Type-D personality but not ICD indication was associated with impaired HRQL at the time of implantation and at 3 months. In the quest for enhancing risk stratification in clinical practice, personality factors, such as type-D, should not be ignored, as both type-D and poor HRQL have been associated with increased risk of mortality in cardiac patients.
BackgroundImplantable cardioverter-defibrillators (ICDs) reduce mortality in both primary and secondary prevention, but are associated with substantial short- and long-term morbidity. A totally subcutaneous ICD (S-ICD) system has been developed. We report the initial clinical experience of the first 31 patients implanted at our hospital.MethodsAll patients had an ICD indication according to the ACC/AHA/ESC guidelines. The first 11 patients were part of the reported CE trial. The implantation was performed without fluoroscopy. The device was implanted subcutaneously in the anterior axillary line, with a parasternal lead tunneled from the xiphoid to the manubrial–sternal junction. Ventricular fibrillation (VF) was induced to assess detection accuracy and defibrillation efficacy using 65 J shocks.ResultsPost-implant, 52 sustained episodes of VF were induced. Sensitivity was 100% and induced conversion efficacy was 100% (with standard polarity in 29 patients). Mean time to therapy was 13.9 ± 2.5 s (range 11–21.6 s). Late procedure-related complications were observed in 2 of the first 11 implantations (lead migration). During follow-up, spontaneous ventricular arrhythmias occurred in four patients, with accurate detection of all episodes. Inappropriate therapy was observed in five patients. Recurrences were prevented with reprogramming.ConclusionsThe S-ICD system can be implanted without the use of fluoroscopy by using anatomical landmarks only. Episodes of VF were accurately detected using subcutaneous signals, and all induced and clinical episodes were successfully converted. The S-ICD system is a viable alternative to conventional ICD systems for selected patients.
BackgroundThe benefit of implantable defibrillators (ICDs) for primary prevention remains debated. We analysed the implications of prophylactic ICD implantation according to the guidelines in 2 tertiary hospitals, and made a healthcare utilisation inventory.MethodsThe cohort consisted of all consecutive patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM) receiving a primary prophylactic ICD in a contemporary setting (2004–2008). Follow-up was obtained from hospital databases, and mortality checked at the civil registry. Additional data came from questionnaires sent to general practitioners.ResultsThere were no demographic differences between the 2 centres; one had proportionally more CAD patients and more resynchronisation therapy (CRT-D). The 587 patients were followed over a median of 28 months, and 50 (8.5%) patients died. Appropriate ICD intervention occurred in 123 patients (21%). There was a small difference in intervention-free survival between the 2 centres. The questionnaires revealed 338 hospital admissions in 52% of the responders. Device-related admissions happened on 68 occasions, in 49/276 responders. The most frequently reported ICD-related admission was due to shocks (20/49 patients); for other cardiac problems it was mainly heart failure (52/99). Additional outpatient visits occurred in 19%.ConclusionOver a median follow-up of 2 years, one fifth of prophylactic ICD patients receive appropriate interventions. A substantial group undergoes readmission and additional visits. The high number of admissions points to a very ill population. Overall mortality was 8.5%. The 2 centres employed a similar procedure with respect to patient selection. One centre used more CRT-D, and observed more appropriate ICD interventions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.