The electrochemical oxidation of piroxicam (PIR), a representative nonsteroidal anti-inflammatory drug, was studied using boron-doped diamond (BDD) as anode. BDD exhibited superior efficiency in comparison with platinum electrodes in terms of PIR degradation. Removal of PIR follows pseudo-first-order kinetics and the apparent kinetic constants decreased from 0.138 to 0.0369 min À 1 as the initial PIR concentration increased from 245 to 975 μg L À 1 . Altering of the pH had little effect on electrolysis of PIR with slightly better removal at pH 9. The presence of 10 g L À 1 of tert-butanol inhibited PIR removal, indicating that its oxidation is caused by electro-generated hydroxyl radicals. Addition of 200 mg L À 1 sodium chloride increased the apparent kinetic constant more than ten times from 0.139 to 1.44 min À 1 . Similar behavior was observed in the case of bicarbonates and nitrates, possibly due to the generation of selective carbonate radicals and active oxygen species like nitric or nitrous oxides. Experiments were also conducted in various aqueous matrices and it was observed that the presence of humic acid delayed the degradation of PIR, while process efficiency was enhanced in bottled and surface water as well as in wastewater, due to the presence of inorganic ions. Coupling BDD electrolysis with ultrasound (at 14 W L À 1 , 20 kHz) increased the reaction rate of PIR destruction and the observed synergy was calculated at S = 44.6 %. order to keep temperature of the water below 35°C after 15 min of sonoelectrocatalysis. Liquid ChromatographyPIR was detected by modifying an HPLC method, described in our previous work. [48] The chromatographic system was a Waters Alliance 2695 connected with a Waters 2996 PDA detector. The column was a Kinetex XB-C18 100A column (2.6 μm, 2.1 mm × 150 mm and was connected with a 0.5 μm inline filter (KrudKatcher Ultra) (Phenomenex). The flow rate was 0.2 mL/min and the mobile phase consisted of 75 : 25 acetonitrile water. The column was thermostated to 45°C. The injection volume was 100 μL. After the separation, the concentration of PIR was measured using Waters 2996 Photo Diode Array detector at 350 nm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.