Background: The prognosis of patients with untreated cardiac implantable electronic device (CIED) infection is poor. Whether removal of all leads by a successful transvenous lead extraction (TLE) procedure changes the prognosis is unclear.Objective: To identify predictors of mortality in patients with CIED infection despite successful TLE.Methods: Retrospective single-center analysis of prospectively collected database from consecutive patients undergoing TLE at our center. Predictors for mortality were identified and a score predicting high mortality rate was calculated.Results: A total of 371 consecutive patients underwent TLE, of whom 337 (90.8%) had complete hardware removal. Most were extracted due to infectious causes (81.3%).Approximately one-third (35%) died during a mean follow-up of 1056 ± 868 days. There was significantly higher mortality observed in the infectious group. Multivariate logistic regression models for infectious group only identified creatinine and albumin measurements as risk markers for 30 days mortality (odds ratio [OR], 1.68; 95% confidence interval [CI], 1.19-2.38; P = .003 and OR, 0.4; 95% CI, 0.16-0.97; P = .039, respectively).A risk score was created based on cutoff values of creatinine ≥2md/dL (1 point) and albumin ≤3.5 g/dL (1 point). A value of 2 points predicted a 50% chance of 30-day mortality and a 75% chance of 1-year mortality (P < .0001 for both).Conclusions: Creatinine and albumin can be used as a combined risk score to successfully identify patients at risk of death despite undergoing a successful TLE procedure for infectious reasons. This score could help decision making when contemplating on conservative antibiotic treatment vs TLE. K E Y W O R D S albumin, creatinine, infection, lead extraction, mortality, risk score
Background: data on the natural course and prognosis of tachycardia-induced cardiomyopathy (TICMP) and comparison with idiopathic dilated cardiomyopathies (IDCM) are scarce. Objective: To compare the clinical presentation, comorbidities, and long-term outcomes of TICMP patients with IDCM patients. Methods: a retrospective cohort study of patients hospitalized with new-onset TICMP or IDCM. The primary endpoint was a composite of death, myocardial infarction, thromboembolic events, assist device, heart transplantation, and ventricular tachycardia or fibrillation (VT/VF). The secondary endpoint was recurrent hospitalization due to heart failure (HF) exacerbation. Results: the cohort was comprised of 64 TICMP and 66 IDCM patients. The primary composite endpoint and all-cause mortality were similar between the groups during a median follow-up of ~6 years (36% versus 29%, p = 0.33 and 22% versus 15%, p = 0.15, respectively). Survival analysis showed no significant difference between TICMP and IDCM groups for the composite endpoint (p = 0.75), all-cause mortality (p = 0.65), and hospitalizations due to heart failure exacerbation. Nonetheless, the incidence of recurrent hospitalization was significantly higher in TICMP patients (incidence rate ratio 1.59; p = 0.009). Conclusions: patients with TICMP have similar long-term outcomes as those with IDCM. However, it portends a higher rate of HF readmissions, mostly due to arrhythmia recurrences.
Introduction Cardiac implantable electronic device (CIED) trans venous lead extraction (TLE) is technically challenging. Whether the use of a laser sheath reduces complications and improves outcomes is still in debate. We therefore aimed at comparing our experience with and without laser in a large referral center. Methods Information of all patients undergoing TLE was collected prospectively. We retrospectively compared procedural outcomes prior to the introduction of the laser sheath lead extraction technique to use of laser sheath. Results During the years 2007–2017, there were 850 attempted lead removals in 407 pts. Of them, 339 (83%) were extracted due to infection, device upgrade/lead malfunction in 42 (10%) cases, and other (7%). Complete removal (radiological success) of all leads was achieved in (88%). Partial removal was achieved in another 6% of the patients. Comparison of cases prior to and after laser technique introduction, showed that with laser, a significantly smaller proportion of cases required conversion to femoral approach [31/275 (6%) laser vs. 40/132 (15%) non-laser; p<0.001]. However, success rates of removal [259/275 (94%) vs. 124/132 (94%) respectively; p = 0.83] and total complication rates [35 (13%) vs. 19 (14%) respectively; p = 0.86] did not differ prior to and after laser use. In multivariate analysis, laser-assisted extraction was an independent predictor for no need for femoral extraction (OR = 0.39; 95% CI 0.23–0.69; p = 0.01). Conclusion Introduction of laser lead removal resulted in decreased need to convert to femoral approach, albeit without improving success rates or preventing major complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.