We present a new compilation of Type Ia supernovae (SNe Ia), a new data set of low-redshift nearby-Hubble-flow SNe, and new analysis procedures to work with these heterogeneous compilations. This ''Union'' compilation of 414 SNe Ia, which reduces to 307 SNe after selection cuts, includes the recent large samples of SNe Ia from the Supernova Legacy Survey and ESSENCE Survey, the older data sets, as well as the recently extended data set of distant supernovae observed with the Hubble Space Telescope (HST ). A single, consistent, and blind analysis procedure is used for all the various SN Ia subsamples, and a new procedure is implemented that consistently weights the heterogeneous data sets and rejects outliers. We present the latest results from this Union compilation and discuss the cosmological constraints from this new compilation and its combination with other cosmological measurements (CMB and BAO). The constraint we obtain from supernovae on the dark energy density is à ¼ 0:713 þ0:027 À0:029 (stat) þ0:036 À0:039 (sys), for a flat, ÃCDM universe. Assuming a constant equation of state parameter, w, the combined constraints from SNe, BAO, and A CMB give w ¼ À0:969 þ0:059 À0:063 (stat) þ0:063 À0:066 (sys). While our results are consistent with a cosmological constant, we obtain only relatively weak constraints on a w that varies with redshift. In particular, the current SN data do not yet significantly constrain w at z > 1. With the addition of our new nearby Hubble-flow SNe Ia, these resulting cosmological constraints are currently the tightest available.
Although over the last 20 years diffusion MRI has become an established technique with a great impact on health care and neurosciences, like any other MRI technique it remains subject to artifacts and pitfalls. In addition to common MRI artifacts, there are specific problems that one may encounter when using MRI scanner gradient hardware for diffusion MRI, especially in terms of eddy currents and sensitivity to motion. In this article we review those artifacts and pitfalls on a qualitative basis, and introduce possible strategies that have been developed to mitigate or overcome them.
With Transmit SENSE, we demonstrate the feasibility of uniformly exciting a volume such as the human brain at 7T through the use of an original minimalist transmit k-space coverage, referred to as ''k T -points.'' Radio-frequency energy is deposited only at a limited number of k-space locations in the vicinity of the center to counteract transmit sensitivity inhomogeneities. The resulting nonselective pulses are short and need little energy compared to adiabatic or other B þ 1 -robust pulses available in the literature, making them good candidates for shortrepetition time 3D sequences at high field. Experimental verification was performed on three human volunteers at 7T by means of an 8-channel transmit array system. On average, whereas the standard circularly polarized excitation resulted in a 33%-flip angle spread (standard deviation over mean) throughout the brain, and a static radio-frequency shim showed flip angle variations of 17% and up, application of k T -point-based excitations demonstrated excellent flip angle uniformity (8%) for a small target flip angle and with sub-millisecond durations. Magn Reson Med 67:72-80,
Our findings demonstrate partial format invariance of individual number codes that is compatible with more numerous but more broadly tuned populations for nonsymbolic than for symbolic numbers, as postulated by recent computational models. In more general terms, our results illustrate the potential of functional magnetic resonance imaging pattern recognition to understand the detailed format of representations within a single semantic category, and beyond sensory cortical areas for which columnar architectures are well established.
Parallel transmission is a very promising candidate technology to mitigate the inevitable radiofrequency (RF) field inhomogeneity in magnetic resonance imaging (MRI) at ultra-high field (UHF). For the first few years, pulse design utilizing this technique was expressed as a least squares problem with crude power regularizations aimed at controlling the specific absorption rate (SAR), hence the patient safety. This approach being suboptimal for many applications sensitive mostly to the magnitude of the spin excitation, and not its phase, the magnitude least squares (MLS) problem then was first formulated in 2007. Despite its importance and the availability of other powerful numerical optimization methods, the MLS problem yet has been faced almost exclusively by the pulse designer with the so-called variable exchange method. In this paper, we investigate various two-stage strategies consisting of different initializations and nonlinear programming approaches, and incorporate directly the strict SAR and hardware constraints. Several schemes such as sequential quadratic programming (SQP), interior point (I-P) methods, semidefinite programming (SDP) and magnitude squared least squares (MSLS) relaxations are studied both in the small and large tip angle regimes with RF and static field maps obtained in-vivo on a human brain at 7 Tesla. Convergence and robustness of the different approaches are analyzed, and recommendations to tackle this specific problem are finally given. Small tip angle and inversion pulses are returned in a few seconds and in under a minute respectively while respecting the constraints, allowing the use of the proposed approach in routine.
Adult late-onset Pompe disease is most often a slowly progressive limb-girdle and spine extensor muscle dystrophy, due to defective lysosomal acid maltase. With the exception of the few patients who present with a dramatically accelerated clinical course, standard diagnostic imaging fail to detect and evaluate disease progression between two successive visits. In muscle dystrophy of very rapid evolution, like the Duchenne disease, quantitative NMR imaging has successfully demonstrated its capacity to objectivate both disease activity and degenerative changes progression over short follow-up periods. The purpose of this retrospective monocentric open-label study was to investigate whether quantitative NMR imaging can monitor disease progression in adult Pompe patients despite its very slow nature. Quantitative imaging of Pompe patients succeeded in demonstrating that muscle fatty infiltration increased on average by 0.9 %/year, with the hamstring and adductor muscles showing the fastest degradation. Muscle water T2 mapping revealed that 32 % of all muscles had abnormally high T2 in at least one of two successive examinations. When muscle water T2 was abnormal, fatty degenerative changes were further increased by 0.61 %/year. Enzyme replacement therapy resulted in 0.68 %/year slowdown of the muscle fatty infiltration, in both muscles with normal and high T2s.Electronic supplementary materialThe online version of this article (doi:10.1007/s10545-015-9825-9) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.