Upper limb prostheses are increasingly resembling the limbs they seek to replace in both form and functionality, including the design and development of multifingered hands and wrists. Hence, it becomes necessary to control large numbers of degrees of freedom (DOFs), required for individuated finger movements, preferably using noninvasive signals. While existing control paradigms are typically used to drive a single-DOF hook-based configurations, dexterous tasks such as individual finger movements would require more elaborate control schemes. We show that it is possible to decode individual flexion and extension movements of each finger (ten movements) with greater than 90% accuracy in a transradial amputee using only noninvasive surface myoelectric signals. Further, comparison of decoding accuracy from a transradial amputee and able-bodied subjects shows no statistically significant difference ( p < 0.05) between these subjects. These results are encouraging for the development of real-time control strategies based on the surface myoelectric signal to control dexterous prosthetic hands.
A collaborative framework was initiated to establish a community resource of ground truth segmentations from cardiac MRI. Multi-site, multi-vendor cardiac MRI datasets comprising 95 patients (73 men, 22 women; mean age 62.73 ± 11.24 years) with coronary artery disease and prior myocardial infarction, were randomly selected from data made available by the Cardiac Atlas Project (Fonseca et al., 2011). Three semi- and two fully-automated raters segmented the left ventricular myocardium from short-axis cardiac MR images as part of a challenge introduced at the STACOM 2011 MICCAI workshop (Suinesiaputra et al., 2012). Consensus myocardium images were generated based on the Expectation-Maximization principle implemented by the STAPLE algorithm (Warfield et al., 2004). The mean sensitivity, specificity, positive predictive and negative predictive values ranged between 0.63-0.85, 0.60-0.98, 0.56-0.94 and 0.83-0.92, respectively, against the STAPLE consensus. Spatial and temporal agreement varied in different amounts for each rater. STAPLE produced high quality consensus images if the region of interest was limited to the area of discrepancy between raters. To maintain the quality of the consensus, an objective measure based on the candidate automated rater performance distribution is proposed. The consensus segmentation based on a combination of manual and automated raters were more consistent than any particular rater, even those with manual input. The consensus is expected to improve with the addition of new automated contributions. This resource is open for future contributions, and is available as a test bed for the evaluation of new segmentation algorithms, through the Cardiac Atlas Project (www.cardiacatlas.org).
The fast pace of development of upper-limb prostheses requires a paradigm shift in EMG-based controls. Traditional control schemes are only capable of providing 2 degrees of freedom, which is insufficient for dexterous control of individual fingers. We present a framework where myoelectric signals from natural hand and finger movements can be decoded with a high accuracy. 32 surface-EMG electrodes were placed on the forearm of an able-bodied subject while performing individual finger movements. Using time-domain feature extraction methods as inputs to a neural network classifier, we show that 12 individuated flexion and extension movements of the fingers can be decoded with an accuracy higher than 98%. To our knowledge, this is the first instance in which such movements have been successfully decoded using surface-EMG. These preliminary findings provide a framework that will allow the results to be extended to non-invasive control of the next generation of upper-limb prostheses for amputees.
BackgroundCardiovascular magnetic resonance (CMR) myocardial native T1 mapping allows assessment of interstitial diffuse fibrosis. In this technique, the global and regional T1 are measured manually by drawing region of interest in motion-corrected T1 maps. The manual analysis contributes to an already lengthy CMR analysis workflow and impacts measurements reproducibility. In this study, we propose an automated method for combined myocardium segmentation, alignment, and T1 calculation for myocardial T1 mapping.MethodsA deep fully convolutional neural network (FCN) was used for myocardium segmentation in T1 weighted images. The segmented myocardium was then resampled on a polar grid, whose origin is located at the center-of-mass of the segmented myocardium. Myocardium T1 maps were reconstructed from the resampled T1 weighted images using curve fitting. The FCN was trained and tested using manually segmented images for 210 patients (5 slices, 11 inversion times per patient). An additional image dataset for 455 patients (5 slices and 11 inversion times per patient), analyzed by an expert reader using a semi-automatic tool, was used to validate the automatically calculated global and regional T1 values. Bland-Altman analysis, Pearson correlation coefficient, r, and the Dice similarity coefficient (DSC) were used to evaluate the performance of the FCN-based analysis on per-patient and per-slice basis. Inter-observer variability was assessed using intraclass correlation coefficient (ICC) of the T1 values calculated by the FCN-based automatic method and two readers.ResultsThe FCN achieved fast segmentation (< 0.3 s/image) with high DSC (0.85 ± 0.07). The automatically and manually calculated T1 values (1091 ± 59 ms and 1089 ± 59 ms, respectively) were highly correlated in per-patient (r = 0.82; slope = 1.01; p < 0.0001) and per-slice (r = 0.72; slope = 1.01; p < 0.0001) analyses. Bland-Altman analysis showed good agreement between the automated and manual measurements with 95% of measurements within the limits-of-agreement in both per-patient and per-slice analyses. The intraclass correllation of the T1 calculations by the automatic method vs reader 1 and reader 2 was respectively 0.86/0.56 and 0.74/0.49 in the per-patient/per-slice analyses, which were comparable to that between two expert readers (=0.72/0.58 in per-patient/per-slice analyses).ConclusionThe proposed FCN-based image processing platform allows fast and automatic analysis of myocardial native T1 mapping images mitigating the burden and observer-related variability of manual analysis.Electronic supplementary materialThe online version of this article (10.1186/s12968-018-0516-1) contains supplementary material, which is available to authorized users.
Optic Disc (OD) localization is an important pre-processing step that significantly simplifies subsequent segmentation of the OD and other retinal structures. Current OD localization techniques suffer from impractically-high computation times (few minutes per image). In this work, we present a fast technique that requires less than a second to localize the OD. The technique is based upon obtaining two projections of certain image features that encode the x- and y- coordinates of the OD. The resulting 1-D projections are then searched to determine the location of the OD. This avoids searching the 2-D image space and, thus, enhances the speed of the OD localization process. Image features such as retinal vessels orientation and the OD brightness are used in the current method. Four publicly-available databases, including STARE and DRIVE, are used to evaluate the proposed technique. The OD was successfully located in 330 images out of 340 images (97%) with an average computation time of 0.65 s.
Background Hypertensive heart disease (HHD) and hypertrophic cardiomyopathy (HCM) are both associated with an increased left ventricular (LV) wall thickness. Whilst LV ejection fraction is frequently normal in both, LV strain assessment could differentiate between the diseases. We sought to establish if cardiovascular magnetic resonance myocardial feature tracking (CMR-FT), an emerging method allowing accurate assessment of myocardial deformation, differentiates between both diseases. Additionally, CMR assessment of fibrosis and LV hypertrophy allowed association analyses and comparison of diagnostic capacities. Methods Two-hundred twenty-four consecutive subjects (53 HHD, 107 HCM, and 64 controls) underwent 1.5T CMR including native myocardial T 1 mapping and late gadolinium enhancement (LGE). Global longitudinal strain (GLS) was assessed by CMR-FT (CVi42, Circle Cardiovascular Imaging Inc.). Results GLS was significantly higher in HCM patients (-14.7±3.8 vs. -16.5±3.3% [HHD], P = 0.004; or vs. -17.2±2.0% [controls], P<0.001). GLS was associated with LV mass index (HHD, R = 0.419, P = 0.002; HCM, R = 0.429, P<0.001), and LV ejection fraction (HHD, R = -0.493, P = 0.002; HCM, R = -0.329, P<0.001). In HCM patients, GLS was also associated with global native T 1 (R = 0.282, P = 0.003), and LGE volume (ρ = 0.380, P<0.001). Discrimination between HHD and HCM by GLS (c = 0.639, 95% confidence interval [CI] 0.550–0.729) was similar to LV mass index (c = 0.643, 95% CI 0.556–0.731), global myocardial native T 1 (c = 0.718, 95% CI 0.638–0.799), and LGE volume (c = 0.680, 95% CI 0.585–0.775). Conclusion CMR-FT GLS differentiates between HHD and HCM. In HCM patients GLS is associated with myocardial fibrosis. The discriminatory capacity of CMR-FT GLS is similar to LV hypertrophy and fibrosis imaging markers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.