Cardiac ejection of blood into the aorta generates a reaction force on the body that can be measured externally via the ballistocardiogram (BCG). In this study, a commercial bathroom scale was modified to measure the BCGs of nine healthy subjects recovering from treadmill exercise. During the recovery, Doppler echocardiogram signals were obtained simultaneously from the left ventricular outflow tract of the heart. The percentage changes in root-mean-square (RMS) power of the BCG were strongly correlated with the percentage changes in cardiac output measured by Doppler echocardiography (R(2) = 0.85, n = 275 data points). The correlation coefficients for individually analyzed data ranged from 0.79 to 0.96. Using Bland-Altman methods for assessing agreement, the mean bias was found to be -0.5% (+/-24%) in estimating the percentage changes in cardiac output. In contrast to other non-invasive methods for trending cardiac output, the unobtrusive procedure presented here uses inexpensive equipment and could be performed without the aid of a medical professional.
A novel multiplanar reformatting (MPR) technique in three-dimensional transthoracic echocardiography (3D TTE) was used to precisely localize the prolapsed lateral segment of posterior mitral valve leaflet in a patient symptomatic with mitral valve prolapse (MVP) and moderate mitral regurgitation (MR) before undergoing mitral valve repair surgery. Transesophageal echocardiography was avoided based on the findings of this new technique by 3D TTE. It was noninvasive, quick, reproducible and reliable. Also, it did not need the time-consuming reconstruction of multiple cardiac images. Mitral valve repair surgery was subsequently performed based on the MPR findings and corroborated the findings from the MPR examination.
In long-term responders to CRT, there is alteration in the function of remodeled LV with acute interruption of CRT, without significant worsening of LV dyssynchrony. The role of different echocardiographic parameters in the assessment of LV dyssynchrony remains controversial. Even after long-term CRT reversely remodels the LV, the therapy needs to be continued uninterrupted for sustained benefits.
Background: Reference change value (RCV) is used to assess the significance of the difference between two measurements after accounting for pre-analytic, analytic, and within-subject variability. The objective of the current study was to define the RCV for global longitudinal strain (GLS) using different semi-automated software in standard clinical practice.Methods: Using a test-retest study design, we quantified the median coefficient of variation (CV) for GLS using AutoStrain and Automated Cardiac Motion Quantification (aCMQ) by Philips. Triplane left-ventricular ejection fraction (LVEF) was measured for comparison. Multivariable regression analysis was performed to determine factors influencing test-retest CV including image quality and the presence of segmental wall motion abnormalities (WMA). RCV was reported using a standard formula assuming two standard deviations for repeated measurements; results were also translated into Bayesian probability. Total measurement variation was described in terms of its three different components: pre-analytic (acquisition), analytic (measuring variation), and within-subject (biological) variation.Result: Of the 44 individuals who were screened, 41 had adequate quality for strain quantification. The mean age of the cohort was 56.4 ± 16.8 years, 41% female, LVEF was 55.8 ± 9.8% and the median and interquartile range for LV GLS was −17.2 [−19.3 to −14.8]%. Autostrain was more time efficient (80% less analysis time) and had a lower total median CV than aCMQ (CV = 7.4% vs. 17.6%, p < .001). The total CV was higher in patients with WMA (6.4% vs. 13.2%, p = .035). In non-segmental disease, the CV translates to a RCV of 15% (corresponding to a probability of real change of 80%). Assuming a within-subject variability of 4.0%, the component analysis identified that inter-reader variability accounts for 3.7% of the CV, while acquisition variability accounts for 4.0%.
Conclusion:Using test-retest analysis and CVs, we find that an RCV of 15% for GLS represents an optimistic estimate in routine clinical practice. Based on our results, a higher RCV of 17%-21% is needed in order to provide a high probability of clinically 1522
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.