It is important to know the spectrum of the microbial aetiology of prosthetic joint infections (PJIs) to guide empiric treatment and establish antimicrobial prophylaxis in joint replacements. There are no available data based on large contemporary patient cohorts. We sought to characterize the causative pathogens of PJIs and to evaluate trends in the microbial aetiology. We hypothesized that the frequency of antimicrobial-resistant organisms in PJIs has increased in the recent years. We performed a cohort study in 19 hospitals in Spain, from 2003 to 2012. For each 2-year period (2003-2004 to 2011-2012), the incidence of microorganisms causing PJIs and multidrug-resistant bacteria was assessed. Temporal trends over the study period were evaluated. We included 2524 consecutive adult patients with a diagnosis of PJI. A microbiological diagnosis was obtained for 2288 cases (90.6%). Staphylococci were the most common cause of infection (1492, 65.2%). However, a statistically significant rising linear trend was observed for the proportion of infections caused by Gram-negative bacilli, mainly due to the increase in the last 2-year period (25% in 2003-2004, 33.3% in 2011-2012; p 0.024 for trend). No particular species contributed disproportionally to this overall increase. The percentage of multidrug-resistant bacteria PJIs increased from 9.3% in 2003-2004 to 15.8% in 2011-2012 (p 0.008), mainly because of the significant rise in multidrug-resistant Gram-negative bacilli (from 5.3% in 2003-2004 to 8.2% in 2011-2012; p 0.032). The observed trends have important implications for the management of PJIs and prophylaxis in joint replacements.
Per the American Association of Orthopaedic Surgeons (AAOS) guidelines or the Musculoskeletal Infection Society (MSIS), 23% of the patients in the present study with PJI would never have been identified. Blood inflammatory markers such as the CRP level and ESR may not be accurate as diagnostic tools in PJI, particularly to identify low-grade and chronic PJI.
dSonication improved the diagnosis of orthopedic implant-associated infections (OIAI). We investigated the diagnostic performance of sonication fluid inoculated into blood culture bottles in comparison with that of intraoperative tissue and sonication fluid cultures. Consecutive patients with removed orthopedic hardware were prospectively included and classified as having OIAI or aseptic failure (AF) according to standardized criteria. The diagnostic procedure included the collection of five intraoperative tissue cultures and sonication of the removed device, followed by conventional culture of the sonication fluid. Cultures were incubated for 7 days (aerobic) or 14 days (anaerobic). In addition, 10 ml of sonication fluid was inoculated into each aerobic and anaerobic BacT/Alert FAN blood culture bottle and incubated in the automated blood culture system for 5 days. Of 75 included patients, 39 had OIAI and 36 AF. The sensitivity of sonication fluid inoculated into blood culture bottles (100%) was higher than that of conventional sonication fluid (87%; P ؍ 0.05) or intraoperative tissue cultures (59%; P < 0.01). Previous antibiotic therapy reduced the culture sensitivity of conventional sonication fluid to 77% and that of intraoperative tissue to 55%, while it remained 100% for blood culture-inoculated sonication fluid. The time to positivity was shorter in blood culture-inoculated sonication fluid, with detection of 72% of microorganisms after 1 day of incubation, than for intraoperative tissue and conventional sonication fluid cultures, with detection of 18% and 28% of microorganisms, respectively. In conclusion, compared to conventional sonication fluid and intraoperative tissue cultures, sonication fluid inoculated into blood culture bottles improved the diagnosis of OIAI and considerably reduced the time to culture positivity.T he pathogenesis of orthopedic implant-associated infections (OIAI) is related to biofilms, rendering these infections difficult to diagnose. Microorganisms in biofilms are embedded in a hydrated extracellular matrix, adhered to the surface, and transformed in a less metabolically active state than microorganisms in biofilms (1). An accurate diagnosis of OIAI is crucial for treatment success. A combination of various preoperative and intraoperative methods is usually needed for microbiological diagnosis of OIAI (2, 3). However, current diagnostic methods have limited sensitivity, with 10 to 30% false-negative results, and/or lack specificity (2).Research and development of new diagnostic methods aim to improve the diagnostic accuracy and speed of microbial detection in foreign-body infections. Sonication of explanted implants, designed to remove attached biofilms, significantly improved the culture sensitivity compared to that of conventional microbiological methods using synovial fluid or intraoperative tissue samples. Sonication was evaluated in infections involving prosthetic joints, fracture fixation devices, vascular grafts, neurosurgical shunts, breast implants, and cardiac dev...
The purpose of this study was to compare the diagnostic accuracy for the detection of infection between the culture of fluid obtained by sonication (SFC) and the culture of peri-implant tissues (PITC) in patients with early and delayed implant failure, and those with unsuspected and suspected septic failure. It was hypothesised that SFC increases the diagnostic accuracy for infection in delayed, but not early, implant failure, and in unsuspected septic failure. The diagnostic accuracy for infection of all consecutive implants (hardware or prostheses) that were removed for failure was compared between SFC and PITC. This prospective study included 317 patients with a mean age of 62.7 years (9 to 97). The sensitivity for detection of infection using SFC was higher than using PITC in an overall comparison (89.9% versus 67%, respectively; p < 0.001), in unsuspected septic failure (100% versus 48.5%, respectively; p < 0.001), and in delayed implant failure (88% versus 58%, respectively; p < 0.001). PITC sensitivity dropped significantly in unsuspected compared with suspected septic failure (p = 0.007), and in delayed compared with early failure (p = 0.013). There were no differences in specificity. Sonication is mainly recommended when there is implant failure with no clear signs of infection and in patients with delayed implant failure. In early failure, SFC is not superior to PITC for the diagnosis of infection and, therefore, is not recommended as a routine diagnostic test in these patients.
Patients with infected arthroplasties are normally treated with a two-stage exchange procedure using polymethylmethacrylate bone cement spacers impregnated with antibiotics. However, spacers may act as a foreign body to which micro-organisms may adhere and grow. In this study it was hypothesised that subclinical infection may be diagnosed with sonication of the surface biofilm of the spacer. The aims were to assess the presence of subclinical infection through sonication of the spacer at the time of a second-stage procedure, and to determine the relationship between subclinical infection and the clinical outcome. Of 55 patients studied, 11 (20%) were diagnosed with subclinical infection. At a mean follow-up of 12 months (interquartile range 6 to 18), clinical failure was found in 18 (32.7%) patients. Of the patients previously diagnosed with subclinical infection, 63% (7 of 11) had failed compared with 25% (11 of 44) of those without subclinical infection (odds ratio 5.25, 95% confidence interval 1.29 to 21.4, p = 0.021). Sonication of the biofilm of the surface of the spacer is useful in order to exclude subclinical infection and therefore contributes to improving the outcome after two-stage procedures.
Background The outcome of revision surgery depends on accurate determination of the cause of prosthesis failure because treatment differs profoundly among aseptic loosening, mechanical failure, and prosthetic joint infections (PJI). Questions/purposes We sought to determine (1) the predictive role of the interval from primary to revision surgery in determining the reason for prosthesis failure of a hip, knee, shoulder, or elbow arthroplasty, and (2) whether positive cultures during revision surgery for aseptic loosening were associated with shorter event-free survival of the prosthesis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.