Study findings contribute to understand the role of oximetry in the diagnosis of OSA in obese patients. Our results were observed using full PSG and a simplified home method. The correlation between these indicators could improve our clinical interpretation of OSA severity among obese patients when abbreviated tests are used.
STOP-BANG shows different discrimination power for AHI >5 and ≥30/h using RP. Five components in any combination have acceptable diagnostic S to identify patients with severe OSA. STOP-BANG performed best to identify AHI ≥30/h.
Background
Iota-Carrageenan (I-C) is a sulfate polysaccharide synthesized by red algae, with demonstrated antiviral activity and clinical efficacy as nasal spray in the treatment of common cold. In vitro, I-C inhibits SARS-CoV-2 infection in cell culture.
Research Question
Can a nasal spray with Iota-Carrageenan be useful in the prophylaxis of COVID-19 in health care workers managing patients with COVID-19 disease?
Study Design and Methods
This is a pilot pragmatic multicenter, randomized, double-blind, placebo-controlled study assessing the use of a nasal spray containing I-C in the prophylaxis of COVID-19 in hospital personnel dedicated to care of COVID-19 patients. Clinically healthy physicians, nurses, kinesiologists and other health care providers managing patients hospitalized for COVID-19 were assigned in a 1:1 ratio to receive four daily doses of I-C spray or placebo for 21 days. The primary end point was clinical COVID-19, as confirmed by reverse transcriptase polymerase chain reaction testing, over a period of 21 days. The trial is registered at ClinicalTrials.gov (NCT04521322).
Results
A total of 394 individuals were randomly assigned to receive I-C or placebo. Both treatment groups had similar baseline characteristics. The incidence of COVID-19 differs significantly between subjects receiving the nasal spray with I-C (2 of 196 [1.0%]) and those receiving placebo (10 of 198 [5.0%]). Relative risk reduction: 79.8% (95% CI 5.3 to 95.4; p=0.03). Absolute risk reduction: 4% (95% CI 0.6 to 7.4).
Interpretation
In this pilot study a nasal spray with I-C showed significant efficacy in preventing COVID-19 in health care workers managing patients with COVID-19 disease.
Clinical Trials Registration
NCT04521322.
In hypertension (HT) patients, RP revealed a high prevalence of OSA associated with carotid artery disease, high PWV, and increased cardiovascular risk.
IntroductionObstructive sleep apnea syndrome (OSA) is diagnosed through polysomnography (PSG) or respiratory polygraphy (RP). Self-administered home-based RP using devices with data transmission could facilitate diagnosis in distant populations. The purpose of this work was to describe a telemedicine initiative using RP in four satellite outpatient care clinics (OCC) of Buenos Aires Hospital Británico Central (HBC).Materials and methodsOCC technicians were trained both in the use of RP. Raw signals were sent to HBC via intranet software for scoring and final report.ResultsDuring a 24-month 499 RP were performed in 499 patients: 303 men (60.7%) with the following characteristics (mean and standard deviation): valid time for manual analysis: 392.8 min (±100.1), AHI: 17.05 (±16.49 and percentile 25–75 [Pt]: 5–23) ev/hour, ODI (criterion 3%): 18.05 (±16.48 and Pt 25–75: 6–25) ev/hour, and time below 90% (T<90): 17.9% (±23.4 and Pt 25–75: 1–23). The distribution of diagnoses (absolute value and percentage) was: normal (66/13%), snoring (70/14%), mild (167/33.5%), moderate (110/22%), and severe (86/17.2%). Continuous positive airway pressure (CPAP) was indicated for 191 patients (38.6%). Twenty recordings (4%) were considered invalid and the RP had to be repeated.PSG at HBC was indicated in 60 (12.1%) cases (mild OSA or normal AHI with high ESS or cardiovascular disease).ConclusionsPhysicians were able to diagnosis OSA by doing portable respiratory polygraphy at distance. The remote diagnosis strategy presented short delays, safe data transmission, and low rate of missing data.
ObjectiveTo establish the prevalence of positional (PP) OSA patients using
self-administered home-based respiratory polygraphy (RP).Materials and Methods52 month retrospective study based on RP records.Results200 PR records: 70.5% men 29.5% women. 76% were diagnosed with OSA and 54.6%
with PP OSA. There were no significant differences in Epworth Sleepiness
Scale, apnea hypopnea index and oxygen desaturation index. PP OSA patients
were younger, had a lower BMI (30.3±0.9 vs. 35.3±1.2)
(p<0.0001), and the time they spent with oxygen
saturation <90% (T<90) was lower (8.8 vs. 28.7±6.7,
p=0.0038). The PP OSA group spent 43% of total
recording time in the supine position.ConclusionsThe prevalence of PP OSA patients studied with RP is similar to the one
described by sleep laboratories. They have lower BMI, present mostly mild
OSA with less desaturation, and are less likely to receive CPAP therapy.
Objectives. To compare interfaces performance during home-based automatic titration (APAP). Methods. Retrospective study based on APAP titration from Obstructive Sleep Apnea Syndrome (OSA) patients. Results. 707 patients, 513 men (70.6%), were titrated. Masks were 104 pillows (14.7%), group I (GI); 532 nasal (75.2%), group II (GII); and 71 oronasal masks (10%), group III (GIII). We found differences in effective pressure to the device (P90/P95) (GI: 7.13±1.9 vs. GII: 8.3±2.1 vs. GIII: 9.3±2.6 cmH2O, p <0.001) but not in final pressure titrated manually (GI: 7.9±1.4 vs. GII: 8.6±1.6 vs. GIII: 9.2±1.9 cm of H2O, p >0.5), where lower residual AHI for pillows was p <0.001 and leaks for nasal were p <0.001. No differences were found in compliance (hours) (GI: 6.3±1.2 vs. GII: 6.2±1.1 vs. GIII: 6.1±1.0, p <0.4). Conclusion. During auto-adjusting titration by CPAP-naïve patients, nasal masks had lower leak rates and nasal pillows presented a similar performance.
BackgroundThe prevalence of obstructive sleep apnea (OSA) increases with age. However, older adults have limited perception of the symptoms related with poor sleep quality. ObjectivesTo know the frequency and characteristics of age-related OSA in a large population with clinical suspicion of sleep apnea. MethodsWe conducted a retrospective study. OSA was studied by respiratory polygraphy (RP). Patients were grouped by age (G): GI was between 18-45; GII: 46-65 and GIII > 65 years old. Other demographic characteristics, symptoms and RP indicators were compared. Epworth Sleep Scale (ESS) was used to analyze symptoms. ResultsWe included 2491 patients with sleep apnea symptoms. OSA frequency (AHI > 15) in each group was 33.2 % in GI; 45.8 in GII and 50.3 in GIII (p < 0.001). Despite the significant increase in OSA severity, GIII group reported fewer symptoms (ESS: 6.0; p < 0.001). Multivariate adjusted analysis showed that the odds ratio of having OSA is three times as high at age > 65 (OR: 3.32 (2.29 - 4.88) p < 0.001). ConclusionsAs in previous reports, OSA prevalence in our population was higher among the elderly. The early identification of this syndrome in a population with poor perception of symptoms would aid to improve patient management.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.