BackgroundIn resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities.MethodEDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin). Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC) was used to determine the within subject variability of measured hemoglobin.ResultsOf 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p < 0.001). The Bland and Altman's limit of agreement was -0.389 - 0.644 g/dl with the mean difference being 0.127 (95% CI: 0.102-0.153) and a non-significant difference in variability between the two measurements (p = 0.843). After adjusting to assess the effect of other possible confounders such as sex, age and category of person, there was no significant difference in the hemoglobin determined by the HemoCue compared to Cyanmethemoglobin (coef = -0.127, 95% CI: -0.379 - 0.634).ConclusionHemoglobin determined by the HemoCue method is comparable to that determined by the other methods. The HemoCue photometer is therefore recommended for use as on-the-spot device for determining hemoglobin in resource poor setting.
BackgroundGastrointestinal and urinary tract pathogenic infections are aggravating the incidence and progression of the Human Immunodeficiency Virus (HIV) infection into Acquired Immune Deficiency Syndrome (AIDS) more especially in the developing countries. This study was conducted to assess the common gastrointestinal and urinary infections among HIV/AIDS patients at the Komfo Anokye Teaching Hospital (KATH) in Ghana between April and December 2008.FindingsThis work reports on gastrointestinal and urinary tract pathogenic infections among 500 HIV seropositive and 300 HIV seronegative patients. There was a 35% (175/500) prevalence of intestinal parasites among HIV seropositive patients compared to 4.3% (13/300) in HIV seronegative patients. Giardia lamblia and Cryptosporidium accounted for 19% (95/500) and 14% (70/500) respectively, while Schistosoma mansoni, Strongyloides stercoralis and hookworm together accounted for 2% (10/500) of intestinal parasitic infections among the HIV seropositive patients. There was no significant difference (p > 0.05) in urinary parasitic infection between HIV seropositive 1% (2/500) and seronegative patients 0.7% (2/300). Most, 60 (86%) out of 70, of the urinary tract infection among the HIV seropositive patients was due to bacteria with E. coli being the most predominant isolate, 28 (47%) out of 60. There was no significant difference in infections based on age and gender.ConclusionG. lamblia and Cryptosporidium were the most common gastrointestinal parasites detected while bacteria accounted for majority of the urinary tract infections among the HIV seropositive patients at the hospital.
The RTS,S/AS01 malaria vaccine (Mosquirix) reduces the incidence of Plasmodium falciparum malaria and is intended for routine administration to infants in Sub-Saharan Africa. We evaluated the immunogenicity and safety of 10-valent pneumococcal non-typeable Haemophilus influenzae protein D conjugate vaccine (PHiD-CV; Synflorix) and human rotavirus vaccine (HRV; Rotarix) when co-administered with RTS,S/AS01 (www.clinicaltrials.gov NCT01345240) in African infants. 705 healthy infants aged 8–12 weeks were randomized to receive three doses of either RTS,S/AS01 or licensed hepatitis B (HBV; Engerix B) vaccine (control) co-administered with diphtheria-tetanus-acellular pertussis-Haemophilus influenzae type-b-conjugate vaccine (DTaP/Hib) and trivalent oral poliovirus vaccine at 8–12-16 weeks of age, because DTaP/Hib was not indicated before 8 weeks of age. The vaccination schedule can still be considered broadly applicable because it was within the age range recommended for EPI vaccination. PHiD-CV or HRV were either administered together with the study vaccines, or after a 2-week interval. Booster doses of PHiD-CV and DTaP/Hib were administered at age 18 months.Non-inferiority of anti-HBV surface antigen antibody seroprotection rates following co-administration with RTS,S/AS01 was demonstrated compared to the control group (primary objective). Pre-specified non-inferiority criteria were reached for PHiD-CV (for 9/10 vaccine serotypes), HRV, and aP antigens co-administered with RTS,S/AS01 as compared to HBV co-administration (secondary objectives). RTS,S/AS01 induced a response to circumsporozoite protein in all groups. Pain and low grade fever were reported more frequently in the PHiD-CV group co-administered with RTS,S/AS01 than PHiD-CV co-administered with HBV. No serious adverse events were considered to be vaccine-related. RTS,S/AS01 co-administered with pediatric vaccines had an acceptable safety profile. Immune responses to RTS,S/AS01 and to co-administered PHiD-CV, pertussis antigens and HRV were satisfactory.
Nanostructured surfaces, or metasurfaces, allow exquisite control of linear and nonlinear optical processes by reshaping the amplitude, phase, and polarization of electric and magnetic fields near wavelength-scale heterogeneities. Recently, metasurfaces have broken new ground in high-field attosecond science where they have been utilized to amplify the emission of high-order harmonics of femtosecond infrared laser pulses, a notoriously inefficient process, by enhancing the incident field, and to shape the emitted high harmonics in space. Here we show control of the polarization and phase of high harmonics with a plasmonic metasurface. We design and fabricate perpendicularly aligned rectangular gold antennas on a silicon crystal that generate circularly polarized deep-ultraviolet high harmonics, from a circularly polarized infrared driver, providing a simple path for achieving circular emission from patterned crystals. Our metasurface enhances the circularly polarized harmonics up to ∼ 43 times when compared to the unpatterned surface, where harmonics are quenched. Looking forward, circularly polarized high harmonics will be useful tools for sensing chiral laser–matter interactions and magnetic materials. Our approach paves the way for polarization control at even shorter, extreme ultraviolet, wavelengths.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.