AimsTo collect information on the use of the Reveal implantable loop recorder (ILR) in the patient care pathway and to investigate its effectiveness in the diagnosis of unexplained recurrent syncope in everyday clinical practice.Methods and resultsProspective, multicentre, observational study conducted in 2006–2009 in 10 European countries and Israel. Eligible patients had recurrent unexplained syncope or pre-syncope. Subjects received a Reveal Plus, DX or XT. Follow up was until the first recurrence of a syncopal event leading to a diagnosis or for ≥1 year. In the course of the study, patients were evaluated by an average of three different specialists for management of their syncope and underwent a median of 13 tests (range 9–20). Significant physical trauma had been experienced in association with a syncopal episode by 36% of patients. Average follow-up time after ILR implant was 10 ± 6 months. Follow-up visit data were available for 570 subjects. The percentages of patients with recurrence of syncope were 19, 26, and 36% after 3, 6, and 12 months, respectively. Of 218 events within the study, ILR-guided diagnosis was obtained in 170 cases (78%), of which 128 (75%) were cardiac.ConclusionA large number of diagnostic tests were undertaken in patients with unexplained syncope without providing conclusive data. In contrast, the ILR revealed or contributed to establishing the mechanism of syncope in the vast majority of patients. The findings support the recommendation in current guidelines that an ILR should be implanted early rather than late in the evaluation of unexplained syncope.
General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.-Users may download and print one copy of any publication from the public portal for the purpose of private study or research-You may not further distribute the material or use it for any profit-making activity or commercial gain-You may freely distribute the URL identifying the publication in the public portal Take down policy If you believe that this document breaches copyright, please contact us providing details, and we will remove access to the work immediately and investigate your claim.
The arithmetic test was associated with a significantly higher heart rate for CLS than for AS, showing a greater sensitivity of CLS-based rate adaptation to mental stress. Performance during physical stress was comparable. Patients preferred CLS.
Background: Echocardiography is a common method to measure heart size in dogs. The heart dimensions are influenced by body weight (BW) and potentially by breed. Objectives: To establish BW-dependent prediction intervals (PIs) of the left ventricular (LV) linear dimensions in a population of dogs of many breeds in multicenter environment, and to identify breeds deviating from these intervals. Dogs: Seven thousand six hundred and fifty-one dogs. Methods: Retrospectively, data from heart screens conducted between 2009 and 2016 were included. Cardiac dimensional PIs were generated using allometric scaling including all nonsighthound dogs and values were compared to previously published PIs. The values measured in dogs of respective breeds, including sighthounds, were then compared to the overall nonsighthound PIs to identify deviant breeds. The interobservervariability of the measurements was determined using the explained residual variance. Results: Prediction intervals for the nonsighthound dogs were in agreement with previously published cardiac PIs, although the upper limits of the generated PIs of our study were slightly below those currently applied (except the interventricular septum in systole and the left ventricular free wall in diastole below 10.0 kg and 15.0 kg, respectively). Values measured in the nonsighthound breed Newfoundland deviated for most dimensions. Most of the sighthound breeds analyzed had greater cardiac dimensions, with the exception of the Irish Wolfhound. Conclusion and Importance: Findings of our study reinforces the value of BWdependent PIs for cardiac dimensions in dogs and suggest that these PIs are valid for most nonsighthound breeds, but not the sighthound breeds.
Patient-alert features are a useful additional tool facilitating early detection of serious ICD complications, but they do not substitute for regular ICD follow-up, because of their low sensitivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.