The Urinary Tract Dilation classification system is reliable for evaluation of postnatal hydronephrosis and is valid in predicting surgical intervention.
Introduction: The DrillCutTM morcellator is marketed for its fast and highly efficient removal of prostatic tissue and a higher level of patient safety. However, a paucity of publications has looked into its actual efficacy and safety. The aim of our study was to evaluate its ex vivo and in vivo efficiency and to compare its results with other devices presented in the literature. Patients and Methods: We conducted a prospective pilot study on patients who underwent holmium laser enucleation of the prostate (HoLEP) from 2017 to 2018 using the Top-Down technique. Enucleated adenomas were morcellated using the DrillCutTM morcellator. We collected both preoperative and operative data. Operative data included the enucleated adenoma weight and operative time. Various morcellator parameters were collected including morcellation time and efficiency. We recorded the encountered complications and device malfunction. Ex vivo characteristics were evaluated in terms of morcellation speed and aspiration power. Results: Sixty consecutive patients with a median age of 72.8 years were included. The enucleated adenoma was retrieved in 12.5 min (4–58). The median resected prostatic weight was 90 g (44–242). The DrillCutTM efficiency was calculated as 6.46 g/min (2.7–15). Only one patient had a simple bladder mucosal injury. Device malfunction was encountered in 4 patients (6.6%) due to blockage of the morcellator blades. The ex vivo aspiration speed was 52 s/L, while the morcellation power was 14 g/2 min. Conclusion: Our results showed that the DrillCut morcellator was effective and safe in managing our patients post-HoLEP. The DrillCutTM has better ex vivo morcellation power but modest aspiration speed in comparison to other morcellators.
Introduction: Novel laser technologies have been developed for the minimally invasive surgical management of benign prostatic hyperplasia (BPH). The objective of this study was to assess the safety and efficacy of MOSESTM technology versus the thulium fiber laser (TFL) in patients with BPH undergoing transurethral enucleation of the prostate. Methods: We conducted a retrospective review of prospectively collected data of eighty-two patients who underwent transurethral enucleation of the prostate using MOSESTM or TFL technologies from August 2020 to September 2021. Preoperative and intraoperative parameters, in addition to postoperative outcomes, were collected and analyzed. Results: Twenty patients underwent transurethral enucleation of the prostate with TFL, while 62 had MOSESTM HoLEP. No statistically significant difference in preoperative characteristics was observed between the groups. Patients in the TFL group had longer median enucleation, hemostasis, and morcellation times (p < 0.001) than those in the MOSESTM cohort. The longer morcellation time of TFL is mostly related to less visibility. The postoperative outcomes IPSS, QoL, Qmax, and post void residual (PVR), were comparable between the groups at 1, 3 and 6 months. The incidence of urge urinary incontinence (p = 0.79), stress urinary incontinence (p = 0.97), and hospital readmission rates (p = 0.1) were comparable between the two groups. Conclusions: A satisfactory safety and efficacy profile with comparable postoperative outcomes was demonstrated for both techniques; though, MOSESTM technology was superior to TFL in terms of shorter overall operative time.
We report a case of 4 months old infant diagnosed as Klinefelter syndrome associated with perineal hypospadias, severe ventral chordee and complete penoscrotal transposition. A review of previous reported cases was carried out. Penoscrotal malformations at birth are very rare in Klinefelter syndrome. Awareness of the current standard indications of Karyotyping can help early detection of these cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.