Triple-site CRT is associated with more pronounced functional improvement than standard resynchronization. This form of pacing is equally safe and feasible as the conventional CRT. However, triple-site procedure is more time-consuming, associated with higher radiation exposure and the need to use additional techniques. Triple-site resynchronization is associated with less favorable electrical lead characteristics.
These preliminary data suggest that CRT seems to be an effective method of reducing the outflow tract gradient and improving the functional status of symptomatic HOCM patients requiring ICD implantation. Our findings need to be confirmed by more extensive studies.
TRUST CRT is a randomized, clinical trial in CRT candidates to evaluate the effectiveness of triple-site pacing versus standard resynchronization in patients with HF.
Aims
The number of patients with heart failure (HF) and implantable cardiac electronic devices has been growing steadily. Remote monitoring care (RC) of cardiac implantable electronic devices can facilitate patient-healthcare clinical interactions and prompt preventive activities to improve HF outcomes. However, studies that have investigated the efficacy of remote monitoring have shown mixed findings, with better results for the system including daily verification of transmission. The purpose of the RESULT study was to analyse the impact of remote monitoring on clinical outcomes in HF patients with implantable cardioverter-defibrillator [ICD/cardiac resynchronization therapy-defibrillator (CRT-D)] in real-life conditions.
Methods and results
The RESULT is a prospective, single-centre, randomized trial. Patients with HF and de novo ICD or CRT-D implantation were randomized to undergo RC vs. in-office follow-ups (SC, standard care). The primary endpoint was a composite of all-cause death and hospitalization due to cardiovascular reasons within 12 months after randomization. We randomly assigned 600 eligible patients (299 in RC vs. 301 in SC). Baseline clinical and echocardiographic characteristics were well-balanced and similar in both arms. The incidence of the primary endpoint differed significantly between RC and SC and involved 39.5% and 48.5% of patients, respectively, (P = 0.048) within the 12-month follow-up. The rate of all-cause mortality was similar between the studied groups (6% vs. 6%, P = 0.9), whereas hospitalization rate due to cardiovascular reasons was higher in SC (37.1% vs. 45.5%, P = 0.045).
Conclusion
Remote monitoring of HF patients with implanted ICD or CRT-D significantly reduced the primary endpoint rate, mostly as a result of a lower hospitalization rate in the RC arm (ClinicalTrials.gov Identifier: NCT02409225).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.