Time resolved phase-contrast magnetic resonance imaging 4D-PCMR (also called 4D Flow MRI) data while capable of non-invasively measuring blood velocities, can be affected by acquisition noise, flow artifacts, and resolution limits. In this paper, we present a novel method for merging 4D Flow MRI with computational fluid dynamics (CFD) to address these limitations and to reconstruct de-noised, divergence-free high-resolution flow-fields. Proper orthogonal decomposition (POD) is used to construct the orthonormal basis of the local sampling of the space of all possible solutions to the flow equations both at the low-resolution level of the 4D Flow MRI grid and the high-level resolution of the CFD mesh. Low-resolution, de-noised flow is obtained by projecting in-vivo 4D Flow MRI data onto the low-resolution basis vectors. Ridge regression is then used to reconstruct high-resolution de-noised divergence-free solution. The effects of 4D Flow MRI grid resolution, and noise levels on the resulting velocity fields are further investigated. A numerical phantom of the flow through a cerebral aneurysm was used to compare the results obtained using the POD method with those obtained with the state-of-the-art de-noising methods. At the 4D Flow MRI grid resolution, the POD method was shown to preserve the small flow structures better than the other methods, while eliminating noise. Furthermore, the method was shown to successfully reconstruct details at the CFD mesh resolution not discernible at the 4D Flow MRI grid resolution. This method will improve the accuracy of the clinically relevant flow-derived parameters, such as pressure gradients and wall shear stresses, computed from in-vivo 4D Flow MRI data.
The scarcity of organs for transplant has led to large waiting lists of very sick patients. In drug development, the time required for human trials greatly increases the time to market. Drug companies are searching for alternative environments where the in − vivo conditions can be closely replicated. Both these problems could be addressed by manufacturing artificial human tissue. Recently, researchers in tissue engineering have developed tissue generation methods based on 3-D printing to fabricate artificial human tissue. Broadly, these methods could be classified as laser-assisted and laser free. The former have very fine spatial resolutions (10s of µm) but suffer from slow speed ( < 10 2 drops per second). The later have lower spatial resolutions (100s of µ m) but are very fast (up to 5 × 10 3 drops per second). In this paper we review state-of-the-art methods in each of these classes and provide a comparison based on reported resolution, printing speed, cell density and cell viability.
Dynamic Mode Decomposition (DMD) is a data-driven method to analyze the dynamics, first applied to fluid dynamics. It extracts modes and their corresponding eigenvalues, where the modes are spatial fields that identify coherent structures in the flow and the eigenvalues describe the temporal growth/decay rates and oscillation frequencies for each mode. The recently introduced compressed sensing DMD (csDMD) reduces computation times and also has the ability to deal with sub-sampled datasets. In this paper, we present a similar technique based on discrete cosine transform to reconstruct the fully-sampled dataset (as opposed to DMD modes as in csDMD) from sub-sampled noisy and gappy data using l 1 minimization. The proposed method was benchmarked against csDMD in terms of denoising and gap-filling using three datasets. The first was the 2-D time-resolved plot of a double gyre oscillator which has about nine oscillatory modes. The second dataset was derived from a Duffing oscillator. This dataset has several modes associated with complex eigenvalues which makes them oscillatory. The third dataset was taken from the 2-D simulation of a wake behind a cylinder at Re = 100 and was used for investigating the effect of changing various parameters on reconstruction error. The Duffing and 2-D wake datasets were tested in presence of noise and rectangular gaps. While the performance for the double-gyre dataset is comparable to csDMD, the proposed method performs substantially better (lower reconstruction error) for the dataset derived from the Duffing equation and also, the 2-D wake dataset according to the defined reconstruction error metrics.
In this research, we investigate the application of Dynamic Mode Decomposition combined with Kalman Filtering, Smoothing, and Wavelet Denoising (DMD-KF-W) for denoising time-resolved data. We also compare the performance of this technique with state-of-the-art denoising methods such as Total Variation Diminishing (TV) and Divergence-Free Wavelets (DFW), when applicable. Dynamic Mode Decomposition (DMD) is a data-driven method for finding the spatio-temporal structures in time series data. In this research, we use an autoregressive linear model resulting from applying DMD to the time-resolved data as a predictor in a Kalman Filtering-Smoothing framework for the purpose of denoising. The DMD-KF-W method is parameter-free and runs autonomously. Tests on numerical phantoms show lower error metrics when compared to TV and DFW, when applicable. In addition, DMD-KF-W runs an order of magnitude faster than DFW and TV. In the case of synthetic datasets, where the noise-free datasets were available, our method was shown to perform better than TV and DFW methods (when applicable) in terms of the defined error metric.
Flow fields in cerebral aneurysms can be measured in vivo with phase-contrast MRI (4D Flow MRI), providing 3D anatomical magnitude images as well as 3-directional velocities through the cardiac cycle. The low spatial resolution of the 4D Flow MRI data, however, requires the images to be co-registered with higher resolution angiographic data for better segmentation of the blood vessel geometries to adequately quantify relevant flow descriptors such as wall shear stress or flow residence time. Time-of-Flight Magnetic Resonance Angiography (TOF MRA) is a non-invasive technique for visualizing blood vessels without the need to administer contrast agent. Instead TOF uses the blood flow-related enhancement of unsaturated spins entering into an imaging slice as means to generate contrast between the stationary tissue and the moving blood. Because of the higher resolutions, TOF data are often used to assist with the segmentation process needed for the flow analysis and Computational Fluid Dynamics (CFD) modeling. However, presence of slow moving and recirculating blood flow such as in brain aneurysms, especially regions where the blood flow is not perpendicular to the image plane, causes signal loss in these regions. In this work a 3D Curvelet Transform-based image fusion approach is proposed for signal loss artifact reduction of TOF volume data. Experiments show the superiority of the proposed approach in comparison to other multi-resolution 3D Wavelet-based image fusion methodologies. The proposed approach can further facilitate model-based fluid analysis and pre/post-operative treatment of patients with brain aneurysms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.