Legionella pneumophila is known as the causative agent of Legionnaires’ disease and free-living amoebae (FLA) can serve as vehicles for legionellae. The aim of this study was to screen industrial waters for the occurrence of FLA and their co-occurrence with legionellae. A total of 201 water samples, including 129 cooling waters and 72 process waters, and 30 cooling lubricants were included in the study. Treated waters were screened periodically, pre and post treatment. Altogether, 72.6% of the water samples were positive for FLA, acanthamoebae being most prevalent (in 23.9% of the samples) followed by Vermamoeba vermiformis (19.4%). Only one cooling lubricant was positive (Acanthamoeba genotype T4). Legionella spp. were detected in 34.8% of the water samples and in 15% in high concentrations (>1000 CFU/100 ml). Altogether, 81.4% of the Legionella-positive samples were positive for FLA by standard methods. By applying a highly sensitive nested PCR to a representative set of random samples it was revealed that Legionella spp. always co-occurred with Acanthamoeba spp. Although the addition of disinfectants did influence amoebal density and diversity, treated waters showed no difference concerning FLA in the interphases of disinfection. It appears that FLA can re-colonize treated waters within a short period of time.
Aims: Open cooling towers are frequent sources of infections with Legionella pneumophila. The gold standard for the detection of Leg. pneumophila is based on cultivation lasting up to 10 days and detecting only culturable cells. Alternative fluorescence in situ hybridization (FISH) protocols have been proposed, but they result in faint fluorescence signals and lack specificity because of cross‐hybridization with other Legionella species. Our aim was thus to develop a new FISH protocol for rapid and specific detection of Leg. pneumophila in water samples. Methods and Results: A novel catalysed reporter deposition FISH (CARD‐FISH) protocol for the detection of Leg. pneumophila was developed, which significantly enhanced signal intensity as well as specificity of the probe through the use of a novel competitor probe. The developed protocol was compared with the culture method for monitoring the seasonal development of culturable and nonculturable Leg. pneumophila in two hospital cooling tower systems. Seasonal fluctuations of Leg. pneumophila concentrations detected via CARD‐FISH were related to the development of the total bacterial community in both cooling towers, with temperature and biocide as the main factors controlling this development. Conclusions: Our results clearly showed that the majority of the Leg. pneumophila cells were in a nonculturable state. Thus, detection of Leg. pneumophila with culture methods may underestimate the total numbers of Leg. pneumophila present. Significance and Impact of the Study: Rapid, sensitive and specific detection and quantification of Leg. pneumophila in water systems is prerequisite for reliable risk estimation. The new protocol significantly improves current methodology and can be used to monitor and screen for Leg. pneumophila concentrations in cooling towers or other water systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.