Objective Rapid, reliable, and affordable detection of Brucella species via the molecular methods remains a challenge. In recent years, loop-mediated isothermal amplification (LAMP) is a functional nucleic acid amplification technique offering a substitute to polymerase chain reaction (PCR). So, we compared the LAMP assay with the conventional PCR for the identification of common Brucella species in Iran. In this study, LAMP assay was comprehensively evaluated against the common PCR method. A group of specific LAMP primers were used to amplify a highly specific fragment from the sequence of the Brucella abortus, bcsp31 gene. Sensitivity and specificity values of tests were done with a set of 78 (50 Brucella and 28 non-Brucella) strains. Results A dilution series of B. abortus DNA indicated that the LAMP reaction could reliably detect 10 (fg/µl) DNA target copies per reaction within 36 min, which is 10 times greater than the PCR assay. In summary, we conclude that LAMP assay provide accurate and fast test results to identify of common Brucella species in low-complexity labs, mainly in low and lower middle income countries.
Objective: Rapid, reliable, and affordable detection of Brucella species via the molecular methods remains a challenge. In recent years, loop-mediated isothermal amplification (LAMP) is a functional nucleic acid amplification technique offering a substitute to polymerase chain reaction (PCR). So, we compared the LAMP assay with the conventional PCR for the identification of common Brucella species in Iran. In this study, LAMP assay was comprehensively evaluated against the common PCR method. A group of specific LAMP primers were used to amplify a highly specific fragment from the sequence of the Brucella abortus bcsp31 gene. Sensitivity and specificity values of tests were done with a set of 78 (50 Brucella and 28 non-Brucella) strains.Results: A dilution series of Brucella abortus DNA indicated that the LAMP reaction could reliably detect 10 (fg/µl) DNA target copies per reaction within 36 minute, which is 10 times greater than the PCR assay. In summary, we conclude that LAMP assay provide accurate and fast test results to identify of common Brucella species in low-complexity labs, mainly in low and lower middle income countries.
Objective: Rapid, reliable, and affordable detection of Brucella species via the molecular methods remains a challenge. In recent years, loop-mediated isothermal amplification (LAMP) is a functional nucleic acid amplification technique offering a substitute to polymerase chain reaction (PCR). So, we compared the LAMP assay with the conventional PCR for the identification of common Brucella species in Iran. In this study, LAMP assay was comprehensively evaluated against the common PCR method. A group of specific LAMP primers were used to amplify a highly specific fragment from the sequence of the Brucella abortus BCSP31 gene. Sensitivity and specificity values of tests were done with a set of 78 (50 Brucella and 28 non-Brucella) strains. Results: A dilution series of Brucella abortus DNA indicated that the LAMP reaction could reliably detect 10 (fg/µl) DNA target copies per reaction within 36 minute, which is 10 times greater than the PCR assay. In summary, we conclude that LAMP assay provide accurate and fast test results to identify of common Brucella species in low-complexity labs, mainly in low and lower middle income countries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.