In MRI, motion correction for fetal body poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume (SVR) reconstruction methods provide efficient solution for the fetal brain that undergoes only rigid transformation or 4D fetal heart with rigid states correlated to cardiac phases. However, for fetal body reconstruction, rigid registration cannot resolve the issue of misregistrations due to deformable motion. This results in propagation of registration error to the reconstructed volume and subsequent degradation of features. We propose a novel approach for non-rigid motion correction in 3D volumes based on an extension of the classical SVR method with hierarchical deformable registration scheme and structure-based outlier rejection. Deformable SVR (DSVR) method allows high resolution reconstruction of the fetal trunk and the robust scheme for structure-based rejection of misregistered slices minimises the impact of registration error. The method performance is evaluated by comparison to the SVR and patch-to-volume registration methods for reconstruction of fetal trunk on a series of fetal MRI datasets from 28-30 weeks gestational age (GA) range with varying degree of motion corruption. An additional phantom study with simulated nonrigid motion is used for the assessment of consistency of DSVR reconstructed volumes.
The Developing Human Connectome Project has created a large open science resource which provides researchers with data for investigating typical and atypical brain development across the perinatal period. It has collected 1228 multimodal magnetic resonance imaging (MRI) brain datasets from 1173 fetal and/or neonatal participants, together with collateral demographic, clinical, family, neurocognitive and genomic data from 1173 participants, together with collateral demographic, clinical, family, neurocognitive and genomic data. All subjects were studied in utero and/or soon after birth on a single MRI scanner using specially developed scanning sequences which included novel motion-tolerant imaging methods. Imaging data are complemented by rich demographic, clinical, neurodevelopmental, and genomic information. The project is now releasing a large set of neonatal data; fetal data will be described and released separately. This release includes scans from 783 infants of whom: 583 were healthy infants born at term; as well as preterm infants; and infants at high risk of atypical neurocognitive development. Many infants were imaged more than once to provide longitudinal data, and the total number of datasets being released is 887. We now describe the dHCP image acquisition and processing protocols, summarize the available imaging and collateral data, and provide information on how the data can be accessed.
This illustrative review depicts the evolving role of magnetic resonance imaging (MRI) in the diagnosis and prognostication of anomalies of the fetal body (here including head and neck, thorax, abdomen and spine). A review of the current literature describing the state-of-theart in antenatal imaging for diagnosis and prognostication of congenital anomalies is coupled with illustrative cases in true radiological planes with viewable 3D video models that demonstrate the potential of post-acquisition reconstruction protocols.Within, we will discuss benefits and limitations of fetal MRI across the breadth of conditions included: from anomaly detection, classification and prognostication as well as defining the role of imaging in the decision to proceed to prenatal intervention. Reference will also be made to the current capabilities of ultrasound and we will explore potential ways in which the two may perform complimentary roles in the future of prenatal imaging.
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Prenatal detection of congenital heart disease facilitates the opportunity for potentially life-saving care immediately after the baby is born. Echocardiography is routinely used for screening of morphological malformations, but functional measurements of blood flow are scarcely used in fetal echocardiography due to technical assumptions and issues of reliability. Magnetic resonance imaging (MRI) is readily used for quantification of abnormal blood flow in adult hearts, however, existing in utero approaches are compromised by spontaneous fetal motion. Here, we present and validate a novel method of MRI velocity-encoding combined with a motion-robust reconstruction framework for four-dimensional visualization and quantification of blood flow in the human fetal heart and major vessels. We demonstrate simultaneous 4D visualization of the anatomy and circulation, which we use to quantify flow rates through various major vessels. The framework introduced here could enable new clinical opportunities for assessment of the fetal cardiovascular system in both health and disease.
In multi-channel (MC) registration, fusion of structural and diffusion brain MRI provides information on both cortex and white matter (WM) structures thus decreasing the uncertainty of deformation fields. However, the existing solutions employ only diffusion tensor imaging (DTI) derived metrics which are limited by inconsistencies in fiber-crossing regions. In this work, we extend the pipeline for registration of multi-shell high angular resolution diffusion imaging (HARDI) [15] with a novel similarity metric based on angular correlation and an option for multi-channel registration that allows incorporation of structural MRI. The contributions of channels to the displacement field are weighted with spatially varying certainty maps. The implementation is based on MRtrix3 (MRtrix3: https://www.mrtrix.org) toolbox. The approach is quantitatively evaluated on intra-patient longitudinal registration of diffusion MRI datasets of 20 preterm neonates with 7-11 weeks gap between the scans. In addition, we present an example of an MC template generated using the proposed method.
This study presents a comparison of quantitative MRI methods based on an efficiency metric that quantifies their intrinsic ability to extract information about tissue parameters. Under a regime of unbiased parameter estimates, an intrinsic efficiency metric was derived for fully-sampled experiments which can be used to both optimize and compare sequences. Here we optimize and compare several steady-state and transient gradient-echo based qMRI methods, such as magnetic resonance fingerprinting (MRF), for joint and mapping. The impact of undersampling was also evaluated, assuming incoherent aliasing that is treated as noise by parameter estimation. In vivo validation of the efficiency metric was also performed. Transient methods such as MRF can be up to 3.5 times more efficient than steady-state methods, when spatial undersampling is ignored. If incoherent aliasing is treated as noise during least-squares parameter estimation, the efficiency is reduced in proportion to the SNR of the data, with reduction factors of 5 often seen for practical SNR levels. In vivo validation showed a very good agreement between the theoretical and experimentally predicted efficiency. This work presents and validates an efficiency metric to optimize and compare the performance of qMRI methods. Transient methods were found to be intrinsically more efficient than steady-state methods, however the effect of spatial undersampling can significantly erode this advantage.
Down syndrome (DS) occurs with triplication of human chromosome 21 and is associated with deviations in cortical development evidenced by simplified gyral appearance and reduced cortical surface area. Radial glia are neuronal and glial progenitors that also create a scaffolding structure essential for migrating neurons to reach cortical targets and therefore play a critical role in cortical development. The aim of this study was to characterise radial glial expression pattern and morphology in the frontal lobe of the developing human fetal brain with DS and age-matched controls. Secondly, we investigated whether microstructural information from in vivo magnetic resonance imaging (MRI) could reflect histological findings from human brain tissue samples. Immunohistochemistry was performed on paraffin-embedded human post-mortem brain tissue from nine fetuses and neonates with DS (15-39 gestational weeks (GW)) and nine euploid age-matched brains (18-39 GW). Radial glia markers CRYAB, HOPX, SOX2, GFAP and Vimentin were assessed in the Ventricular Zone, Subventricular Zone and Intermediate Zone. In vivo diffusion MRI was used to assess microstructure in these regions in one DS (21 GW) and one control (22 GW) fetal brain. We found a significant reduction in radial glial progenitor SOX2 and subtle deviations in radial glia expression (GFAP and Vimentin) prior to 24 GW in DS. In vivo, fetal MRI demonstrates underlying radial projections consistent with immunohistopathology. Radial glial alterations may contribute to the subsequent simplified gyral patterns and decreased cortical volumes observed in the DS brain. Recent advances in fetal MRI acquisition and analysis could provide non-invasive imaging-based biomarkers of early developmental deviations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.