the years, and changes frequently involved the number of implants used as MO retainers, as the adoption of a smaller number of implants can generate biomechanical disadvantages, contributing to the increased stress in peri-implant tissues, which may accelerate marginal bone loss (MBL), in addition to reducing masticatory capacity and satisfaction with rehabilitation. Some studies pointed out that the use of 3 or more implants as MO retainers improves the biomechanics. Thus, the objective of this study was to report 3 different clinical cases where 3 or more NDI were adopted to retain mandibular overdentures in association with diverse loading protocols: (i) 3 implants adopting conventional loading, (ii) 4 implants using progressive loading, and (iii) 4 implants with hybrid loading. The case with 4 implants and progressive loading showed a slight worsening of masticatory function at 1 year, in addition to a more pronounced MBL compared to other cases, but with improvements in satisfaction and oral health-related quality of life. Thus, NDI can be used as MO retainers with predictability and clinical success, using different numbers of implants and loading protocols.
Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.5–1.0 μm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 μm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques.
Background: Facial types may interfere in the oral health-related quality of life (OHRQoL) and masticatory performance of implant-retained mandibular overdenture (IMO) wearers.Purpose: Investigate the medium-term changes in the masticatory function (MF) and OHRQoL parameters of IMO users, as a function of facial pattern, anteroposterior skeletal discrepancy, and sex.Methods: Forty IMO users, most of them Caucasian (90%) with average age of 69.17 years were classified according to their facial pattern and antero-posterior discrepancy prior to rehabilitation. MF was evaluated by the multiple sieves method to determine the average particle size (X50), heterogeneity (B) and masticatory efficiency (ME, calculated as the percentage of material retained in the 5.6 and 2.8 mm sieves), using Masticatory performance (MP) and swallowing threshold (ST) tests. OHRQoL was measured by applying the dental impact on daily life (DIDL) questionnaire. The data were analyzed by Wilcoxon-paired tests to analyze changes in MF parameters over time, and mixed-effect multilevel regression models were employed to verify differences between groups.Results: Significant changes were still observed in the 3rd year for the ST test with improvements in B for Mesofacial and in time for Dolichofacial individuals, while ME_2.8 deteriorated for Brachyfacial participants. B values of Class I and male individuals improved and brachyfacial individuals still presented worse homogenization (B) than Mesofacial participants in both masticatory tests. Class II and III participants still showed improvements in ME_5.6 and time compared to Class I despite increases in X50. Class II individuals needed less cycles than Class I in the 3rd year. Brachyfacial participants scored lower in the Appearance domain than Mesofacial ones in the 3rd year. Dolichofacial participants and Class III patients scored lower in the Oral Comfort domain than Mesofacial and Class I, respectively. In addition, age influenced the Pain, Oral Comfort and General Performance domains in the 3rd year.Conclusions: Differences in facial morphology continue to influence the MF and OHRQoL outcomes in the 3rd year, and age influenced some OHRQoL domains. Brachyfacial individuals continue to benefit least from rehabilitation with IMO according to masticatory parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.