Background: The use of bone marrow–derived mesenchymal stem cells (BMSCs) in cartilage repair procedures circumvents some of the limitations of autologous chondrocyte implantation (ACI), but long-term outcomes for this newer procedure are lacking. The authors previously reported comparable outcomes for the 2 procedures at 2-year follow-up. Purpose/Hypothesis: The purpose was to compare the long-term clinical outcomes of ACI versus BMSCs. It was hypothesized that there would be no significant difference between the groups in terms of patient-reported outcome scores and safety outcomes at 10-year follow-up. Study Design: Cohort study; Level of evidence, 2. Methods: Seventy-two patients who underwent either ACI or BMSC implantation—matched in terms of age and lesion site— were followed up to a median of at least 10 years. Patients were assessed with the 36-item Short Form Health Survey (SF-36), the International Knee Documentation Committee knee evaluation form, the Lysholm Knee Score, and the Tegner Activity Scale. In addition, information was obtained regarding any additional surgical procedures as well as safety data, with particular attention to infection and tumor formation. Results: There was an improvement in all patient-reported outcomes scores apart from the Mental Component Summary of the SF-36 after cartilage repair surgery. There was no significant difference in any of the patient-reported outcomes between cohorts at any time point. Six and 5 patients in the ACI and BMSC groups, respectively, underwent subsequent surgical procedures, including 1 total knee replacement in the BMSC group. None of the patients in either group developed any deep infection or tumor within the follow-up period. Conclusion: BMSC implantation used for the treatment of chondral defects of the knee appears to result in equivalent clinical outcomes to first-generation ACI at up to 10 years, with no apparent increased tumor formation risk.
Additive manufacturing of stainless steel is becoming increasingly accessible, allowing for the customisation of structure and surface characteristics; there is little guidance for the post-processing of these metals. We carried out this study to ascertain the effects of various combinations of post-processing methods on the surface of an additively manufactured stainless steel 316L lattice. We also characterized the nature of residual surface particles found after these processes via energy-dispersive X-ray spectroscopy. Finally, we measured the surface roughness of the post-processing lattices via digital microscopy. The native lattices had a predictably high surface roughness from partially molten particles. Sandblasting effectively removed this but damaged the surface, introducing a peel-off layer, as well as leaving surface residue from the glass beads used. The addition of either abrasive polishing or electropolishing removed the peel-off layer but introduced other surface deficiencies making it more susceptible to corrosion. Finally, when electropolishing was performed after the above processes, there was a significant reduction in residual surface particles. The constitution of the particulate debris as well as the lattice surface roughness following each post-processing method varied, with potential implications for clinical use. The work provides a good base for future development of post-processing methods for additively manufactured stainless steel.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.