This study suggests that applying PEEP during cuff deflation and extubation is protective against aspiration. We conclude that unless there is a contraindication, the application of PEEP should be considered when extubating patients.
Class V myosins are dimeric actin-associated motor proteins that deliver cellular cargoes to discrete cellular locations. Fission yeast possess two class V myosins, Myo51 and Myo52. Although Myo52 has been shown to have roles in vacuole distribution, cytokinesis and cell growth, Myo51 has no as yet discernible function in the vegetative life cycle. Here, we uncover distinct functions for this motor protein during mating and meiosis. Not only does Myo51 transiently localise to a foci at the site of cell fusion upon conjugation, but overexpression of the Myo51 globular tail also leads to disruption of cell fusion. Upon completion of meiotic prophase Myo51 localises to the outside of the spindle pole bodies (SPBs), where it remains until completion of meiosis II. Association of Myo51 with SPBs is not dependent upon actin or the septation initiation network (SIN); however, it is dependent on a stable microtubule cytoskeleton and the presence of the Cdc2-CyclinB complex. We observe a rapid and dynamic exchange of Myo51 at the SPB during meiosis I but not meiosis II. Finally, we show that Myo51 has an important role in regulating spore formation upon completion of meiosis.
The majority of UK critical care nurses either suction the trachea during cuff deflation and extubation of patients and/or simply ask the patient to cough. Further clinical trials are required to identify the most appropriate and safe technique for critically ill patients.
BackgroundThe PneuX System is a novel endotracheal tube and tracheal seal monitor, which has been designed to minimise the aspiration of oropharyngeal secretions. We aimed to determine the incidence of ventilator-associated pneumonia (VAP) in patients who were intubated with the PneuX System and to establish whether intermittent subglottic secretion drainage could be performed reliably and safely using the PneuX System.FindingsIn this retrospective observational study, data was collected from 53 sequential patients. Nine (17%) patients were initially intubated with the PneuX System and 44 (83%) patients underwent elective exchange to the PneuX System. There were no episodes of VAP while the PneuX System was in situ. On an intention to treat basis, the incidence VAP was 1.8%. There were no complications from, or failure of, subglottic secretion drainage during the study.ConclusionsOur study demonstrates that a low incidence of VAP is possible using the PneuX System. Our study also demonstrates that elective exchange and intermittent subglottic secretion drainage can be performed reliably and safely using the PneuX System.
BackgroundThe Lotrach endotracheal tube has a unique low-volume, low-pressure (LVLP) cuff, which has been designed to prevent pressure injury to the tracheal wall. We aimed to estimate the pressure exerted on the tracheal wall by the LVLP cuff and a conventional cuff in a bench-top, clinical and radiological study.MethodIn the bench-top study, a model trachea was intubated with the LVLP cuff and the conventional cuff. The cuff pressure was controlled using a constant pressure device. We assessed the pressure exerted on the tracheal wall by measuring the ability of the cuffs to support a column of water using a standard protocol. In the clinical study, we tested the ability of both cuffs to prevent air leak during a staged recruitment manoeuvre. In the radiological study, we recorded the degree of anatomical distortion of the trachea from both cuffs in the antero-posterior (AP) and transverse tracheal diameters. We performed statistical analysis using non-inferiority tests.ResultsIn the bench-top study, the LVLP cuff achieved a plateau at a mean height of 25.2 cmH2O (SD 0.34). In contrast, the conventional cuff failed to maintain any water above the cuff and a plateau could not be measured. In the clinical study, the mean pressure at which air leak occurred was 30.0 +/- 0.8 cmH2O (SD 3.8) using the LVLP cuff and 32.4 +/- 0.7 cmH2O (SD 3.0) using the conventional cuff. In the radiological study, the mean degree of anatomical distortion of the trachea in AP and transverse tracheal diameter was 2.9 +/- 2.2 mm (SD 2.1) and 1.8 +/- 1.4 mm (SD 1.4) using the LVLP cuff and 4.4 +/- 1.3 mm (SD 1.4) and 2.6 +/- 1.5 mm (SD 1.6) using the conventional cuff.ConclusionsThe bench-top and clinical studies both demonstrated that the LVLP cuff exerted approximately 30 cmH2O of pressure on the tracheal wall. These results are supported by our radiological study. We conclude that the LVLP cuff exerts an acceptable amount of pressure on the tracheal wall when it is operated at the recommended intracuff pressure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.