Rapid diagnosis and treatment of infectious meningitis and encephalitis are critical to minimize morbidity and mortality. Comprehensive testing of cerebrospinal fluid (CSF) often includes Gram stain, culture, antigen detection, and molecular methods, paired with chemical and cellular analyses. These methods may lack sensitivity or specificity, can take several days, and require significant volume for complete analysis. The FilmArray Meningitis/Encephalitis (ME) Panel is a multiplexed in vitro diagnostic test for the simultaneous, rapid (ϳ1-h) detection of 14 pathogens directly from CSF specimens: Escherichia coli K1, Haemophilus influenzae, Listeria monocytogenes, Neisseria meningitidis, Streptococcus pneumoniae, Streptococcus agalactiae, cytomegalovirus, enterovirus, herpes simplex virus 1 and 2, human herpesvirus 6, human parechovirus, varicella-zoster virus, and Cryptococcus neoformans/Cryptococcus gattii. We describe a multicenter evaluation of 1,560 prospectively collected CSF specimens with performance compared to culture (bacterial analytes) and PCR (all other analytes). The FilmArray ME Panel demonstrated a sensitivity or positive percentage of agreement of 100% for 9 of 14 analytes. Enterovirus and human herpesvirus type 6 had agreements of 95.7% and 85.7%, and L. monocytogenes and N. meningitidis were not observed in the study. For S. agalactiae, there was a single false-positive and false-negative result each, for a sensitivity and specificity of 0 and 99.9%, respectively. The specificity or negative percentage of agreement was 99.2% or greater for all other analytes. The FilmArray ME Panel is a sensitive and specific test to aid in diagnosis of ME. With use of this comprehensive and rapid test, improved patient outcomes and antimicrobial stewardship are anticipated.
fThe appropriate treatment and control of infectious gastroenteritis depend on the ability to rapidly detect the wide range of etiologic agents associated with the disease. Clinical laboratories currently utilize an array of different methodologies to test for bacterial, parasitic, and viral causes of gastroenteritis, a strategy that suffers from poor sensitivity, potentially long turnaround times, and complicated ordering practices and workflows. Additionally, there are limited or no testing methods routinely available for most diarrheagenic Escherichia coli strains, astroviruses, and sapoviruses. This study assessed the performance of the FilmArray Gastrointestinal (GI) Panel for the simultaneous detection of 22 different enteric pathogens directly from stool specimens: Campylobacter spp., Clostridium difficile (toxin A/B), Plesiomonas shigelloides, Salmonella spp., Vibrio spp., Vibrio cholerae, Yersinia enterocolitica, enteroaggregative E. coli, enteropathogenic E. coli, enterotoxigenic E. coli, Shiga-like toxin-producing E. coli (stx 1 and stx 2 ) (including specific detection of E. coli O157), Shigella spp./enteroinvasive E. coli, Cryptosporidium spp., Cyclospora cayetanensis, Entamoeba histolytica, Giardia lamblia, adenovirus F 40/41, astrovirus, norovirus GI/GII, rotavirus A, and sapovirus. Prospectively collected stool specimens (n ؍ 1,556) were evaluated using the BioFire FilmArray GI Panel and tested with conventional stool culture and molecular methods for comparison. The FilmArray GI Panel sensitivity was 100% for 12/22 targets and >94.5% for an additional 7/22 targets. For the remaining three targets, sensitivity could not be calculated due to the low prevalences in this study. The FilmArray GI Panel specificity was >97.1% for all panel targets. The FilmArray GI Panel provides a comprehensive, rapid, and streamlined alternative to conventional methods for the etiologic diagnosis of infectious gastroenteritis in the laboratory setting. The potential advantages include improved performance parameters, a more extensive menu of pathogens, and a turnaround time of as short as 1 h. Infectious gastroenteritis (IGE) is a leading cause of global morbidity and mortality. It is estimated that IGE contributes to the death of 2,195 children each day (1). IGE also contributes to serious morbidities, such as malnutrition, stunting, and impaired cognitive function (2, 3). Diarrheal disease disproportionately affects developing nations, but IGE remains a significant problem in industrialized countries as well. For example, it is estimated that each year, approximately 178.8 million cases of gastrointestinal illness occur in the United States, resulting in 474,000 hospitalizations and 5,000 deaths (4). Although the etiologic agents responsible for about 80% of these illnesses are unidentified or otherwise unspecified (4), norovirus and Salmonella spp. are currently the most commonly identified pathogens associated with food-borne disease in the United States and account for 5.5 and 1.0 million cases each year, resp...
The ability to provide timely identification of the causative agents of lower respiratory tract infections can promote better patient outcomes and support antimicrobial stewardship efforts. Current diagnostic testing options include culture, molecular testing, and antigen detection. These methods may require collection of various specimens, involve extensive sample treatment, and can suffer from low sensitivity and long turnaround times. This study assessed the performance of the BioFire FilmArray Pneumonia Panel (PN panel) and Pneumonia Plus Panel (PNplus panel), an FDA-cleared sample-to-answer assay that enables the detection of viruses, atypical bacteria, bacteria, and antimicrobial resistance marker genes from lower respiratory tract specimens (sputum and bronchoalveolar lavage [BAL] fluid). Semiquantitative results are also provided for the bacterial targets. This paper describes selected analytical and clinical studies that were conducted to evaluate performance of the panel for regulatory clearance. Prospectively collected respiratory specimens (846 BAL and 836 sputum specimens) evaluated with the PN panel were also tested by quantitative reference culture and molecular methods for comparison. The PN panel showed a sensitivity of 100% for 15/22 etiologic targets using BAL specimens and for 10/24 using sputum specimens. All other targets had sensitivities of ≥75% or were unable to be calculated due to low prevalence in the study population. Specificity for all targets was ≥87.2%, with many false-positive results compared to culture that were confirmed by alternative molecular methods. Appropriate adoption of this test could provide actionable diagnostic information that is anticipated to impact patient care and antimicrobial stewardship decisions.
The FilmArray Respiratory Panel 2 (RP2) is a multiplex in vitro diagnostic test for the simultaneous and rapid (∼45-min) detection of 22 pathogens directly from nasopharyngeal swab (NPS) samples. It contains updated (and in some instances redesigned) assays that improve upon the FilmArray Respiratory Panel (RP; version 1.7), with a faster run time. The organisms identified are adenovirus, coronavirus 229E, coronavirus HKU1, coronavirus NL63, coronavirus OC43, human metapneumovirus, human rhinovirus/enterovirus, influenza virus A, influenza virus A H1, influenza virus A H1-2009, influenza virus A H3, influenza virus B, parainfluenza virus 1, parainfluenza virus 2, parainfluenza virus 3, parainfluenza virus 4, respiratory syncytial virus, Bordetella pertussis, Chlamydia pneumoniae, and Mycoplasma pneumoniae. Two new targets are included in the FilmArray RP2: Middle East respiratory syndrome coronavirus and Bordetella parapertussis. This study provides data from a multicenter evaluation of 1,612 prospectively collected NPS samples, with performance compared to that of the FilmArray RP or PCR and sequencing. The overall percent agreement between the FilmArray RP2 and the comparator testing was 99.2%. The RP2 demonstrated a positive percent agreement of 91.7% or greater for detection of all but three analytes: coronavirus OC43, B. parapertussis, and B. pertussis. The FilmArray RP2 also demonstrated a negative percent agreement of ≥93.8% for all analytes. Of note, the adenovirus assay detects all genotypes, with a demonstrated increase in sensitivity. The FilmArray RP2 represents a significant improvement over the FilmArray RP, with a substantially shorter run time that could aid in the diagnosis of respiratory infections in a variety of clinical scenarios.
Lower respiratory tract infections, including hospital-acquired and ventilator-associated pneumonia, are common in hospitalized patient populations. Standard methods frequently fail to identify the infectious etiology due to the polymicrobial nature of respiratory specimens and the necessity of ordering specific tests to identify viral agents. The potential severity of these infections combined with a failure to clearly identify the causative pathogen results in administration of empirical antibiotic agents based on clinical presentation and other risk factors. We examined the impact of the multiplexed, semiquantitative BioFire FilmArray Pneumonia panel (PN panel) test on laboratory reporting for 259 adult inpatients submitting bronchoalveolar lavage (BAL) specimens for laboratory analysis. The PN panel demonstrated a combined 96.2% positive percent agreement (PPA) and 98.1% negative percent agreement (NPA) for the qualitative identification of 15 bacterial targets compared to routine bacterial culture. Semiquantitative values reported by the PN panel were frequently higher than values reported by culture, resulting in semiquantitative agreement (within the same log10 value) of 43.6% between the PN panel and culture; however, all bacterial targets reported as >105 CFU/ml in culture were reported as ≥105 genomic copies/ml by the PN panel. Viral targets were identified by the PN panel in 17.7% of specimens tested, of which 39.1% were detected in conjunction with a bacterial target. A review of patient medical records, including clinically prescribed antibiotics, revealed the potential for antibiotic adjustment in 70.7% of patients based on the PN panel result, including discontinuation or de-escalation in 48.2% of patients, resulting in an average savings of 6.2 antibiotic days/patient.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.