Although Tao brush has become one of the most studied and used endometrial cytological samplers, concerns remain about the adequacy of the cytological sample compared with definitive histology. We aimed to assess accuracy of cytological examination from Tao brush sampling in diagnosing endometrial premalignancy and malignancy through a systematic review and meta-analysis. Seven electronic databases were searched from January 2000 to July 2021 for all studies which allowed assessment of accuracy of Tao brush in diagnosing endometrial premalignancy and malignancy. We calculated sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR−), diagnostic odds ratio (DOR) and area under the curve (AUC) on summary receiver operating characteristic (SROC) curve. Five studies with 774 patients were included. In diagnosing endometrial premalignancy and malignancy, cytological examination from Tao brush endometrial sampling showed pooled sensitivity of 0.95 (95% CI, 0.90-0.98), specificity of 0.92 (95% CI, 0.90-0.94), LR+ of 12.73 (95% CI, 3.94-41.18), LR− of 0.09 (95% CI, 0.05-0.18), DOR of 184.84 (95% CI, 24.37-1401.79), AUC of 0.9757 (standard error: 0.013). In conclusion, cytological examination from Tao brush seems to have a high diagnostic accuracy and might be proposed as both screening and diagnostic tool. However, further studies are necessary to confirm these findings.
Background and Objectives: To assess the use of near infrared radiation imaging after injection of indocyanine green (NIR–ICG) during laparoscopic treatment of benign gynecologic conditions. Materials and Methods: A systematic review of the literature was performed searching 7 electronic databases from their inception to March 2022 for all studies which assessed the use of NIR–ICG during laparoscopic treatment of benign gynecological conditions. Results: 16 studies (1 randomized within subject clinical trial and 15 observational studies) with 416 women were included. Thirteen studies assessed patients with endometriosis, and 3 studies assessed non-endometriosis patients. In endometriosis patients, NIR–ICG use appeared to be a safe tool for improving the visualization of endometriotic lesions and ureters, the surgical decision-making process with the assessment of ureteral perfusion after conservative surgery and the intraoperative assessment of bowel perfusion during recto-sigmoid endometriosis nodule surgery. In non-endometriosis patients, NIR–ICG use appeared to be a safe tool for evaluating vascular perfusion of the vaginal cuff during total laparoscopic hysterectomy (TLH) and robotic-assisted total laparoscopic hysterectomy (RATLH), and intraoperative assessment of ovarian perfusion in adnexal torsion. Conclusions: NIR–ICG appeared to be a useful tool for enhancing laparoscopic treatment of some benign gynecologic conditions and for moving from minimally invasive surgery to minimalized surgery. In particular, it might improve treatment of endometriosis (with particular regard to deep infiltrating endometriosis), benign diseases requiring TLH and RATLH and adnexal torsion. However, although preliminary findings appear promising, further investigation with well-designed larger studies is needed.
Robotic surgery has been approved as an alternative to laparoscopy to improve surgical outcomes. There is neither a consensus nor a systematic assessment of the literature about the superiority of the robotic approach over the laparoscopic one for sentinel lymph node (SLN) biopsy in endometrial carcinoma (EC) women. Therefore, a systematic review and meta-analysis was performed to compare the laparoscopic and robotic approaches for SLN biopsy in EC patients. Five electronic databases were queried from their inception to May 2022 for peer-reviewed studies, comparing such approaches in SLN biopsy in EC patients. The rate of detected SLN, dissected SLN, intraoperative and postoperative complications, conversion to laparotomy, number of dissected SLN, and SLN identification and dissection time were compared between the laparoscopic and robotic approaches for SLN biopsy in EC patients. Odds ratios with 95% confidence intervals were calculated when possible. Two studies with 660 EC women (364 who had undergone laparoscopy, and 296 who had robotic surgery) were included. No assessed outcome showed significant differences between the two approaches. In conclusion, the laparoscopic and robotic approaches for SLN biopsy in EC patients appeared to not differ, in terms of SLN detection, intraoperative and postoperative complications, conversion to laparotomy, number of dissected SLN, and SLN identification and dissection time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.