Background:Electronic cigarettes (e-cigarettes) generate an aerosol by heating a solution (e-liquid) with a metallic coil. Whether metals are transferred from the coil to the aerosol is unknown.Objective:Our goal was to investigate the transfer of metals from the heating coil to the e-liquid in the e-cigarette tank and the generated aerosol.Methods:We sampled 56 e-cigarette devices from daily e-cigarette users and obtained samples from the refilling dispenser, aerosol, and remaining e-liquid in the tank. Aerosol liquid was collected via deposition of aerosol droplets in a series of conical pipette tips. Metals were reported as mass fractions (μg/kg) in liquids and converted to mass concentrations (mg/m3) for aerosols.Results:Median metal concentrations (μg/kg) were higher in samples from the aerosol and tank vs. the dispenser (all p<0.001): 16.3 and 31.2 vs. 10.9 for Al; 8.38 and 55.4 vs. <0.5 for Cr; 68.4 and 233 vs. 2.03 for Ni; 14.8 and 40.2 vs. 0.476 for Pb; and 515 and 426 vs. 13.1 for Zn. Mn, Fe, Cu, Sb, and Sn were detectable in most samples. Cd was detected in 0.0, 30.4, and 55.1% of the dispenser, aerosol, and tank samples respectively. Arsenic was detected in 10.7% of dispenser samples (median 26.7μg/kg) and these concentrations were similar in aerosol and tank samples. Aerosol mass concentrations (mg/m3) for the detected metals spanned several orders of magnitude and exceeded current health-based limits in close to 50% or more of the samples for Cr, Mn, Ni, and Pb.Conclusions:Our findings indicate that e-cigarettes are a potential source of exposure to toxic metals (Cr, Ni, and Pb), and to metals that are toxic when inhaled (Mn and Zn). Markedly higher concentrations in the aerosol and tank samples versus the dispenser demonstrate that coil contact induced e-liquid contamination. https://doi.org/10.1289/EHP2175
Background and Aims The popularity of electronic cigarette devices is growing worldwide. The health impact of e-cigarette use, however, remains unclear. E-cigarettes are marketed as a safer alternative to cigarettes. The aim of this research was the characterization and quantification of toxic metal concentrations in five, nationally popular brands of cig-a-like e-cigarettes. Methods We analyzed the cartomizer liquid in 10 cartomizer refills for each of five brands by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results All of the tested metals (cadmium, chromium, lead, manganese and nickel) were found in the e-liquids analyzed. Across all analyzed brands, mean (SD) concentrations ranged from 3.20 (0.454) to 1960 (1540) μg/L for lead, 53.9 (6.95) to 2110 (5220) μg/L for chromium and 115 (49.4) to 22600 (24400) μg/L for nickel. Manganese concentrations ranged from 28.7 (9.79) to 6919 (12200) μg/L. We found marked variability in nickel and chromium concentration within and between brands, which may come from nichrome heating elements. Conclusion Additional research is needed to evaluate whether e-cigarettes represent a relevant exposure pathway for toxic metals in users.
We have increased organic field-effect transistor (OFET) NH3 response using tris-(pentafluorophenyl)borane (TPFB) as receptor. OFETs with this additive detect concentrations of 450 ppb v/v, with a limit of detection of 350 ppb, the highest sensitivity yet from semiconductor films; in comparison, when triphenylmethane (TPM) and triphenylborane (TFB) were used as an additive, no obvious improvement of sensitivity was observed. These OFETs also show considerable selectivity with respect to common organic vapors, and stability to storage. Furthermore, excellent memory of exposure was achieved by keeping the exposed devices in a sealed container stored at −30°C, the first such capability demonstrated with OFETs.
The use of nontherapeutic levels of antibiotics in swine production can select for antibiotic resistance in commensal and pathogenic bacteria in swine. As a result, retail pork products, as well as surface and groundwaters contaminated with swine waste, have been shown to be sources of human exposure to antibiotic-resistant bacteria. However, it is unclear whether the air within swine operations also serves as a source of exposure to antibiotic-resistant bacterial pathogens. To investigate this issue, we sampled the air within a concentrated swine feeding operation with an all-glass impinger. Samples were analyzed using a method for the isolation of Enterococcus. A total of 137 presumptive Enterococcus isolates were identified to species level using standard biochemical tests and analyzed for resistance to erythromycin, clindamycin, virginiamycin, tetracycline, and vancomycin using the agar dilution method. Thirty-four percent of the isolates were confirmed as Enterococcus, 32% were identified as coagulase-negative staphylococci, and 33% were identified as viridans group streptococci. Regardless of bacterial species, 98% of the isolates expressed high-level resistance to at least two antibiotics commonly used in swine production. None of the isolates were resistant to vancomycin, an antibiotic that has never been approved for use in livestock in the United States. In conclusion, high-level multidrug-resistant Enterococcus, coagulase-negative staphylococci, and viridans group streptococci were detected in the air of a concentrated swine feeding operation. These findings suggest that the inhalation of air from these facilities may serve as an exposure pathway for the transfer of multidrug-resistant bacterial pathogens from swine to humans.
Recently, there has been a significant increase in the use of noncombustible nicotine-containing products, including electronic cigarettes (e-cigarettes). Of increasing popularity are e-cigarettes that can deliver high doses of nicotine over short periods of time. These devices have led to a rise in nicotine addiction in adolescent users who were nonsmokers. Use of noncombustible nicotine products by pregnant mothers is also increasing and can expose the developing fetus to nicotine, a known teratogen. In addition, young children are frequently exposed to secondhand and thirdhand nicotine aerosols generated by e-cigarettes, with little understanding of the effects these exposures can have on health. With the advent of these new nicotine-delivery systems, many concerns have arisen regarding the short-and long-term health effects of nicotine on childhood health during all stages of development. Although health studies on nicotine exposure alone are limited, educating policy makers and health care providers on the potential health effects of noncombustible nicotine is needed because public acceptance of these products has become so widespread. Most studies evaluating the effects of nicotine on health have been undertaken in the context of smoke exposure. Nevertheless, in vitro and in vivo preclinical studies strongly indicate that nicotine exposure alone can adversely affect the nervous, respiratory, immune, and cardiovascular systems, particularly when exposure occurs during critical developmental periods. In this review, we have included both preclinical and clinical studies to identify age-related health effects of nicotine exposure alone, examining the mechanisms underlying these effects.
Background-Electronic cigarettes (E-cigarettes) generate aerosol containing metal contaminants. Our goals were to quantify aerosol metal concentrations and to compare the effects of power setting and device type (closed-system vs. open-system) on metal release.Methods-Aerosol samples were collected from two closed-system devices (a cigalike and pod) and two open-system devices (mods). Each open-system device was operated at three different power settings to examine the effect of device power on metal release. Concentrations of 14 metals in e-cigarette aerosol collected via droplet deposition were measured using inductively coupled plasma mass spectroscopy. Aerosol metal concentrations were reported as mass fractions (μg/kg) in the e-liquid.Results-For open-system device 1 (OD1), median arsenic (As), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), lead (Pb), antimony (Sb), tin (Sn), and zinc (Zn) concentrations increased 14, 54, 17, 30, 41, 96, 14, 81, 631, and 7-fold when the device power was increased from low (20 W) to intermediate (40 W) setting. When the power was further increased from intermediate (40 W) to high (80 W) setting, concentrations of As, Cr, Cu, Mn, Ni, and Sb did not change significantly. For open-system device 2 (OD2), Cr and Mn concentrations increased significantly when device power was increased from low (40 W) to intermediate (120 W) setting, and then decreased significantly when power was further increased from intermediate (120 W) to high (200 W) setting. Among the four devices, aerosol metal concentrations were higher for the
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.