Microfluidic devices have an established role in the study of platelets and coagulation factors in thrombosis, with potential diagnostic applications. However, few microfluidic devices have assessed the contribution of neutrophils to thrombus formation, despite increasing knowledge of neutrophils’ importance in cardiovascular thrombosis. We describe a thromboinflammation model which uses straight channels, lined with fixed human umbilical vein endothelial cells, after treatment with tumour necrosis factor-alpha. Re-calcified whole blood is perfused over the endothelium at venous and arterial shear rate. Neutrophil adhesion, platelet and fibrin thrombus formation, is measured over time by the addition of fluorescent antibodies to a whole blood sample. Fixed endothelium retains surface expression of adhesion molecules ICAM-1 and E-Selectin. Neutrophils adhere preferentially to platelet thrombi on the endothelium. Inhibitors of neutrophil adhesion and anti-inflammatory agents, such as isoquercetin, decrease neutrophil adhesion. Our model offers the advantage of the use of (1) fixed endothelium, (2) whole blood, instead of isolated neutrophils, and (3) a small amount of blood (1 mL). The characteristics of this thromboinflammation model provide the potential for further development for drug screening and point-of-care applications.
Microfluidic devices have become an integral method of cardiovascular research as they enable the study of shear force in biological processes, such as platelet function and thrombus formation. Furthermore, microfluidic chips offer the benefits of ex vivo testing of platelet adhesion using small amounts of blood or purified platelets. Microfluidic chips comprise flow channels of varying dimensions and geometries which are connected to a syringe pump. The pump draws blood or platelet suspensions through the channel(s) allowing for imaging of platelet adhesion and thrombus formation by fluorescence microscopy. The chips can be fabricated from various blood-compatible materials. The current protocol uses commercial plastic or in-house polydimethylsiloxane (PDMS) chips. Commercial biochips offer the advantage of standardization whereas in-house chips offer the advantage of decreased cost and flexibility in design. Microfluidic devices are a powerful tool to study the biorheology of platelets and other cell types with the potential of a diagnostic and monitoring tool for cardiovascular diseases.
Background: Atherosclerosis is characterized by lipid deposition, monocyte infiltration and foam cell formation in the artery wall. Translocator protein (TSPO) is abundantly expressed in lipid rich tissues. Recently, TSPO has been identified as a potential diagnostic tool in cardiovascular disease. The purpose of this study was to determine if the TSPO ligand, 18 F-PBR111, can identify early atherosclerotic lesions and if TSPO expression can be used to identify distinct macrophage populations during lesion progression.Methods and Results: ApoE -/mice were maintained on a high-fat diet for 3 or 12 weeks. C57BL/6J mice maintained on chow diet served as controls. Mice were administered 18 F-PBR111 intravenously and PET/CT imaged. After euthanasia, aortas were isolated, fixed and optically cleared. Cleared aortas were immunostained with DAPI, and fluorescently labelled with antibodies to-TSPO, the tissue resident macrophage marker F4/80 and the monocyte-derived macrophage marker CD11b. TSPO expression and the macrophage markers were visualised in fatty streaks and mature lesions by light sheet microscopy. While tissue resident F4/80 + macrophages were evident in the arteries of animals without atherosclerosis, no CD11b + macrophages were observed in these animals. In contrast, mature plaques had high CD11b and low F4/80 expression. A ~3-fold increase in the uptake of 18 F-PBR111 was observed in the aortas of atherosclerotic mice relative to controls. Conclusions:Imaging of TSPO expression is a new approach for studying atherosclerotic lesion progression and inflammatory cell infiltration. The TSPO ligand, 18 F-PBR111, is a potential clinical diagnostic tool for the detection and quantification of atherosclerotic lesion progression in humans..
BACKGROUND: Neutrophil migration is critical to the initiation and resolution of inflammation. Macrophage-1 antigen (Mac-1; CD11b/CD18, αMβ2) is a leukocyte integrin essential for firm adhesion to endothelial ICAM-1 (intercellular adhesion molecule 1) and migration of neutrophils in the shear forces of the circulation. PDI (protein disulfide isomerase) has been reported to influence neutrophil adhesion and migration. We aimed to elucidate the molecular mechanism of PDI control of Mac-1 affinity for ICAM-1 during neutrophil migration under fluid shear. METHODS: Neutrophils isolated from whole blood were perfused over microfluidic chips coated with ICAM-1. Colocalization of Mac-1 and PDI on neutrophils was visualized by fluorescently labeled antibodies and confocal microscopy. The redox state of Mac-1 disulfide bonds was mapped by differential cysteine alkylation and mass spectrometry. Wild-type or disulfide mutant Mac-1 was expressed recombinantly in Baby Hamster Kidney cells to measure ligand affinity. Mac-1 conformations were measured by conformation-specific antibodies and molecular dynamics simulations. Neutrophils crawling on immobilized ICAM-1 were measured in presence of oxidized or reduced PDI, and the effect of PDI inhibition using isoquercetin on neutrophil crawling on inflamed endothelial cells was examined. Migration indices in the X- and Y-direction were determined and the crawling speed was calculated. RESULTS: PDI colocalized with high-affinity Mac-1 at the trailing edge of stimulated neutrophils when crawling on ICAM-1 under fluid shear. PDI cleaved 2 allosteric disulfide bonds, C169-C176 and C224-C264, in the βI domain of the β2 subunit, and cleavage of the C224-C264 disulfide bond selectively controls Mac-1 disengagement from ICAM-1 under fluid shear. Molecular dynamics simulations and conformation-specific antibodies reveal that cleavage of the C224-C264 bond induces conformational change and mechanical stress in the βI domain. This allosterically alters the exposure of an αI domain epitope associated with a shift of Mac-1 to a lower-affinity state. These molecular events promote neutrophil motility in the direction of flow at high shear stress. Inhibition of PDI by isoquercetin reduces neutrophil migration in the direction of flow on endothelial cells during inflammation. CONCLUSIONS: Shear-dependent PDI cleavage of the neutrophil Mac-1 C224-C264 disulfide bond triggers Mac-1 de-adherence from ICAM-1 at the trailing edge of the cell and enables directional movement of neutrophils during inflammation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.