BackgroundThe aim of this in study was the evaluation of treatment outcomes after using a hybrid hyrax-facemask combination in growing class III patients.MethodsTreatment of 16 children (mean age 9.5 ± 1.3 years) was investigated clinically and by means of pre- and post-treatment cephalograms. Changes in sagittal and vertical, and dental and skeletal values were evaluated and tested for statistically significant differences.ResultsAll mini-implants remained stable during treatment. Mean treatment duration was 5.8 ± 1.7 months. There was a significant improvement in skeletal sagittal values: SNA, +2.0°; SNB, -1.2°; ANB, +3.2°; WITS appraisal, +4.1 mm and overjet, +2.7 mm. No significant changes were found concerning vertical skeletal relationships and upper incisor inclination. In relation to A point, the upper first molars moved mesially about 0.4 mm (P = 0.134).ConclusionsThe hybrid hyrax-facemask combination seems to be effective for orthopaedic treatment in growing class III patients. Unwanted maxillary dental movements can be avoided due to stable skeletal anchorage.
The clinical impression was confirmed by the measurements taken in this study. The final results following lingual orthodontic treatment using individualized brackets correlate satisfactorily with the therapeutic set-ups.
Objective: To investigate whether resonance frequency analysis (RFA) is suitable to measure orthodontic mini-implant stability. Implant size significantly affects the level of resonance frequency. Regarding the operating mode of RFA, it has to be proven whether the resonance frequency of mini-implants in bone fits the range of frequency emitted by the Osstell ISQ device. Material and Methods: For this purpose the SmartPegs in the Osstell ISQ device were modified to fit with the inner screw thread of orthodontic mini-implants, and 110 mini-implants were inserted into porcine pelvic bone. RFA was performed parallel and perpendicular to the run of superficial bone fibers. A suitability test, Periotest, was also performed in the same directions. Compacta thickness was measured using cone-beam computed tomography. Correlation tests and linear regression analysis were carried out between the three methods. Results: The RFA showed a mean Implant Stability Quotient value of 36.36 6 2.67, and the Periotest mean value was 22.10 6 1.17. The differences between the two directions of measurement were statistically significant (P . .001) for RFA and the Periotest. There was a high correlation between RFA and the Periotest (r 5 20.90) and between RFA and compacta thickness (r 5 0.71). The comparison between the Periotest and compacta thickness showed a correlation coefficient of r 5 20.64. Conclusion:The present results suggest that RFA is feasible as a measurement method for orthodontic mini-implant stability. As a consequence, it could be used for clinical evaluation of current stability and allow stability-related loading of mini-implants to reduce the failure rate. (Angle Orthod. 2013;83:230-238.)
Objective: To assess the effect of wear-time recording on subjective and objective wear time. Materials and Methods: This study retrospectively examined a group of 18 patients and a control group of 14 patients at four appointments over 168 days. The patients were treated with removable appliances with embedded TheraMon-microsensors to be worn for 15 hours per day. The study group was not told about the microsensor until the first appointment after fitting of the appliance. At each appointment patients were asked about their subjective wear time and afterward were told about the objective wear time. The existence of the microsensor was revealed to the control group when the appliance was fitted. Objective wear time was also announced at every appointment. Results: Mean wear times did not significantly differ between groups at any appointment or regarding overall wear time. Highly significant differences between subjective and objective wear time were found when patients did not know that their wear time had been monitored. Conclusion: Mean wear times assessed in this study concur with data of previous studies. Patients tend to overestimate their wear times but become more realistic once they know wear time is being monitored. Objective measurement of wear time allows a more realistic view of compliance by patient and orthodontist. Knowing that wear time is recorded does not necessarily increase the amount of time removable appliances are worn by the patient.
Background: It remains unclear how physical activity (PA) interventions need to be designed to reach older adults and to be widely accepted in this target group. The aim of this study was to assess the acceptance of a web-based PA program, including individual intervention components as well as relevant contextual factors, and to specify requirements for future interventions. Methods: Two hundred sixty-six participants of a PA intervention completed a questionnaire covering individual program components (content, structure, and context). Further, 25 episodic guided interviews focusing on reasons for (non-) participation were conducted with 8 participants and 17 non-participants. Following qualitative content analysis, different requirements were identified and organized based on the social-ecological model, resulting in a profile of requirements. Results: Based on the participants' and non-participants' statements, six different levels of requirements affecting acceptance of and successful participation in a web-based PA intervention were identified. The individual fit was influenced by an interaction of different factors at the intrapersonal, sociocultural, content, spatial, digital and organizational levels. Several ageand gender-specific requirements were noted in the interviewed older adults. Men and women, as well as younger (< 70 years) and older (≥70 years) adults differed in terms of perceived enjoyment and benefits of socializing while exercising together, the time expenditure perceived to be acceptable, previous digital skills, as well as in perceptions that ambience and accessibility of exercise facilities in the neighborhood were important.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.