Purpose To conduct an in vitro comparison of the amount of three‐dimensional (3D) deviation of 3D printed casts generated from digital implant impressions with an intraoral scanner (IOS) to stone casts made of conventional impressions. Material and Methods A maxillary master cast with partially edentulous anterior area was fabricated with two internal connection implants (Regular CrossFit, Straumann). Stone casts (n = 10) that served as a control were fabricated with the splinted open‐tray impression technique. Twenty digital impressions were made using a white light IOS (TRIOS, 3shape) and the Standard Tesselation Language (STL) files obtained were saved. Based on the STL files, a digital light processing (DLP) and a stereolithographic (SLA) 3D printer (Varseo S and Form 2) were used to print casts (n = 10 from each 3D printer). The master cast and all casts generated from each group were digitized using the same IOS. The STL files obtained were superimposed on the master cast STL file (reference) to evaluate the amount of 3D deviation with inspection software using the root mean square value (RMS). The independent‐samples Kruskal‐Wallis test and Dunn's test with Bonferroni correction (for post hoc comparisons) were used for statistical analyses. Results The Varseo S group had the lowest median RMS value [77.5 µm (IQR = 91.4‐135.4)], followed closely by the Conventional group [77.7 µm (IQR = 61.5‐93.4)]. The Form 2 had the highest mean value [98.8 µm (IQR = 57.6‐87.9)]. The independent‐samples Kruskal‐Wallis test revealed a significant difference between the groups (p = 0.018). Post hoc testing revealed a significant difference between Varseo S and Form 2 (p = 0.009). Conclusion The casts generated from the Varseo S 3D printer had better 3D accuracy than did those from the Form 2 3D printer. Both the Varseo S group and the conventional stone casts groups had similar 3D accuracy.
Objective To compare in vitro the accuracy of fit of a reference prosthesis seated on three‐dimensional (3D) printed casts generated from digital implant scans vs stone casts made by conventional implant impressions. Material and Methods A partially edentulous maxillary master cast with two internal connection implants was generated, while a reference implant‐supported prosthesis was fabricated. Conventional splinted open‐tray impressions were taken to create stone casts (n = 10) (control group). A digital scan was taken of the master cast using a white light intraoral optical scanner (IOS) (TRIOS, 3Shape), and a Standard Tessellation Language (STL) file was obtained. Four 3D printers were used to print the casts (n = 10 from each 3D printer): Straumann® P30+, Varseo S, Form 3b+and M2 Carbon. Accuracy of fit of the reference prosthesis on all control and test casts was assessed using the screw resistance test and radiographic test. Additionally, all casts were digitized using the same IOS, and the STL files were superimposed to the master cast STL file (reference) to evaluate the 3D accuracy with inspection Geomagic Control software using the root‐mean‐square (RMS) error. Results The reference prosthesis presented with clinically acceptable fit on all casts. The highest median RMS error was found in the stone cast group (94.6 μm) while the lowest median was in the M2 Carbon group (46.9 μm). The Kruskal–Wallis test revealed a statistically significant difference between the groups (p < 0.001). For post hoc comparisons, Dunn's test with the Holm–Bonferroni correction resulted in a statistically significant difference in four tests, with M2 Carbon exhibiting lower RMS error than the stone cast (p < 0.001) and P30+ (p < 0.001) groups, Form 3b exhibiting lower RMS error than the stone cast (p < 0.001) group, and Varseo S exhibiting lower RMS error than the stone cast (p = 0.006) group. Conclusion Using the screw‐resistance test and radiographic assessment, the reference prosthesis fit presented with clinically acceptable accuracy of fit on all casts. Printed casts from 3 different printers demonstrated statistically significant lower 3D deviations than stone casts generated using a conventional implant impression for the present partially edentulous scenario with two implants, but this did not affect prosthesis fit. Clinical Significance Even though there were 3D deviations between the master cast and all control and test casts generated from conventional impressions and digital scans respectively, the reference prosthesis presented with accurate fit on all casts. This indicates that there is a threshold for clinically acceptable accuracy of fit and that 3D‐printed casts may be used as definitive master casts to fabricate implant‐supported fixed dental prostheses for the partially edentulous anterior maxilla.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.