Acute pulmonary oedema is a serious complication of preeclampsia. Early detection of pulmonary edema in preeclampsia would improve fluid management and would also allow earlier detection of severe cases. The aim of this work is to evaluate the ability of thoracic fluid content measured by electrical cardiometry for early detection of pulmonary edema in parturients with preeclampsia. A prospective observational study included a cohort of preeclamptic parturients. On admission, lung ultrasound score was calculated, and thoracic fluid content was recorded using electrical cardiometry ICON device. Area under receiver operating characteristic (AUROC) curve was calculated for lung ultrasound score, thoracic fluid content for detection of pulmonary edema. Spearman correlation coefficient was calculated for correlation between lung ultrasound score and thoracic fluid content. Sixty patients were included in the study; of them, 6 patients (10%) required diuretics for pulmonary edema. Patients with pulmonary edema had higher lung ultrasound score and thoracic fluid content compared to other patients. Good correlation was reported between Lung ultrasound score and thoracic fluid content (r = 0.82). Thoracic fluid content and lung ultrasound score showed excellent diagnostic properties for pulmonary edema {AUROC: 0.941 (0.849-0.986), best cut-off value: 40 k ohm}, and {AUROC: 0.961 (0.887-0.994), best cut-off value of 15.7}. In parturients with preeclampsia, both lung ultrasound score and thoracic fluid content showed excellent properties for detection pulmonary edema. The high negative predictive value of both tests makes them useful screening tests to rule out pulmonary edema. The excellent correlation between both measures suggests that electrical cardiometry could be a promising surrogate to ultrasound for assessment of extravascular lung water.
BACKGROUND: Goal-directed fluid therapy (GDFT) improved patient outcomes in various surgical procedures; however, its role during mass brain resection was not well investigated. AIM: In this study, we evaluated a simple protocol based on intermittent evaluation of pulse pressure variation for guiding fluid therapy during brain tumour resection. METHODS: Sixty-one adult patients scheduled for supratentorial brain mass excision were randomized into either GDFT group (received intraoperative fluids guided by pulse pressure variation) and control group (received standard care). Both groups were compared according to the following: brain relaxation scale (BRS), mean arterial pressure, heart rate, urine output, intraoperative fluid intake, postoperative serum lactate, and length of hospital stay. RESULTS: Demographic data, cardiovascular data (mean arterial pressure and heart rate), and BRS were comparable between both groups. GDFT group received more intraoperative fluids {3155 (452) mL vs 2790 (443) mL, P = 0.002}, had higher urine output {2019 (449) mL vs 1410 (382) mL, P < 0.001}, and had lower serum lactate {0.9 (1) mmol versus 2.5 (1.1) mmol, P = 0.03} compared to control group. CONCLUSION: In conclusion, PPV-guided fluid therapy during supratentorial mass excision, increased intraoperative fluids, and improved peripheral perfusion without increasing brain swelling.
AIM: In this study we aimed to find out the heart rate variability measuring using electrical cardiometry is not reliable as a predictor for hypotension following spinal anesthesia in preeclamptic parturients undergoing elective cesarean section. METHODS: Electrical Cardiometry system was used to measure Heart rate variability (HRV) at five different time points before fluid loading (T0, baseline), after fluid loading (T1), 5 min after spinal anaesthesia (T2), 15 min after spinal anaesthesia (T3) and 30 min after spinal anaesthesia (T4). Traditional HRV measurement was determined using time-domain analysis. This Observational descriptive cohort study was conducted in Kasr Al-Ainy Hospital, Faculty of Medicine, Cairo University from February 2018 till June 2019, after approval of the Ethical Committee and written patients consent. RESULTS: The main finding of the current study is that heart rate variability measuring using electrical cardiometry is not reliable as a predictor for hypotension following spinal anaesthesia in preeclamptic parturients undergoing elective cesarean section. CONCLUSION: Heart rate variability cannot be used as a predictor for hypotension following spinal anaesthesia in preeclamptic patients undergoing elective caesarean section using electrical cardiometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.