Good control of hypertension was achieved in 8.3% with CBP (95% CI 4.8-11.8) and in 55.6% with ABPM (95% CI 49.3-61.9). The cost of one patient with good control of hypertension is almost four times higher with CBP than with ABPM (Euro 940 vs Euro 238). Reaching the gold standard (ABPM) involved an after-cost of Euro 115 per patient. The results for a 5% discount rate showed a saving of Euro 68,883 if ABPM was performed in all the patients included in the study (n = 241, Euro 285 per patient). An analysis of sensitivity, changing the discount rate and life expectancy indicated that ABPM provides a better CE ratio and a lower global cost. ABPM is more cost-effective than CBP. However, if we include the new treatment cost of poorly monitored patients, it is less cost-effective. Excellent control of hypertension is still an important challenge for all healthcare professionals, especially for those working in PC, where most monitoring of hypertensive patients takes place.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.