Background This research aims to increase our knowledge of amyloidoses. These disorders cause incorrect protein folding, affecting protein functionality (on structure). Fibrillar deposits are the basis of some wellknown diseases, such as Alzheimer, Creutzfeldt–Jakob diseases and type II diabetes. For many of these amyloid proteins, the relative precursors are known. Discovering new protein precursors involved in forming amyloid fibril deposits would improve understanding the pathological processes of amyloidoses. Results A new classifier, called ENTAIL, was developed using over than 4000 molecular descriptors. ENTAIL was based on the Naive Bayes Classifier with Unbounded Support and Gaussian Kernel Type, with an accuracy on the test set of 81.80%, SN of 100%, SP of 63.63% and an MCC of 0.683 on a balanced dataset. Conclusions The analysis carried out has demonstrated how, despite the various configurations of the tests, performances are superior in terms of performance on a balanced dataset.
Background SNARE proteins play an important role in different biological functions. This study aims to investigate the contribution of a new class of molecular descriptors (called SNARER) related to the chemical-physical properties of proteins in order to evaluate the performance of binary classifiers for SNARE proteins. Results We constructed a SNARE proteins balanced dataset, D128, and an unbalanced one, DUNI, on which we tested and compared the performance of the new descriptors presented here in combination with the feature sets (GAAC, CTDT, CKSAAP and 188D) already present in the literature. The machine learning algorithms used were Random Forest, k-Nearest Neighbors and AdaBoost and oversampling and subsampling techniques were applied to the unbalanced dataset. The addition of the SNARER descriptors increases the precision for all considered ML algorithms. In particular, on the unbalanced DUNI dataset the accuracy increases in parallel with the increase in sensitivity while on the balanced dataset D128 the accuracy increases compared to the counterpart without the addition of SNARER descriptors, with a strong improvement in specificity. Our best result is the combination of our descriptors SNARER with CKSAAP feature on the dataset D128 with 92.3% of accuracy, 90.1% for sensitivity and 95% for specificity with the RF algorithm. Conclusions The performed analysis has shown how the introduction of molecular descriptors linked to the chemical-physical and structural characteristics of the proteins can improve the classification performance. Additionally, it was pointed out that performance can change based on using a balanced or unbalanced dataset. The balanced nature of training can significantly improve forecast accuracy.
Background: Melanoma is one of the deadliest tumors in the world. Early detection is critical for first-line therapy in this tumor pathology and it remains challenging due to the need for histological analysis to ensure correctness in diagnosis. Therefore, multiple computer-aided diagnosis (CAD) systems working on melanoma images were proposed to mitigate the need of a biopsy. However, although the high global accuracy is declared in literature results, the CAD systems for the health fields must focus on the lowest false negative rate (FNR) possible to qualify as a diagnosis support system. The final goal must be to avoid classification type 2 errors to prevent life-threatening situations. Another goal could be to create an easy-to-use system for both physicians and patients. Results: To achieve the minimization of type 2 error, we performed a wide exploratory analysis of the principal convolutional neural network (CNN) architectures published for the multiple image classification problem; we adapted these networks to the melanoma clinical image binary classification problem (MCIBCP). We collected and analyzed performance data to identify the best CNN architecture, in terms of FNR, usable for solving the MCIBCP problem. Then, to provide a starting point for an easy-to-use CAD system, we used a clinical image dataset (MED-NODE) because clinical images are easier to access: they can be taken by a smartphone or other hand-size devices. Despite the lower resolution than dermoscopic images, the results in the literature would suggest that it would be possible to achieve high classification performance by using clinical images. In this work, we used MED-NODE, which consists of 170 clinical images (70 images of melanoma and 100 images of naevi). We optimized the following CNNs for the MCIBCP problem: Alexnet, DenseNet, GoogleNet Inception V3, GoogleNet, MobileNet, ShuffleNet, SqueezeNet, and VGG16. Conclusions: The results suggest that a CNN built on the VGG or AlexNet structure can ensure the lowest FNR (0.07) and (0.13), respectively. In both cases, discrete global performance is ensured. 73% (accuracy), 82% (sensitivity) and 59% (specificity) for VGG; 89% (accuracy), 87% (sensitivity) and 90% (specificity) for AlexNet.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.