The main findings from this meta-analysis indicate that total aortic arch replacement can be performed with satisfactory mortality and morbidity. The pooled rates of mortality and permanent neurologic deficit among elective cases were surprisingly low, and these data have an even greater prominence when they are compared with outcomes of hybrid arch series. Under urgent/emergency surgery, early mortality and neurologic complications showed an about threefold higher rate. Moderate hypothermic circulatory arrest and early rewarming seem to provide proper renal protection, with an intermediate risk of prolonged intubation.
Purpose To evaluate the post-coronavirus disease-19 (COVID-19) outcome of thyroid function in patients with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-related thyrotoxicosis. Methods This was a single-center prospective study involving 29 patients (11 females, 18 males; median age 64 years, range: 43-85) with thyrotoxicosis diagnosed after hospitalization for COVID-19 and then followed-up for a median period of 90 days (range: 30-120) after hospital discharge. At follow-up, patients were evaluated for serum thyrotropin (TSH), freethyroxine (FT4), free-triiodiothyronine (FT3), TSH receptor antibodies (TRAb), thyroglobulin antibodies (TgAb), thyroperoxidase antibodies (TPOAb) and ultrasonographic thyroid structure. Results After recovery of COVID-19, serum TSH values significantly increased (P < 0.001) and FT4 values significantly decreased (P = 0.001), without significant change in serum FT3 (P = 0.572). At follow-up, 28 subjects (96.6%) became euthyroid whereas overt hypothyroidism developed in one case. At the ultrasound evaluation of thyroid gland, hypoecogenicity was found in 10 patients (34.5%) and in these cases serum TSH values tended to be higher than those without thyroid hypoecogenity (P = 0.066). All subjects resulted to be negative for TgAb, TPOAb and TRAb. Conclusion In a short-term follow-up, thyroid function spontaneously normalized in most subjects with SARS-CoV-2-related thyrotoxicosis. However, thyroid hypoecogenicity was found in a remarkable number of them and future longer-term studies are needed to clarify whether this ultrasonographic alteration may predispose to develop late-onset thyroid dysfunction.
Conversion to surgical aortic valve replacement (AVR) has been described as a complication following transcatheter aortic valve implantation. This complication occurs in up to 8% of cases and, to the best of our knowledge, preoperative data and surgical outcomes of such patients have not been properly evaluated. Mild paraprosthetic regurgitation is commonly observed after transcatheter aortic valve implantation and usually leads to a benign clinical course. Unequal distribution of valve calcifications is described as a potential mechanism. We report a case of a perioperative paraprosthetic regurgitation that underwent successful urgent surgical AVR and review the incidence and results of paraprosthetic leaks following transcatheter implantation.
Aortic valve reimplantation has been shown to be a safe procedure. However, evidences of durability in bicuspid aortic valves (BAVs) are limited in the literature. Between 2002 and 2011, 132 patients (mean age 61 ± 12 years) underwent aortic valve reimplantation. In 24 patients (18%), aortic valve was bicuspid. Mean follow-up was 50 ± 26 months (range 1-102 months) and was 99% complete. In-hospital mortality was 0.8% (1 patient). Survival at 1 and 5 years was 99 and 94%, respectively. Overall freedom from aortic valve reoperation at 1 and 5 years was 96 and 90%, respectively, without significant difference between patients with bicuspid and tricuspid aortic valve. Freedom from aortic valve regurgitation >2+/4+, excluding patients reoperated, was at 1 and 5 years of 100 and 99%, respectively. Patients with valve cusp repair showed a higher rate of aortic valve reoperation; however, only postoperative aortic regurgitation >2+/4+ was significant risk factor for redo procedure at multivariate analysis. Aortic valve reimplantation in BAV without cusp repair provides excellent mid-term results. Further observations and longer follow-up are necessary to determine if BAV sparing, even in the presence of cusps alterations, could allow satisfying durability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.