The magnet system is one of the key elements of a watt balance. For the new watt balance currently under construction at the National Institute of Standards and Technology, a permanent magnet system was chosen. We describe the detailed construction of the magnet system, first measurements of the field profile, and shimming techniques that were used to achieve a flat field profile. The relative change of the radial magnetic flux density is less than 10 −4 over a range of 5 cm. We further characterize the most important aspects of the magnet and give order of magnitude estimates for several systematic effects that originate from the magnet system.
A moiré pattern is created by superimposing two black-and-white or gray-scale patterns of regular geometry, such as two sets of evenly spaced lines. We observed an analogous effect between two transparent phase masks in a light beam which occurs at a distance. This phase moiré effect and the classic moiré effect are shown to be the two ends of a continuous spectrum. The phase moiré effect allows the detection of sub-resolution intensity or phase patterns with a transparent screen. When applied to x-ray imaging, it enables a polychromatic far-field interferometer (PFI) without absorption gratings. X-ray interferometry can non-invasively detect refractive index variations inside an object1–10. Current bench-top interferometers operate in the near field with limitations in sensitivity and x-ray dose efficiency2, 5, 7–10. The universal moiré effect helps overcome these limitations and obviates the need to make hard x-ray absorption gratings of sub-micron periods.
X-ray phase-contrast imaging is a promising approach for improving soft-tissue contrast and lowering radiation dose in biomedical applications. While current tabletop imaging systems adapt to common x-ray tubes and large-area detectors by employing absorptive elements such as absorption gratings or monolithic crystals to filter the beam, we developed nanometric phase gratings which enable tabletop x-ray far-field interferometry with only phase-shifting elements, leading to a substantial enhancement in the performance of phase contrast imaging. In a general sense the method transfers the demands on the spatial coherence of the x-ray source and the detector resolution to the feature size of x-ray phase masks. We demonstrate its capabilities in hard x-ray imaging experiments at a fraction of clinical dose levels and present comparisons with the existing Talbot-Lau interferometer and with conventional digital radiography.
In this paper, we show that quantum Hall resistance measurements using two terminals may be as precise as four-terminal measurements when applying superconducting split contacts. The described sample designs eliminate resistance contributions of terminals and contacts such that the size and complexity of next-generation quantized Hall resistance devices can be significantly improved.
We report the performance of a quantum Hall resistance standard based on epitaxial graphene maintained in a 5-T tabletop cryocooler system. This quantum resistance standard requires no liquid helium and can operate continuously, allowing year-round accessibility to quantized Hall resistance measurements. The ν = 2 plateau, with a value of RK/2, also seen as RH, is used to scale to 1 kΩ using a binary cryogenic current comparator (BCCC) bridge and a direct current comparator (DCC) bridge. The uncertainties achieved with the BCCC are such as those obtained in the state-of-the-art measurements using GaAs-based devices. BCCC scaling methods can achieve large resistance ratios of 100 or more, and while room temperature DCC bridges have smaller ratios and lower current sensitivity, they can still provide alternate resistance scaling paths without the need for cryogens and superconducting electronics. Estimates of the relative uncertainties of the possible scaling methods are provided in this report, along with a discussion of the advantages of several scaling paths. The tabletop system limits are addressed as are potential solutions for using graphene standards at higher currents.
Summary
Transmission electron microscopy (TEM) provides sub-nanometer-scale details in volumetric samples. Samples such as pathology tissue specimens are often stained with a metal element to enhance contrast, which makes them opaque to optical microscopes. As a result, it can be a lengthy procedure to find the region of interest inside a sample through sectioning. We describe micro-CT scouting for TEM that allows non-invasive identification of regions of interest within a block sample to guide the sectioning step. In a tissue pathology study, a bench-top micro-CT scanner with 10 μm resolution was used to determine the location of patches of the mucous membrane in osmium-stained human nasal scraping samples. Once the regions of interest were located, the sample block was sectioned to expose that location, followed by ultra-thin sectioning and TEM to inspect the internal structure of the cilia of the membrane epithelial cells with nanometer resolution. This method substantially reduced the time and labor of the search process from typically 20 sections for light microscopy (LM) to 3 sections with no added sample preparation.
This work presents precision measurements of quantized Hall array resistance devices using superconducting, crossover-free, multiple interconnections as well as graphene split contacts. These new techniques successfully eliminate the accumulation of internal resistances and leakage currents that typically occur at interconnections and crossing leads between interconnected devices. As a result, a scalable quantized Hall resistance array is obtained with a nominal value that is as precise and stable as that from single-element quantized Hall resistance standards.
We report the fabrication and measurement of top gated epitaxial graphene p-n junctions where exfoliated hexagonal boron nitride (h-BN) is used as the gate dielectric. The four-terminal longitudinal resistance across a single junction is well quantized at the von Klitzing constant with a relative uncertainty of 10−7. After the exploration of numerous parameter spaces, we summarize the conditions upon which these devices could function as potential resistance standards. Furthermore, we offer designs of programmable electrical resistance standards over six orders of magnitude by using external gating.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.