Valsartan is known to be excreted largely as unchanged compound and is minimally metabolized in man. Although the only notable metabolite is 4-hydroxyvaleryl metabolite (4-OH valsartan), the responsible enzyme has not been clarified at present. The current in vitro studies were conducted to identify the cytochrome P450 (CYP) enzymes involved in the formation of 4-OH valsartan. Valsartan was metabolized to 4-OH valsartan by human liver microsomes and the Eadie-Hofstee plots were linear. The apparent Km and Vmax values for the formation of 4-OH valsartan were 41.9-55.8 microM and 27.2-216.9 pmol min(-1) mg(-1) protein, respectively. There was good correlation between the formation rates of 4-OH valsartan and diclofenac 4'-hydroxylase activities (representative CYP2C9 activity) of 11 individual microsomes (r = 0.889). No good correlation was observed between any of the other CYP enzyme marker activities (CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP2E1, CYP3A4 and CYP4A). Among the recombinant CYP enzymes examined (CYPs 1A2, 2A6, 2B6, 2C8, 2C9, 2C19, 2D6, 2E1, 3A4, 3A5 and 4A11), CYP2C9 notably catalysed 4-hydroxylation of valsartan. For the specific CYP inhibitors or substrates examined (furafylline, diclofenac, S(+)-mephenytoin, quinidine and troleandomycin), only diclofenac inhibited the formation of 4-OH valsartan. These results showed that CYP2C9 is the only form responsible for 4-hydroxylation of valsartan in human liver microsomes. Although CYP2C9 is involved in valsartan metabolism, CYP-mediated drug-drug interaction between valsartan and other co-administered drugs would be negligible.
We have developed a sensitive and specific liquid chromatography/mass spectrometry (LC/MS) method for the simultaneous determination of cyclosporine A (CsA) and its three main metabolites (AM1, AM4N and AM9) in human blood. Following protein precipitation, supernatant was directly injected into the LC/MS system. Chromatographic separation was accomplished on a Symmetry C8 (4.6 x 75 mm, 3.5 microm) column with a linear gradient elution prior to detection by atmospheric pressure chemical ionization (APCI) MS using selected ion monitoring (SIM) in positive mode. This method can be applied to single mass equipment. The analytical range for each analyte was set at 1-2500 ng/mL using 100 microL of blood sample. The analytical method was fully validated according to FDA guidance. Intra-day mean accuracy and precision were 95.2-113.5% and 0.9-8.9%, respectively. Inter-day mean accuracy and precision were 95.8-107.0% and 1.5-10.7%, respectively. In blood all analytes were stable during three freeze/thaw cycles, for 24 h at room temperature and for 12 months at or below -15 degrees C. Stability was also confirmed in processed samples for 24 h at 10 degrees C and for 6 months at 4 degrees C in methanol. In addition, we confirmed the method could avoid matrix effects from transplant subjects' samples. This LC/MS technique provided an excellent method for simultaneous quantitative determination of CsA and its three metabolites for evaluation of their pharmacokinetic profiles.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.