Thermoplastic polymer matrix composites with continuous carbon fibre reinforcements are of crucial relevance in automotive industry. The mix of high performance and cost effective manufacturing makes them attractive for high volume production. However, it could be shown that production integrated end of line quality control is of strong importance to ensure continuous and traceable part quality. Besides, typical non destructive testing method specifications, higher production volumes additionally require short testing times. Herein, the application of active thermography as end of line quality control in composite production is evaluated and compared with results obtained by X-ray radiometry. It could be revealed that transient pulse phase thermography is a powerful tool to analyse part quality of continuous thermoplastic polymer matrix composites in short testing times.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.