This paper describes a pragmatic approach that can be applied in assessing powder blend and unit dosage uniformity of solid dose products at Process Design, Process Performance Qualification, and Continued/Ongoing Process Verification stages of the Process Validation lifecycle. The statistically based sampling, testing, and assessment plan was developed due to the withdrawal of the FDA draft guidance for industry "Powder Blends and Finished Dosage Units-Stratified In-Process Dosage Unit Sampling and Assessment." This paper compares the proposed Grouped Area Variance Estimate (GAVE) method with an alternate approach outlining the practicality and statistical rationalization using traditional sampling and analytical methods. The approach is designed to fit solid dose processes assuring high statistical confidence in both powder blend uniformity and dosage unit uniformity during all three stages of the lifecycle complying with ASTM standards as recommended by the US FDA.
Abstract. This paper introduces an innovative statistical approach towards understanding how variation impacts the acceptance criteria of quality attributes. Because of more complex stage-wise acceptance criteria, traditional process capability measures are inadequate for general application in the pharmaceutical industry. The probability of acceptance concept provides a clear measure, derived from specific acceptance criteria for each quality attribute. In line with the 2011 FDA Guidance, this approach systematically evaluates data and scientifically establishes evidence that a process is capable of consistently delivering quality product. The probability of acceptance provides a direct and readily understandable indication of product risk. As with traditional capability indices, the acceptance probability approach assumes that underlying data distributions are normal. The computational solutions for dosage uniformity and dissolution acceptance criteria are readily applicable. For dosage uniformity, the expected AV range may be determined using the s lo and s hi values along with the worst case estimates of the mean. This approach permits a risk-based assessment of future batch performance of the critical quality attributes. The concept is also readily applicable to sterile/non sterile liquid dose products. Quality attributes such as deliverable volume and assay per spray have stage-wise acceptance that can be converted into an acceptance probability. Accepted statistical guidelines indicate processes with C pk >1.33 as performing well within statistical control and those with C pk <1.0 as Bincapable^(1). A C pk >1.33 is associated with a centered process that will statistically produce less than 63 defective units per million. This is equivalent to an acceptance probability of >99.99%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.