IMPORTANCE This is the first large-scale randomized clinical trial evaluating the effectiveness and safety of overminus spectacle therapy for treatment of intermittent exotropia (IXT).OBJECTIVE To evaluate the effectiveness of overminus spectacles to improve distance IXT control. DESIGN, SETTING, AND PARTICIPANTSThis randomized clinical trial conducted at 56 clinical sites between January 2017 and January 2019 associated with the Pediatric Eye Disease Investigator Group enrolled 386 children aged 3 to 10 years with IXT, a mean distance control score of 2 or worse, and a refractive error between 1.00 and −6.00 diopters (D). Data analysis was performed from February to December 2020.INTERVENTIONS Participants were randomly assigned to overminus spectacle therapy (−2.50 D for 12 months, then −1.25 D for 3 months, followed by nonoverminus spectacles for 3 months) or to nonoverminus spectacle use. MAIN OUTCOMES AND MEASURESPrimary and secondary outcomes were the mean distance IXT control scores of participants examined after 12 months of treatment (primary outcome) and at 18 months (3 months after treatment ended) assessed by an examiner masked to treatment group. Change in refractive error from baseline to 12 months was compared between groups. Analyses were performed using the intention-to-treat population. RESULTSThe mean (SD) age of 196 participants randomized to overminus therapy and 190 participants randomized to nonoverminus treatment was 6.3 (2.1) years, and 226 (59%) were female. Mean distance control at 12 months was better in participants treated with overminus spectacles than with nonoverminus spectacles (1.8 vs 2.8 points; adjusted difference, −0.8; 95% CI, −1.0 to −0.5; P < .001). At 18 months, there was little or no difference in mean distance control between overminus and nonoverminus groups (2.4 vs 2.7 points; adjusted difference, −0.2; 95% CI, −0.5 to 0.04; P = .09). Myopic shift from baseline to 12 months was greater in the overminus than the nonoverminus group (−0.42 D vs −0.04 D; adjusted difference, −0.37 D; 95% CI, −0.49 to −0.26 D; P < .001), with 33 of 189 children (17%) in the overminus group vs 2 of 169 (1%) in the nonoverminus group having a shift higher than 1.00 D.CONCLUSIONS AND RELEVANCE Children 3 to 10 years of age had improved distance exotropia control when assessed wearing overminus spectacles after 12 months of overminus treatment; however, this treatment was associated with increased myopic shift. The beneficial effect of overminus lens therapy on distance exotropia control was not maintained after treatment was tapered off for 3 months and children were examined 3 months later.
IMPORTANCECataract is an important cause of visual impairment in children. Data from a large pediatric cataract surgery registry can provide real-world estimates of visual outcomes and the 5-year cumulative incidence of adverse events. OBJECTIVE To assess visual acuity (VA), incidence of complications and additional eye operations, and refractive error outcomes 5 years after pediatric lensectomy among children younger than 13 years. DESIGN, SETTING, AND PARTICIPANTSThis prospective cohort study used data from the Pediatric Eye Disease Investigator Group clinical research registry. From June 2012 to July 2015, 61 eye care practices in the US, Canada, and the UK enrolled children from birth to less than 13 years of age who had undergone lensectomy for any reason during the preceding 45 days. Data were collected from medical record reviews annually thereafter for 5 years until September 28, 2020. EXPOSURES Lensectomy with or without implantation of an intraocular lens (IOL).MAIN OUTCOMES AND MEASURES Best-corrected VA and refractive error were measured from 4 to 6 years after the initial lensectomy. Cox proportional hazards regression was used to assess the 5-year incidence of glaucoma or glaucoma suspect and additional eye operations. Factors were evaluated separately for unilateral and bilateral aphakia and pseudophakia.RESULTS A total of 994 children (1268 eyes) undergoing bilateral or unilateral lensectomy were included (504 [51%] male; median age, 3.6 years; range, 2 weeks to 12.9 years). Five years after the initial lensectomy, the median VA among 701 eyes with available VA data (55%) was 20/63 (range, 20/40 to 20/100) in 182 of 316 bilateral aphakic eyes (58%), 20/32 (range, 20/25 to 20/50) in 209 of 386 bilateral pseudophakic eyes (54%), 20/200 (range, 20/50 to 20/618) in 124 of 202 unilateral aphakic eyes (61%), and 20/65 (range, 20/32 to 20/230) in 186 of 364 unilateral pseudophakic eyes (51%). The 5-year cumulative incidence of glaucoma or glaucoma suspect was 46% (95% CI, 28%-59%) in participants with bilateral aphakia, 7% (95% CI, 1%-12%) in those with bilateral pseudophakia, 25% (95% CI, 15%-34%) in those with unilateral aphakia, and 17% (95% CI, 5%-28%) in those with unilateral pseudophakia. The most common additional eye surgery was clearing the visual axis, with a 5-year cumulative incidence of 13% (95% CI, 8%-17%) in participants with bilateral aphakia, 33% (95% CI, 26%-39%) in those with bilateral pseudophakia, 11% (95% CI, 6%-15%) in those with unilateral aphakia, and 34% (95% CI, 28%-39%) in those with unilateral pseudophakia. The median 5-year change in spherical equivalent refractive error was −8.38 D (IQR, −11.38 D to −2.75 D) among 89 bilateral aphakic eyes, −1.63 D (IQR, −3.13 D to −0.25 D) among 130 bilateral pseudophakic eyes, −10.75 D (IQR, −20.50 D to −4.50 D) among 43 unilateral aphakic eyes, and −1.94 D (IQR, −3.25 D to −0.69 D) among 112 unilateral pseudophakic eyes. CONCLUSIONS AND RELEVANCEIn this cohort study, development of glaucoma or glaucoma suspect was common in children 5 ye...
SIGNIFICANCEA rigorously designed and calibrated symptom questionnaire for childhood intermittent exotropia would be useful for clinical care and for research.PURPOSEThe aim of this study was to Rasch-calibrate and evaluate the previously developed Child Intermittent Exotropia Symptom Questionnaire using data gathered as part of a randomized clinical trial.METHODSThe questionnaire was administered to 386 children aged 3 to 10 years with intermittent exotropia who were enrolled in a randomized clinical trial comparing overminus with nonoverminus spectacles. Participants were followed at 6 and 12 months while on treatment and at 18 months off treatment. Factor analysis determined dimensionality, and Rasch analysis evaluated questionnaire performance. Logit values were converted to 0 (best) to 100 (worst). We evaluated differences in questionnaire scores between treatment groups and time points, and correlations with control scores.RESULTSThe Child Intermittent Exotropia Symptom Questionnaire was unidimensional. Rasch analysis indicated that there was no notable local dependence and no significant differential item functioning for sex or age. There was suboptimal targeting (mean logit, −1.62), and person separation was somewhat poor (0.95). There were no significant differences in the Child Intermittent Exotropia Symptom score between overminus spectacles and nonoverminus spectacles at 6, 12, and 18 months. Combining data from both treatment groups, there was significant improvement from baseline at all follow-up visits (e.g., mean change from baseline to 12 months, −6.6 points; 95% confidence interval, −8.6 to −4.6). Child Intermittent Exotropia Symptom scores were not correlated with distance or near control scores at 12 months.CONCLUSIONSThe seven-item Rasch-scored Child Intermittent Exotropia Symptom Questionnaire is limited by suboptimal performance. Future study is needed to determine whether it may be useful for clinical practice and for research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.