BackgroundExtracorporeal membrane oxygenation (ECMO) have become more frequently used in daily ICU practice, heparin-induced thrombocytopenia (HIT) is a rare but life-threatening complication while on extracorporeal membrane oxygenation (ECMO). HIT confirmation directly impacts on anticoagulant strategy requiring no delay unfractionated heparin discontinuation to be replaced by alternative systemic anticoagulant treatment.Case presentationWe report two clinical cases of HIT occurring during ECMO in various settings with subsequent recovery with argatroban and provide literature review to help physicians treat HIT during ECMO in clinical daily practice.ConclusionsHIT during ECMO is uncommon, and despite the absence of recommendation, argatroban seems to be an appropriate and safe therapeutic option. Finally, there are not enough arguments favouring routine circuit change in the event of HIT during ECMO
BackgroundTranscatheter aortic-valve implantation (TAVI) is a new therapeutic choice for treating aortic stenosis in patients considered high risk for surgery. This blooming therapeutic technique still requires evaluation of medium and long term outcome.MethodWe hereby report our results of the first 150 consecutive patients to receive TAVI implants in our population recruited from July 2009 to March 2013 in a retrospective and monocentric study. We analyzed long term morbidity and mortality criteria. We compared the apical and femoral approach results and researched predictors of cardiac mortality.ResultsThe mean monitoring period was 387.62 days, mean Euroscore was 21.8, and mean Society of Thoracic Surgeons (STS) risk score was 9.2. The success rate for the procedure was 94.6 %. A total of 39 patients died. The mortality rates at the immediate perioperative point, 30 days, 1 year, and 2 years, were 4 %, 11.3 %, 22.7 %, and 26 %, respectively. As regards complications, there were 10 hemodynamic complications (6.6 %) and 20 vascular (13.3 %), 11 cardiac tamponades (7.4 %), eight mechanical (5.3 %), ten major hemorrhagic (6.7 %), 14 pulmonary (9.3 %), and 18 infectious complications (12 %). When comparing the rates of reported complications in terms of different approaches, we observed significantly more hemodynamic complications in the apical group (p = 0.049). Pulmonary complications were also significantly more common in cases of apical approach (p = 0.029). The majority of the patients reported clear functional improvement throughout their follow-up.ConclusionThe results of the first 150 patients to receive the implant at the Nancy University Teaching Hospital (CHU Nancy) were consistent with findings in the literature. TAVI proved a credible and effective alternative to surgical valve replacement for patients at high risk during surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.