This paper investigated the hydraulic characteristics of the triangular central baffle (TCB) flume. Laboratory tests were carried out to determine the flume dimensions. The field applicability of the proposed portable device was examined by on-farm installation. According to the laboratory tests, when the contraction ratio, r, was less than 0.39, the flow capacity was not affected by the ratio between the flume’s floor height and the throat width. The laboratory analysis also showed that there was no significant effect of installing an entrance ramp on the stage-discharge relationship for r<0.39, while the entrance ramp increased the discharge capacity for r>0.39. The stage-discharge curve obtained based on the laboratory tests was verified using field data. The results revealed that the proposed portable flume could be used accurately to determine the flow through an unlined ditch. Practical suggestions were proposed to determine the distinguishing condition curve.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.