Droplet and bubble dynamics and nucleate heat transfer in saturated FC-72 spray cooling were studied using a simulation model. The spray cooling system simulated consists of three droplet fluxes impinging on a smooth heater, where secondary nuclei outnumber the surface nuclei. Using the experimentally observed bubble growth rate on a smooth diamond heater, submodels were assumed based on physical reasoning for the number of secondary nuclei entrained by the impinging droplets, bubble puncturing by the impinging droplets, bubble merging, and the spatial distribution of secondary nuclei. The predicted nucleate heat transfer was in agreement with experimental findings. Dynamic aspects of the droplets and bubbles, which had been difficult to observe experimentally, and their ability in enhancing nucleate heat transfer were then discussed based on the results of the simulation. These aspects include bubble merging, bubble puncturing by impinging droplets, secondary nucleation, bubble size distribution, and bubble diameter at puncture. Simply increasing the number of secondary nuclei is not as effective in enhancing nucleate heat transfer as when it is also combined with increased bubble puncturing frequency by the impinging droplets. For heat transfer enhancement, it is desirable to have as many small bubbles and as high a bubble density as possible.
A heater designed to monitor surface temperature fluctuations during pool boiling and spray cooling experiments while the bubbles are simultaneously being observed has been fabricated and tested. The heat source was a transparent indium tin oxide (ITO) layer commercially deposited on a fused quartz substrate. Four copper-nickel thin film thermocouples (TFTCs) on the heater surface measured the surface temperature, while a thin layer of sapphire or synthetic fused silica provided electrical insulation between the TFTCs and the ITO. The TFTCs were microfabricated using the lift-off process to deposit the nickel and copper metal films. The TFTC elements were 50μm wide and overlapped to form a 25×25μm2 junction. A DAQ program recorded the TFTC voltages at a sampling rate of 50kHz and sent a trigger to a high-speed camera to synchronize bubble images with the surface temperature data. As the bubbles and their contact rings grew over the TFTC junction, correlations between bubble behavior and surface temperature changes were demonstrated.
Droplet and bubble dynamics and nucleate heat transfer in saturated FC-72 spray cooling were studied using a simulation model. Using the experimentally observed bubble growth rate, submodels were assumed based on physical reasoning for the number of secondary nuclei entrained by the impinging droplets, bubble puncturing by the impinging droplets, bubble merging and the spatial distribution of secondary nuclei. The predicted nucleate heat transfer was in agreement with experimental findings. Dynamic aspects of the droplets and bubbles, which had been difficult to observe experimentally, and their ability in enhancing nucleate heat transfer were then discussed based on the results of the simulation. These aspects include bubble merging, bubble puncturing by impinging droplets, secondary nucleation, bubble size distribution and bubble diameter at puncture. Simply increasing the number of secondary nuclei is not as effective in enhancing nucleate heat transfer as when it is also combined with increased bubble puncturing frequency by the impinging droplets. For heat transfer enhancement, it is desirable to have as many small bubbles and as high a bubble density as possible.
A heater designed to monitor surface temperature fluctuations during pool boiling and spray cooling experiments while the bubbles are simultaneously being observed has been fabricated and tested. The heat source was a transparent indium tin oxide (ITO) layer commercially deposited on a fused quartz substrate. Four copper-nickel thin film thermocouples (TFTCs) on the heater surface measured the surface temperature, while a thin layer of sapphire or synthetic fused silica provided electrical insulation between the TFTCs and the ITO. The TFTCs were micro-fabricated using the liftoff process to deposit the nickel and copper metal films. The TFTC elements were 50 μm wide and overlapped to form a 25 μm by 25 μm junction. TFTC voltages were recorded by a DAQ at a sampling rate of 50 kHz. A high-speed CCD camera recorded bubble images from below the heater at 2000 frames/second. From these images, the bubble outer diameter and contact ring diameter were clearly visible. A trigger sent to the camera by the DAQ program synchronized the bubble images and the surface temperature data. As the bubbles and their contact rings grew over the TFTC junction, correlations between bubble behavior and surface temperature changes were made. The 1–2°C temperature drops occurred as the contact ring moved over the TFTC junction during bubble growth and as the contact ring moved back over the TFTC junction during bubble departure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.